Monitoring and Maintenance of CP System in MGL

被引:0
|
作者
Duraisamy, Kokila [1 ]
机构
[1] Mahanagar Gas Ltd, Mumbai, Maharashtra, India
关键词
Cathodic protection; City gas distribution; pipeline maintenance; integrity assessment;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Mahanagar Gas Limited is a City Gas distribution (CGD) company based out of the city of Mumbai and around. MGL currently has around 480 Kms of Steel gas pipelines for transportation of natural gas. The diameters of these pipelines are ranging from 2 '' to 18 '' and almost all are coated with 3 layer Poly Ethylene coating (3LPE). We are installing Permanent Cathodic Protection (PCP) for all commissioned pipelines and Temporary Cathodic Protection (TCP) having a design life of 5 years for un-commissioned pipelines during the projects stage itself. This paper shall basically outline the CP system in MGL along with various practices being followed in MGL to ascertain the effectiveness of CP. MGL has installed various CP assets like CP stations, Diode stations, external ER probes , corrosion coupons to ascertain the CP effectiveness. This paper shall outline the detailed monitoring procedure along with monitoring frequency of all the assets. MGL is also carrying out health adequacy surveys like DCVG, CIPL etc over the steel pipeline network. Few case studies arising out of these monitoring results shall be presented in this paper. (1) Casing carrier short at Taloja Railway crossing. The detailed procedure of monitoring and rectification shall be presented. (2) Case study on CP under-protection at Andheri which was resolved using a flange isolation kit.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] CP cuts pipeline maintenance costs
    Stephens, Ralph W.
    Gas Industries (Park Ridge, Illinois), 1996, 40 (12):
  • [22] Monitoring and maintenance
    不详
    ZKG INTERNATIONAL, 2007, 60 (08): : 40 - 41
  • [23] Maintenance Oriented Condition Monitoring and Fault Diagnosis Expert System for Excitation System
    Zeng Hongtao
    Liu Yajin
    Xiao Zhihuai
    Guo Jiang
    Tian Zhihu
    DCABES 2008 PROCEEDINGS, VOLS I AND II, 2008, : 371 - +
  • [24] AN EXPERT-SYSTEM-BASED MACHINE MONITORING AND MAINTENANCE MANAGEMENT-SYSTEM
    STREICHFUSS, M
    BURGWINKEL, P
    CONTROL ENGINEERING PRACTICE, 1995, 3 (07) : 1023 - 1027
  • [25] Unsupervised Monitoring System for Predictive Maintenance of High Voltage Apparatus
    Gianoglio, Christian
    Ragusa, Edoardo
    Bruzzone, Andrea
    Gastaldo, Paolo
    Zunino, Rodolfo
    Guastavino, Francesco
    ENERGIES, 2020, 13 (05)
  • [26] Remote Data Monitoring Improves Distribution System Efficiency and Maintenance
    Feffer, Adam
    Opflow, 2016, 42 (02) : 10 - 14
  • [27] Customised active monitoring system for structural control and maintenance optimisation
    Chiaia, Bernardino
    Marasco, Giulia
    Ventura, Giulio
    Quirini, Cristina Zannini
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2020, 10 (02) : 267 - 282
  • [28] A Study of the Impact of Predictive Maintenance Parameters on the Improvment of System Monitoring
    Louhichi, Rim
    Sallak, Mohamed
    Pelletan, Jacques
    MATHEMATICS, 2022, 10 (13)
  • [29] Customised active monitoring system for structural control and maintenance optimisation
    Chiaia, Bernardino
    Marasco, Giulia
    Ventura, Giulio
    Zannini Quirini, Cristina
    Journal of Civil Structural Health Monitoring, 2020, 10 (02): : 267 - 282
  • [30] Development of a defect monitoring system (DMOSYS) for building maintenance at polytechnic
    Bin Ismail, Zul-Atfi
    FACILITIES, 2018, 36 (7-8) : 403 - 422