Use of Attenuated Total Reflectance Mid-Infrared Spectroscopy for Rapid Prediction of Amino Acids in Chinese Rice Wine

被引:14
|
作者
Wu, Zhengzong [1 ,2 ]
Xu, Enbo [1 ,2 ]
Long, Jie [1 ,2 ]
Wang, Fang [1 ,2 ]
Xu, Xueming [1 ]
Jin, Zhengyu [1 ,2 ]
Jiao, Aiquan [1 ,2 ]
机构
[1] Jiangnan Univ, State Key Lab Food Sci & Technol, Sch Food Sci & Technol, Wuxi 214122, Peoples R China
[2] Jiangnan Univ, Synerget Innovat Ctr Food Safety & Nutr, Wuxi 214122, Peoples R China
关键词
amino acids; Chinese rice wine; Fourier transform infrared spectroscopy; genetic algorithms; synergy interval partial least squares; NEAR-INFRARED SPECTROSCOPY; FT-MIR SPECTROSCOPY; MULTIVARIATE CLASSIFICATION; ATR-IR; FERMENTATION; RED; QUANTIFICATION; ALGORITHM; SELECTION; GRAPE;
D O I
10.1111/1750-3841.12961
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The high content of amino acids of Chinese rice wine (CRW), especially essential amino acids makes it a food increasingly demanded by consumers. Rapid detection technique of amino acid content, which is an important quality and function index of CRW, is highly desirable for consumers, producers as well as administrative authorities. In this study, the potential of Fourier transform infrared spectroscopy (FT-IR) as a novel and rapid analytical technique to determine 17 free amino acids in CRW were investigated. Genetic algorithms (GA) and synergy interval partial least squares (SiPLS) were used to select the most efficient spectral variables to improve the prediction precision of the classic partial least squares (PLS) model constructed on the full-spectrum. The results demonstrated that compared with the PLS model using all wavelengths of FT-IR spectra, the prediction precision of model based on the spectral variables selected by GA and SiPLS was significantly improved, especially for arginine and proline. After systemic comparison and discussion, it was found that GA-SiPLS model achieved the best performance, with the correlation coefficient in calibration (R-2 (cal)) higher than 0.80 and the residual predictive deviation higher than 2.00 for all of the free amino acids analyzed in this study. The overall results confirmed that FT-IR combined with efficient variable selection algorithms is a method that may be useful to replace the traditional methods for routine analysis of free amino acids in CRW. Practical Application This research presented a rapid and accurate method to determine the free amino acid contents in Chinese rice wine without sophisticated pretreatment of the samples. The approach reported in this study could be applied to quality control in wineries. It would also be useful to authenticity assurance to prevent illegal adulteration and to guarantee the correct value estimation.
引用
收藏
页码:C1670 / C1679
页数:10
相关论文
共 50 条
  • [21] The mid-infrared (attenuated total reflection) spectroscopy of ethylene carbonate in water
    Brooksby, PA
    Fawcett, WR
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2001, 57 (06) : 1207 - 1221
  • [22] Mid-Infrared Dual-Comb Spectroscopy of Liquid-Phase Samples using Attenuated Total Reflectance
    Herman, D.
    Ycas, G.
    Giorgetta, F. R.
    Waxman, E.
    Baumann, E.
    Coddington, I.
    Newbury, N. R.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [23] Exploration of attenuated total reflectance mid-infrared spectroscopy and multivariate calibration to measure immunoglobulin G in human sera
    Hou, Siyuan
    Riley, Christopher B.
    Mitchell, Cynthia A.
    Shaw, R. Anthony
    Bryanton, Janet
    Bigsby, Kathryn
    McClure, J. Trenton
    TALANTA, 2015, 142 : 110 - 119
  • [24] Quantitative analysis of adulterated pear juice based on attenuated total reflectance mid-infrared spectroscopy and bagging PLS
    Tan, Chao
    Chen, Hui
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 125
  • [25] Measurement of Fructose, Glucose, Maltose and Sucrose in Barley Malt Using Attenuated Total Reflectance Mid-infrared Spectroscopy
    Huang, Yichao
    Carragher, John
    Cozzolino, Daniel
    FOOD ANALYTICAL METHODS, 2016, 9 (04) : 1079 - 1085
  • [26] Soil Nutrient Detection Method Based on Combining Mid-Infrared Attenuated Total Reflection and Diffuse Reflectance Spectroscopy
    Chen Chen
    Li Zhi-wei
    Dong Da-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (11) : 3557 - 3561
  • [27] Measurement of Fructose, Glucose, Maltose and Sucrose in Barley Malt Using Attenuated Total Reflectance Mid-infrared Spectroscopy
    Yichao Huang
    John Carragher
    Daniel Cozzolino
    Food Analytical Methods, 2016, 9 : 1079 - 1085
  • [28] A Multivariate Approach Using Attenuated Total Reflectance Mid-infrared Spectroscopy To Measure the Surface Mannoproteins and β-Glucans of Yeast Cell Walls during Wine Fermentations
    Moore, John P.
    Zhang, Song-Lei
    Nieuwoudt, Helene
    Divol, Benoit
    Trygg, Johan
    Bauer, Florian F.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (45) : 10054 - 10063
  • [29] Development of a rapid "fingerprinting" system for wine authenticity by mid-infrared spectroscopy
    Bevin, Christopher J.
    Fergusson, Allison J.
    Perry, Wade B.
    Janik, Leslie J.
    Cozzolino, Daniel
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (26) : 9713 - 9718
  • [30] Mid-infrared reflectance spectroscopy as a tool for forage feed composition prediction
    Cleland, Josiah D.
    Johnson, Ellie
    Morel, Patrick C. H.
    Kenyon, Paul R.
    Waterland, Mark R.
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 2018, 241 : 102 - 111