Performance Evaluation of Double Effect Solar Still

被引:0
|
作者
Dave, Chinmay [1 ]
Maiti, Subarna [2 ]
Markam, Bhupendra Kumar [2 ]
Patel, Pankaj [1 ,2 ]
Patel, Jatin
机构
[1] Pandit Deendayal Petr Univ, Gandhinagar 382007, Gujarat, India
[2] CSIR, Cent Salt & Marine Chem Res Inst, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
关键词
Solar desalination; Double effect still; Continuous flow;
D O I
10.1007/978-981-10-4576-9_21
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Development of different useful decentralised solar gadgets is possible due to the abundant solar thermal radiation available particularly in the western part of India. Desalination is one technique to use this energy to produce distilled water using solar stills. More so, even highly saline water can be treated using solar stills. The output of conventional basin type solar still is only 1-2 LPD. In this, the latent heat of condensation is transferred to the surrounding and wasted. To use the latent heat and enhance the output a double effect type of solar still with two basins is fabricated in this work. A cotton cloth is kept on top of the lower basin to make a thin-film layer of continuously flowing water. Hot water is supplied to the lower basin through solar flat plate collector. It is seen that with increasing salt concentration in feed water results in a reduction of product output from a conventional still, but, in the modified double effect still, the product output remains the same.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 50 条
  • [21] PERFORMANCE OF A DOUBLE CONDENSING MULTIPLE WICK SOLAR-STILL
    TIWARI, GN
    SHARMA, SB
    SODHA, MS
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (02) : 155 - 159
  • [22] Enhancing the design to optimize the performance of double basin solar still
    Gnanaraj, S. Joe Patrick
    Ramachandran, S.
    Christopher, David Santosh
    DESALINATION, 2017, 411 : 112 - 123
  • [23] Performance analysis of double basin solar still with evacuated tubes
    Panchal H.N.
    Shah P.K.
    Applied Solar Energy, 2013, 49 (3) : 174 - 179
  • [24] Augmentation and evaluation of solar still performance: A comprehensive review
    Elsheikh, Ammar
    Hammoodi, Karrar A.
    Ibrahim, Ahmed Mohamed Mahmoud
    Mourad, Abdel-Hamid I.
    Fujii, Manabu
    Abd-Elaziem, Walaa
    DESALINATION, 2024, 574
  • [25] Performance Evaluation of an Enhanced Solar Still Using Simulink
    Naidu, Vimal Dev
    Mustapha, Mazli B.
    Gilani, Syed I. U.
    JOURNAL OF ELECTRICAL SYSTEMS, 2024, 20 (05) : 1204 - 1216
  • [26] Performance evaluation of a solar still for industrial wastewater treatment
    Ojo, Ochuko M.
    Obiora-Okeke, Obinna A.
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : S1 - S6
  • [27] Performance evaluation of a vertical rotating wick solar still
    Omara, Z. M.
    Abdullah, A. S.
    Essa, F. A.
    Younes, M. M.
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 148 : 796 - 804
  • [28] Design, fabrication and performance evaluation of a hybrid photovoltaic thermal (PVT) double slope active solar still
    Singh, Gajendra
    Kumar, Shiv
    Tiwari, G. N.
    DESALINATION, 2011, 277 (1-3) : 399 - 406
  • [29] Performance evaluation of an inverted absorber solar still integrated with a refrigeration cycle and an inverted absorber solar still
    Abdul-Wahab, Sabah A.
    Al-Hatmi, Yousuf Y.
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2013, 17 (06) : 642 - 648
  • [30] Effect of glass inclination angle on solar still performance
    Azooz, A. A.
    Younis, G. G.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2016, 8 (03)