New sheathless interface for coupling capillary electrophoresis to electrospray mass spectrometry evaluated by the analysis of fatty acids and prostaglandins

被引:31
|
作者
Petersson, MA [1 ]
Hulthe, G [1 ]
Fogelqvist, E [1 ]
机构
[1] Univ Gothenburg, Dept Chem Analyt & Marine Chem, SE-41296 Gothenburg, Sweden
关键词
interfaces; CE-MS; instrumentation; electrospray ionization; capillary electrophoresis-mass spectrometry; prostaglandins; fatty acids;
D O I
10.1016/S0021-9673(99)00615-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new interface for capillary electrophoresis electrospray ionization (CE-ESI) is presented. High voltage is applied at the outlet of the separation capillary by a stainless steel tube, a so called liner, through which the capillary is led. A compensating current between the liquid and the liner is maintained by a natural liquid film, which is built up at the outer surface of the capillary end. Operable potential ranges for differently treated capillary ends have been examined. The liner has been evaluated for the analysis of fatty acids and prostaglandins, all run with the ESI in the negative ionization mode. This simple stainless steel liner should fill the gap, which has prevented CE-MS from being the successful tool, which it has the potential for, namely fast and unattended measurements of analytes in the nM range in complex mixtures. (C) 1999 Elsevier Science BN. All rights reserved.
引用
收藏
页码:141 / 154
页数:14
相关论文
共 50 条
  • [21] Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates
    Bindila, L
    Peter-Katalinic, J
    Zamfir, A
    ELECTROPHORESIS, 2005, 26 (7-8) : 1488 - 1499
  • [22] A gold foil covered fused silica capillary tip as a sheathless interface for coupling capillary electrophoresis-mass spectrometry
    Zhang, Hanzhi
    Lou, Chunli
    Li, Jing
    Kang, Jingwu
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [23] Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary
    Chang, YZ
    Her, GR
    ANALYTICAL CHEMISTRY, 2000, 72 (03) : 626 - 630
  • [24] Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry
    Tong, Ping
    Zhang, Lan
    He, Yu
    Tang, Shurong
    Cheng, Jintian
    Chen, Guonan
    TALANTA, 2010, 82 (04) : 1101 - 1106
  • [25] Optimization of capillary electrophoresis conditions for coupling to a mass spectrometer via a sheathless interface
    Samskog, J
    Wetterhall, M
    Jacobsson, S
    Markides, K
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (07): : 919 - 924
  • [26] The development of a sheathless capillary electrophoresis electrospray ionization-mass spectrometry interface based on thin conducting liquid film
    Huang, Ju-Li
    Hsu, Ren-Yu
    Her, Guor-Rong
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 131 - 137
  • [27] Sheathless capillary electrophoresis/electrospray ionization mass spectrometry using a pulled bare fused-silica capillary as the electrospray emitter
    Wu, YT
    Chen, YC
    ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2071 - 2077
  • [28] A new high-performance interface for capillary electrophoresis electrospray ionization mass spectrometry
    Severs, JC
    Harms, AC
    Smith, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (10) : 1175 - 1178
  • [29] A New High-performance Interface for Capillary Electrophoresis/Electrospray Ionization Mass Spectrometry
    Severs, J. C.
    Harms, A. C.
    Smith, R. D.
    Rapid Communications in Mass Spectrometry, 10 (10):
  • [30] Analysis of peptides, proteins, protein digests, and whole human blood by capillary electrophoresis electrospray ionization mass spectrometry using an in-capillary electrode sheathless interface
    Cao, P
    Moini, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (10) : 1081 - 1088