Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging

被引:80
|
作者
Lazaro, D
Buvat, I
Loudos, G
Strul, D
Santin, G
Giokaris, N
Donnarieix, D
Maigne, L
Spanoudaki, V
Styliaris, S
Staelens, S
Breton, V
机构
[1] Univ Clermont Ferrand, CNRS IN2P3, Phys Corpusculaire Lab, F-63177 Aubiere 1, France
[2] CHU Pitie Salpetriere, INSERM U494, F-75634 Paris 13, France
[3] Inst Accelerating Syst & Applicat Athens, Athens 10024, Greece
[4] Univ Athens, Dept Phys, Nucl & Particle Phys Div, Athens 15771, Greece
[5] Univ Lausanne, Inst High Energy Phys, CH-1015 Lausanne, Switzerland
[6] ESA, ESTEC, Noordwijk, Netherlands
[7] Ctr Jean Perrin, Dept Curietherapie Radiotherapie, F-63000 Clermont Ferrand, France
[8] Univ Ghent, ELIS Dept, B-9000 Ghent, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 02期
关键词
D O I
10.1088/0031-9155/49/2/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and Correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(T1) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated Tc-99m point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 mum. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.
引用
收藏
页码:271 / 285
页数:15
相关论文
共 50 条
  • [21] Comparison of photon counting and conventional scintillation detectors in a pinhole SPECT system for small animal imaging: Monte carlo simulation studies
    Young-Jin Lee
    Su-Jin Park
    Seung-Wan Lee
    Dae-Hong Kim
    Ye-Seul Kim
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2013, 62 : 1317 - 1322
  • [22] Ultra-high-resolution SPECT with CdTe for small-animal imaging applications: A Monte Carlo simulation study using a voxelized phantom
    Su-Jin Park
    Chang-Lae Lee
    Hyo-Min Cho
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 60 : 1145 - 1149
  • [23] Ultra-high-resolution SPECT with CdTe for Small-animal Imaging Applications: A Monte Carlo Simulation Study Using A Voxelized Phantom
    Park, Su-Jin
    Lee, Chang-Lae
    Cho, Hyo-Min
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1145 - 1149
  • [24] Monte Carlo simulation study of a dual-plate PET camera dedicated to breast cancer Imaging
    Zhang, Jin
    Olcott, Peter D.
    Foudray, Angela M. K.
    Chinn, Garry
    Levin, Craig S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1667 - 1671
  • [25] GATE Monte Carlo simulation of a high-sensitivity and high-resolution LSO-based small animal PET camera
    Baghaei, Flossain
    Zhang, Yuxuan
    Li, Hongdi
    Wang, Yu
    Kim, Soonseok
    Ramirez, Rocio A.
    Liu, Jiguo
    Liu, Shitao
    Wong, Wai-Hoi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1568 - 1573
  • [26] A GATE Monte Carlo Simulation of the Performance of a High-Sensitivity and High-Resolution LSO Based Small Animal PET Camera
    Baghaei, Hossain
    Zhang, Yuxuan
    Li, Hongdi
    Wang, Yu
    Kim, Soonseok
    Ramirez, Rocio
    Liu, Jiguo
    Liu, Shitao
    Wong, Wai-Hoi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2476 - 2479
  • [27] A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform
    Tryggestad, E.
    Armour, M.
    Iordachita, I.
    Verhaegen, F.
    Wong, J. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17): : 5341 - 5357
  • [28] A novel multi-pinhole/CCD-coupled CsI(Tl) crystal gamma camera for fully 3D μSPECT/μCT small-animal imaging.
    Antich, PP
    Lewis, MA
    Richer, E
    Kulkarni, PV
    Smith, BJ
    Mason, RP
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 161P - 161P
  • [29] Validation of the New GATE 6.0 Monte Carlo Platform for Radiation Therapy. Investigations on Simulation Parameters
    Perrot, Y.
    Donnarieix, D.
    Breton, V.
    Maigne, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Feasibility of Small Animal Anatomical and Functional Imaging with Neutrons: A Monte Carlo Simulation Study
    Medich, David C.
    Currier, Blake H.
    Karellas, Andrew
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2480 - 2488