Right thoracotomy for aortic valve replacement in the adolescents with bicuspid aortic valve

被引:2
|
作者
Giordano, Raffaele [1 ]
Cantinotti, Massimiliano [2 ,3 ]
Comentale, Giuseppe [1 ]
Di Tommaso, Luigi [1 ]
Iannelli, Gabriele [1 ]
Pilato, Emanuele [1 ]
Palma, Gaetano [1 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Div Adult & Pediat Cardiac Surg, Naples, Italy
[2] Tuscany Fdn G Monasterio CNR Reg Toscana, Massa, Italy
[3] Tuscany Fdn G Monasterio CNR Reg Toscana, Pisa, Italy
关键词
aortic; pediatric cardiac surgery; thoracotomy; RECOMMENDATIONS; MINITHORACOTOMY; MINISTERNOTOMY;
D O I
10.1111/chd.12680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In this study, we compared our experience about early and midterm follow-up outcomes for right anterolateral minithoracotomy (RAMT) vs full sternotomy (FS) in surgical aortic valve replacement (AVR) among adolescents with bicuspid aortic valve (BAV). Methods Patients were retrospectively enrolled from January 2008 to December 2017. Inclusion criteria were patients with BAV who had to undergo to AVR. They were divided in two groups: RAMT and FS. The choice of RAMT was based on individual surgeon's preferences or when expressly requested by patient that was informed of nonconventional approach. Results We enrolled 61 patients, 23 in RAMT group and 38 in FS group. The mean age was 15.6 +/- 1.7 years for RAMT group and 16.1 +/- 1.5 years for FS group (P = .23). The RAMT group had a higher prevalence of female gender (P = .04). The patients in the RAMT group had longer cardiopulmonary bypass (115.2 +/- 18.5 vs 102.2 +/- 16.5 min; P = .006) and cross-clamp time (78.6 +/- 18.1 vs 74.3 +/- 15.2 min; P = .01). No patients required intraoperative conversion to FS. No differences were found in ventilation times, postoperative intensive care unit (ICU), and hospital length of stay for both groups. Follow-up echocardiograms were available for all patients at median of 5.2 years (range 0.5-9.6 years, median 5.4 years for RAMT and 5.1 for FS) and no patient required reoperation for aortic prosthesis malfunction. Conclusions Our study shows that RAMT is safe and effective as FS. Although the RAMT operation takes slightly more operation time, it is not associated with major adverse effects.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [21] Research Progress of Transcatheter Aortic Valve Replacement in Aortic Valve Stenosis due to Bicuspid Aortic Valve
    Chen, Liyan
    Jiang, Li
    Zou, Mei
    Chen, Xuanlan
    Wu, Zhiyong
    HEART SURGERY FORUM, 2024, 27 (04): : E431 - E438
  • [22] Transcatheter and Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis
    Sanaiha, Yas
    Hadaya, Joseph E.
    Tran, Zachary
    Shemin, Richard J.
    Benharash, Peyman
    ANNALS OF THORACIC SURGERY, 2023, 115 (03): : 611 - 618
  • [23] Bicuspid Aortic Valve Morphology and Outcomes After Transcatheter Aortic Valve Replacement
    Yoon, Sung-Han
    Kim, Won-Keun
    Dhoble, Abhijeet
    Pio, Stephan Milhorini
    Babaliaros, Vasilis
    Jilaihawi, Hasan
    Pilgrim, Thomas
    De Backer, Ole
    Bleiziffer, Sabine
    Vincent, Flavien
    Schmidit, Tobias
    Butter, Christian
    Kamioka, Norihiko
    Eschenbach, Lena
    Renker, Matthias
    Asami, Masahiko
    Lazkani, Mohamad
    Fujita, Buntaro
    Birs, Antoinette
    Barbanti, Marco
    Pershad, Ashish
    Landes, Uri
    Oldemeyer, Brad
    Kitamura, Mitusnobu
    Oakley, Luke
    Ochiai, Tomoki
    Chakravarty, Tarun
    Nakamura, Mamoo
    Ruile, Philip
    Deuschl, Florian
    Berman, Daniel
    Modine, Thomas
    Ensminger, Stephan
    Kornowski, Ran
    Lange, Rudiger
    McCabe, James M.
    Williams, Mathew R.
    Whisenant, Brian
    Delgado, Victoria
    Windecker, Stephan
    Van Belle, Eric
    Sondergaard, Lars
    Chevalier, Bernard
    Mack, Michael
    Bax, Jeroen J.
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (09) : 1018 - 1030
  • [24] Valve-sparing aortic replacement - is preservation of a bicuspid aortic valve justified?
    Aicher, D
    Nikoloudakis, N
    Langer, F
    Schaefers, HJ
    Graeter, T
    EUROPEAN HEART JOURNAL, 2001, 22 : 368 - 368
  • [25] Later aorta operation after aortic valve replacement for bicuspid aortic valve
    Hachiro, Kohei
    Takashima, Noriyuki
    Suzuki, Tomoaki
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [26] Predictors of aortic events after aortic valve replacement for bicuspid valve stenosis
    Dayan, Victor
    Pizzano, Nelson
    Cura, Leandro
    Ferreiro, Alejandro
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (02) : 398 - 398
  • [27] Sutureless aortic valve replacement in patients who have bicuspid aortic valve
    Nguyen, Anthony
    Fortin, William
    Mazine, Amine
    Bouchard, Denis
    Carrier, Michel
    El Hamamsy, Ismail
    Lamarche, Yoan
    Demers, Philippe
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (04): : 851 - 857
  • [28] Clinical Outcomes of Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis
    Yoon, Sung-Han
    Lefevre, Thierry
    Dvir, Danny
    Ahn, Jung-Min
    Arai, Takahide
    Kim, Young-Hak
    Watanabe, Yusuke
    Kao, Paul Hsien-Li
    Yong, Gerald
    Yin, Wei-Hsian
    Lee, Michael Kang-Yin
    Tay, Edgar L.
    Kim, Hyo-Soo
    Chevalier, Bernard
    Morice, Marie-Claude
    John, Webb
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B48 - B48
  • [29] Later aorta operation after aortic valve replacement for bicuspid aortic valve
    Kohei Hachiro
    Noriyuki Takashima
    Tomoaki Suzuki
    Journal of Cardiothoracic Surgery, 19
  • [30] Recent Advances in Aortic Valve Disease: Highlights From a Bicuspid Aortic Valve to Transcatheter Aortic Valve Replacement
    Augoustides, John G. T.
    Wolfe, Yanika
    Walsh, Elizabeth K.
    Szeto, Wilson Y.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (04) : 569 - 576