Liquid chromatography-electrospray mass spectrometry determination of free and total concentrations of ropivacaine in human plasma

被引:18
|
作者
Mathieu, O
Hillaire-Buys, D
Dadure, C
Barnay, F
Mathieu-Daudé, JC
Bressolle, F
机构
[1] Univ Montpellier I, Fac Pharm, Clin Pharmacokinet Lab, F-34093 Montpellier 5, France
[2] Lapeyronie Hosp, Intens Care Unit, Montpellier, France
[3] Arnaud de Villeneuve Hosp, INSERM, U454, Montpellier, France
[4] Lapeyronie Hosp, Dept Med Pharmacol & Toxicol, Montpellier, France
关键词
ropivacaine; local anaesthetics; equilibrium-dialysis; plasma; quantitation LC-ESI-MS;
D O I
10.1016/j.jchromb.2005.11.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A specific and sensitive liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the determination of free and total ropivacaine in human plasma. The work-up procedure involved a simple precipitation of plasma proteins with methanol. Etidocaine served as the internal standard. After microscale equilibrium-dialysis, measurement of free ropivacaine levels was performed after direct injection of the dialysate into the chromatograph. The system used a Zorbax eclipse XD8 C8 analytical column packed with 5 mu m diameter particles as the stationary phase. The mobile phase consisted of a 15-min gradient (mobile phase A: 0.05% (v/v) trimethylamine in acetonitrile, mobile phase 13: 2 mM ammonium formate buffer (pH 3)). Mass spectrometric data were acquired in single ion monitoring mode at m/z 275 for ropivacaine and m/z 277 for etidocaine. The drug/internal standard peak area ratios (plasma) or peak areas (dialysate) were linked via a quadratic relationship to concentrations. Precision ranged from I to 7.6% and accuracy was between 92.6 and 109%. The lower limits of quantitation were 1 mu g/1 in plasma and 2 mu g/l in the dialysate. This method was found suitable for the analysis of plasma samples collected during a clinical trial performed in 30 infants undergoing epidural anaesthesia or continuous psoas compartment block. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [21] Quantitation of Armillarisin A in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Wang, Yan
    Wang, Yingwu
    Li, Pengfei
    Tang, Yunbiao
    Fawcett, J. Paul
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1860 - 1863
  • [22] Quantification of acarbose in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Raut, BB
    Kolte, BL
    Deo, AA
    Bagool, MA
    Shinde, DB
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (11) : 1759 - 1768
  • [23] Determination of gestrinone in human serum by liquid chromatography-electrospray tandem mass spectrometry
    Wang, QG
    Wu, ZP
    Wang, YM
    Luo, GA
    Wu, E
    Gao, XF
    JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (02): : 151 - 159
  • [24] Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Ding, L
    Li, LM
    Tao, P
    Yang, J
    Zhang, ZX
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 75 - 81
  • [25] Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry
    Thompson, RQ
    Phinney, KW
    Welch, MJ
    White, VE
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (07) : 1441 - 1451
  • [26] Determination of glucosinolates in rapeseeds by liquid chromatography-electrospray mass spectrometry
    Guo, WQ
    Yuan, LF
    Chen, P
    Guo, JJ
    ANALYTICAL LETTERS, 2005, 38 (03) : 343 - 351
  • [27] Determination of orneprazole in human plasma by liquid chromatography-electrospray quadrupole linear ion trap mass spectrometry
    Wang, J
    Wang, YW
    Fawcett, JP
    Wang, Y
    Gu, JK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 631 - 635
  • [28] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [29] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [30] Determination of raltitrexed in human plasma by high performance liquid chromatography-electrospray ionization-mass spectrometry
    Hu, Jingjing
    Ding, Li
    Song, Qinxin
    Gao, Ying
    Qing, Shukui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 147 - 153