New transient simplified model for radiant heating slab surface temperature and heat transfer rate calculation

被引:9
|
作者
Merabtine, Abdelatif [1 ,2 ]
Mokraoui, Salim [3 ]
Kheiri, Abdelhamid [4 ]
Dars, Anass [2 ]
机构
[1] Univ Reims, GRESPI, Campus Moulin Housse, F-51687 Reims, France
[2] EPF Sch Engn, 2 Rue Fernand Sastre, F-10430 Rosieres Pres Troyes, France
[3] King Saud Univ Riyadh, Chem Engn Dept, Coll Engn, Riyadh, Saudi Arabia
[4] Univ Lorraine, CNRS, Lemta, Nancy, France
关键词
floor heating system; analytical model; time constant; delay time; 2D finite difference; design of experiments; thermal inertia; FLOOR; SIMULATION; SYSTEM; VALIDATION; BEHAVIOR;
D O I
10.1007/s12273-018-0492-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new simplified model based on a semi-analytical correlation is proposed in this paper to evaluate the heating radiant slab surface temperature and to examine its thermal behavior under dynamic solicitations. In fact, the surface temperature is a normative design parameter and shall be kept under an upper limit whatever are the running conditions. Experimental measurements and a two-dimensional finite difference model (2D FDM) were carried out to validate the developed simplified model based on two characteristic parameters that are the time constant and the delay time. A Design of Experiments (DoE) method is employed to derive meta-models for the time constant and the delay time in order to compute the surface temperature. The sensitivity analysis shows that the specific heat capacity of the slab material and the heating water flow rate affect significantly the time constant compared to the thermal conductivity and the heating water pipe inner diameter. Moreover, it was found that all these parameters, except the heating water flow rate, have a substantial impact on the delay time. Compared to the experimental results, the maximum relative deviations from the computed surface temperature are within 2.4% for the numerical model and 1.75% for the simplified semi-analytical model. Consequently, the proposed simplified model may be utilized by engineers and designers to quickly estimate the radiant slab surface temperature and heat flux as well as to study its thermal behavior under dynamic running conditions. This model may also be integrated in the thermal building simulation software.
引用
收藏
页码:441 / 452
页数:12
相关论文
共 50 条
  • [41] A new model for transient heat transfer model on external steel elements
    Chica, J. A.
    Morente, F.
    STEEL AND COMPOSITE STRUCTURES, 2008, 8 (03): : 201 - 216
  • [42] Calculation of Transient Temperature and Thermal Stresses at Calculus of Heat Transfer Coefficient Considering the Radiation
    Gorbunov, A. D.
    Ukleina, S. V.
    PROBLEMELE ENERGETICII REGIONALE, 2016, (01): : 78 - 83
  • [43] A SIMPLIFIED METHOD FOR CALCULATING TRANSIENT AVERAGE TEMPERATURE AND HEAT-TRANSFER IN A LATERALLY HEATED CAVITY
    POUJOL, F
    RAMOS, E
    ROJAS, J
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (03): : 784 - 786
  • [44] Establishment and experimental validation of a dynamic heat transfer model for concrete radiant cooling slab based on reaction coefficient method
    Tian, Zhe
    Duan, Baodong
    Niu, Xiaolei
    Hu, Qi
    Niu, Jide
    ENERGY AND BUILDINGS, 2014, 82 : 330 - 340
  • [45] Establishment and experimental validation of a dynamic heat transfer model for concrete radiant cooling slab based on reaction coefficient method
    Tian, Zhe
    Duan, Baodong
    Niu, Xiaolei
    Hu, Qi
    Niu, Jide
    Energy and Buildings, 2014, 82 : 330 - 340
  • [46] A transient heat transfer model for high temperature solar thermochemical reactors
    Li, Like
    Chen, Chen
    Singh, Abhishek
    Rahmatian, Nima
    AuYeung, Nick
    Randhir, Kelvin
    Mei, Renwei
    Klausner, James F.
    Hahn, David W.
    Petrasch, Joerg
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (04) : 2307 - 2325
  • [47] Accuracy verification of simplified calculation method for moisture sorption with external wall performance test house: Simplified numerical model of moisture transfer on interior surfaces for transient room temperature and heat load calculation of multiple zone buildings part 2
    Hosokawa, Takayuki
    Hayashi, Tetsuo
    Yoshimura, Junichi
    Journal of Environmental Engineering, 2008, 73 (633) : 1291 - 1297
  • [48] A simplified model of heat transfer at an indoor window glazing surface with a Venetian blind
    Roeleveld, Derek
    Naylor, David
    Oosthuizen, Pat
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2010, 3 (02) : 121 - 128
  • [49] THREE DIMENSIONAL TRANSIENT HEAT TRANSFER MODEL FOR STEEL BILLET HEATING IN REHEAT FURNACE
    Dubey, Satish Kumar
    Agarwal, Neelesh
    Srinivasan, P.
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 963 - 967
  • [50] The Establishment and Numerical Calculation of a Heat Transfer Model of a Graphene Heating Energy Storage Floor
    Yang, Chunmei
    Guan, Bo
    Zhang, Zihao
    Zhang, Jiawei
    Xue, Bo
    Tian, Xinchi
    BIORESOURCES, 2023, 18 (01) : 1948 - 1970