Observation of cardiogenic flow oscillations in healthy subjects with hyperpolarized 3He MRI

被引:11
|
作者
Collier, Guilhem J. [1 ]
Marshall, Helen [1 ]
Rao, Madhwesha [1 ]
Stewart, Neil J. [1 ]
Capener, David [1 ]
Wild, Jim M. [1 ]
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Acad Unit Radiol, Sheffield S10 2JF, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
cardiogenic oscillations; MRI; hyperpolarized gases; flow; lungs; GAS-FLOW; HUMAN LUNG; AIR-FLOW; AIRWAYS; DEPOSITION; DISPERSION; GRAVITY; ASYMMETRY; PARTICLES; DEEP;
D O I
10.1152/japplphysiol.01068.2014
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Recently, dynamic MRI of hyperpolarized He-3 during inhalation revealed an alternation of the image intensity between left and right lungs with a cardiac origin (Sun Y, Butler JP, Ferrigno M, Albert MS, Loring SH. Respir Physiol Neurobiol 185: 468-471, 2013). This effect is investigated further using dynamic and phase-contrast flow MRI with inhaled 3He during slow inhalations (flow rate similar to 100 ml/s) to elucidate airflow dynamics in the main lobes in six healthy subjects. The ventilation MR signal and gas inflow in the left lower lobe (LLL) of the lungs were found to oscillate clearly at the cardiac frequency in all subjects, whereas the MR signals in the other parts of the lungs had a similar oscillatory behavior but were smaller in magnitude and in anti-phase to the signal in the left lower lung. The airflow in the main bronchi showed periodic oscillations at the frequency of the cardiac cycle. In four of the subjects, backflows were observed for a short period of time of the cardiac cycle, demonstrating a pendelluft effect at the carina bifurcation between the left and right lungs. Additional H-1 structural MR images of the lung volume and synchronized ECG recording revealed that maximum inspiratory flow rates in the LLL of the lungs occurred during systole when the corresponding left lung volume increased, whereas the opposite effect was observed during diastole, with gas flow redirected to the other parts of the lung. In conclusion, cardiogenic flow oscillations have a significant effect on regional gas flow and distribution within the lungs.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 50 条
  • [31] Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI
    Fischer, MC
    Kadlecek, S
    Yu, JS
    Ishii, M
    Emami, K
    Vahdat, V
    Lipson, DA
    Rizi, RR
    ACADEMIC RADIOLOGY, 2005, 12 (11) : 1430 - 1439
  • [32] Hyperpolarized 3he Mri Ventilation Defects In Healthy Elderly Never-Smokers: Response To Deep Inspiration And Salbutamol
    Sheikh, K.
    Svenningsen, S.
    Kirby, M.
    McCormack, D. G.
    Parraga, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [33] Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema
    Diaz, Sandra
    Casselbrant, Ingrid
    Piitulainen, Eeva
    Pettersson, Goran
    Magnusson, Peter
    Peterson, Barry
    Wollmer, Per
    Leander, Peter
    Ekberg, Olle
    Akeson, Per
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 763 - 770
  • [34] Diffusion imaging with hyperpolarized 3He gas
    Schmidt, DM
    George, JS
    Penttila, SI
    Caprihan, A
    Fukushima, E
    JOURNAL OF MAGNETIC RESONANCE, 1997, 129 (02) : 184 - 187
  • [35] MR imaging with hyperpolarized 3He gas
    Physics Department, Princeton University, P.O. Box 708, Princeton, NJ 08544-0708, United States
    MAGN. RESON. MED., 2 (271-275):
  • [36] MR elastography of the lung with hyperpolarized 3He
    McGee, Kiaran P.
    Hubmayr, Rolf D.
    Ehman, R. L.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 14 - 18
  • [37] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    C.P. Bidinosti
    J. Choukeife
    G. Tastevin
    P.-J. Nacher
    A. Vignaud
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 255 - 258
  • [38] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    Bidinosti, CP
    Choukeife, J
    Tastevin, G
    Vignaud, A
    Nacher, PJ
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) : 255 - 258
  • [39] In Vivo Lung Morphometry with Accelerated Hyperpolarized 3He Diffusion MRI: A Preliminary Study
    Chang, Yulin V.
    Quirk, James D.
    Yablonskiy, Dmitriy A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1609 - 1614
  • [40] High-speed dynamic MRI of lung ventilation with hyperpolarized 3He and EPI
    Yablonskiy, DA
    Gierada, DS
    Saam, BT
    Conradi, MS
    RADIOLOGY, 1998, 209P : 449 - 450