Liquid chromatography-electrospray mass spectrometry determination of free and total concentrations of ropivacaine in human plasma

被引:18
|
作者
Mathieu, O
Hillaire-Buys, D
Dadure, C
Barnay, F
Mathieu-Daudé, JC
Bressolle, F
机构
[1] Univ Montpellier I, Fac Pharm, Clin Pharmacokinet Lab, F-34093 Montpellier 5, France
[2] Lapeyronie Hosp, Intens Care Unit, Montpellier, France
[3] Arnaud de Villeneuve Hosp, INSERM, U454, Montpellier, France
[4] Lapeyronie Hosp, Dept Med Pharmacol & Toxicol, Montpellier, France
关键词
ropivacaine; local anaesthetics; equilibrium-dialysis; plasma; quantitation LC-ESI-MS;
D O I
10.1016/j.jchromb.2005.11.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A specific and sensitive liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the determination of free and total ropivacaine in human plasma. The work-up procedure involved a simple precipitation of plasma proteins with methanol. Etidocaine served as the internal standard. After microscale equilibrium-dialysis, measurement of free ropivacaine levels was performed after direct injection of the dialysate into the chromatograph. The system used a Zorbax eclipse XD8 C8 analytical column packed with 5 mu m diameter particles as the stationary phase. The mobile phase consisted of a 15-min gradient (mobile phase A: 0.05% (v/v) trimethylamine in acetonitrile, mobile phase 13: 2 mM ammonium formate buffer (pH 3)). Mass spectrometric data were acquired in single ion monitoring mode at m/z 275 for ropivacaine and m/z 277 for etidocaine. The drug/internal standard peak area ratios (plasma) or peak areas (dialysate) were linked via a quadratic relationship to concentrations. Precision ranged from I to 7.6% and accuracy was between 92.6 and 109%. The lower limits of quantitation were 1 mu g/1 in plasma and 2 mu g/l in the dialysate. This method was found suitable for the analysis of plasma samples collected during a clinical trial performed in 30 infants undergoing epidural anaesthesia or continuous psoas compartment block. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [1] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [2] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 103 - 109
  • [3] Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Jiang, Yao
    Wang, Jiang
    Li, Hao
    Wang, Yingwu
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1460 - 1464
  • [4] Determination of flumazenil in human plasma by liquid chromatography-electrospray ionisation tandem mass spectrometry
    Lavén, M
    Appel, L
    Moulder, R
    Tyrefors, N
    Markides, K
    Långström, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02): : 221 - 227
  • [5] Quantitative determination of rocuronium in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Farenc, C
    Enjalbal, C
    Sanchez, P
    Bressolle, F
    Audran, M
    Martinez, J
    Aubagnac, JL
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) : 61 - 67
  • [6] Determination of palonosetron in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Ding, Li
    Chen, Yan
    Yang, Lin
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 575 - 580
  • [7] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320
  • [8] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Kim, HY
    Chang, KY
    Lee, HJ
    Han, SB
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (01) : 109 - 114
  • [9] Determination of limonin in rat plasma by liquid chromatography-electrospray mass spectrometry
    Liang, Y
    Xie, L
    Liu, XD
    Lu, T
    Hu, YZ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (05) : 1031 - 1035
  • [10] DETERMINATION OF NORDIHYDROCAPSAICIN IN RABBIT PLASMA BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY MASS SPECTROMETRY
    Lin, Guanyang
    Ma, Jianshe
    Lin, Chongliang
    Hu, Lufeng
    Wang, Xianqin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (17) : 2506 - 2514