Research and Design on Walking Device for 500kV Transmission Line 4-bundle Conductors

被引:0
|
作者
Yu, Xiangyong [1 ]
Liu, Zhilin [1 ]
机构
[1] State Grid Anhui Elect Power Co Maintenance Co, Luan, Anhui, Peoples R China
关键词
inspection; walking device; climbing obstacle; four bundled conductors;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For the labor-intensive, low work efficiency, greater risk and other issues of human traces for 500kV transmission line inspection, a new walking device for 500kV transmission line four bundled conductors was proposed. This walking device adopted battery as a power source, was suitable for large span transmission lines, which can automatically span spacers, linear hanging string and shockproof hammer. Described the design and function of walking devices in detail, and finally introduced the field trial. The test results showed that the walking device could achieve wire walking requirements and design standards.
引用
收藏
页码:232 / 235
页数:4
相关论文
共 50 条
  • [41] BPA 500-KV TRANSMISSION-LINE AND SUBSTATION DESIGN
    STEVENS, RF
    DAVIES, IT
    MARJERRISON, MN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 687 - +
  • [42] INSULATION PERFORMANCE ANALYSIS OF A 500-KV TRANSMISSION LINE DESIGN
    ANNESTRAND, S
    BOSSUYT, EF
    REPPEN, ND
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (03): : 429 - +
  • [43] Research on DC Ice-melting Technologies for 500kV AC Transmission Lines
    Hao, Weiwei
    Peng, Shurong
    Lu, Jiazheng
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1663 - 1666
  • [44] Research on Eliminating Closing Resistors in 500kV and above Transmission lines circuit Breakers
    Tian Shu
    Guo Peng-jun
    He Jin-peng
    ELECTRICAL INFORMATION AND MECHATRONICS AND APPLICATIONS, PTS 1 AND 2, 2012, 143-144 : 3 - 7
  • [45] Engineering analysis of electrical effects for the COTP 500kV transmission line and EBMUD aqueduct corridor
    Lewis, OC
    Bell, GK
    Ma, JX
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 499 - 507
  • [46] Research on the influence of 500kV Power Engineering Materials line Parameters to EFT/B
    Du, Yinjing
    Kang, Wei
    Jun, Liu
    Zhang, Lixia
    ADVANCED RESEARCH ON MATERIAL ENGINEERING, CHEMISTRY, BIOINFORMATICS III, 2014, 830 : 76 - +
  • [47] Study of Switching Overvoltage for Metallic Return Line of ±500kV Flexible HVDC Transmission Project
    Li, Xiaolan
    Zhou, Peihong
    Cao, Zhaojun
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 113 - 120
  • [48] Shielding Failure Risk Assessment for 500kV Typical Transmission Line in Anhui Power Grid
    Zhao, Chun
    Zhen, Shiling
    Xie, Yaoheng
    Gu, Shanqiang
    Ding, Li
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 725 - +
  • [49] 500kV Transmission Line Lightning Transformation Evaluation Based on Improved Analytic Hierarchy Process
    Duan, R. C.
    Wang, F. H.
    Liu, Y. D.
    Huang, R. H.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [50] Evaluation of Auto-reclose Performance of 500kV Transmission Line with Shunt Reactor in Indonesia
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung Sofiarto
    Tambunan, Handrea Bernando
    PROCEEDINGS OF 2018 THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE), 2018, : 320 - 324