Potentiometric urea biosensor utilizing nanobiocomposite of chitosan-iron oxide magnetic nanoparticles

被引:38
|
作者
Ali, A. [2 ,3 ]
AlSalhi, M. S. [1 ,4 ]
Atif, M. [1 ,4 ,7 ]
Ansari, Anees A. [5 ]
Israr, M. Q. [2 ]
Sadaf, J. R. [2 ]
Ahmed, E. [3 ]
Nur, O. [2 ]
Willander, M. [2 ,6 ]
机构
[1] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
[2] Linkoping Univ, Dept Sci & Technol, SE-60174 Norrkoping, Sweden
[3] Bahauddin Zakriya Univ, Dept Phys, Multan, Pakistan
[4] King Saud Univ, Res Chair Laser Diag Canc, Riyadh, Saudi Arabia
[5] King Saud Univ, King Abdullah Inst Nanotechnol, Riyadh 11451, Saudi Arabia
[6] King Saud Univ, Coll Sci, Riyadh, Saudi Arabia
[7] Natl Inst Laser & Optron, Islamabad, Pakistan
关键词
iron oxide (Fe3O4) magnetic nanoparticles; emission characteristics; potentiometric response; urea biosensor; chitosan solution; DIRECT ELECTRON-TRANSFER; FE3O4; NANOPARTICLES; COMPOSITE FILM; IMMUNOSENSOR; HEMOGLOBIN;
D O I
10.1088/1742-6596/414/1/012024
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The iron oxide (Fe3O4) magnetic nanoparticles have been fabricated through a simple, cheap and reproducible approach. Scanning electron microscope, x-rays powder diffraction of the fabricated nanoparticles. Furthermore, the fabrication of potentiometric urea biosensor is carried out through drop casting the initially prepared isopropanol and chitosan solution, containing Fe3O4 nanoparticles, on the glass fiber filter with a diameter of 2 cm and a copper wire (of thickness similar to 500 mu m) has been utilized to extract the voltage signal from the functionalized nanoparticles. The functionalization of surface of the Fe3O4 nanoparticles is obtained by the electrostatically immobilization of urease onto the nanobiocomposite of the chitosan-Fe3O4 in order to enhance the sensitivity, specificity, stability and reusability of urea biosensor. Electrochemical detection procedure has been adopted to measure the potentiometric response over the wide logarithmic concentration range of the 0.1 mM to 80 mM. The Fe3O4 nanoparticles based urea biosensor depicts good sensitivity with similar to 42 mV per decade at room temperature. Durability of the biosensor could be considerably enhanced by applying a thin layer of the nafion. In addition, the reasonably stable output response of the biosensor has been found to be around 12 sec.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Chitosan-iron oxide nanobiocomposite based immunosensor for ochratoxin-A
    Kaushik, Ajeet
    Solanki, Pratima R.
    Ansari, Anees A.
    Ahmad, Sharif
    Malhotra, Bansi D.
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) : 1364 - 1368
  • [2] Thermal and magnetic properties of chitosan-iron oxide nanoparticles
    Soares, Paula I. P.
    Machado, Diana
    Laia, Cesar
    Pereira, Laura C. J.
    Coutinho, Joana T.
    Ferreira, Isabel M. M.
    Novo, Carlos M. M.
    Borges, Joao Paulo
    CARBOHYDRATE POLYMERS, 2016, 149 : 382 - 390
  • [3] Iron oxide-chitosan nanobiocomposite for urea sensor
    Kaushik, Ajeet
    Solanki, Pratima R.
    Ansari, Anees A.
    Sumana, G.
    Ahmad, Sharif
    Malhotra, Bansi D.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02): : 572 - 580
  • [4] Silver-chitosan nanobiocomposite as urea biosensor
    Ali, Akbar
    Fakhar-E-Alam, Muhammad
    Abbas, Najeeb
    Wazir, Zafar
    Willander, Magnus
    Tufail, Muhammad
    Atif, M.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2014, 8 (11-12): : 1238 - 1242
  • [5] Potentiometric urea biosensor based on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles
    Cevik, Emre
    Senel, Mehmet
    Baykal, Abdulhadi
    CURRENT APPLIED PHYSICS, 2013, 13 (01) : 280 - 286
  • [6] Cobalt oxide magnetic nanoparticles–chitosan nanocomposite based electrochemical urea biosensor
    A. Ali
    M. Israr-Qadir
    Z. Wazir
    M. Tufail
    Z. H. Ibupoto
    S. Jamil-Rana
    M. Atif
    S. A. Khan
    M. Willander
    Indian Journal of Physics, 2015, 89 : 331 - 336
  • [7] Cobalt oxide magnetic nanoparticles-chitosan nanocomposite based electrochemical urea biosensor
    Ali, A.
    Israr-Qadir, M.
    Wazir, Z.
    Tufail, M.
    Ibupoto, Z. H.
    Jamil-Rana, S.
    Atif, M.
    Khan, S. A.
    Willander, M.
    INDIAN JOURNAL OF PHYSICS, 2015, 89 (04) : 331 - 336
  • [8] THE POTENTIOMETRIC UREA BIOSENSOR USING CHITOSAN MEMBRANE
    Mulyasuryani, Ani
    Roosdiana, Anna
    Srihardyastutie, Arie
    INDONESIAN JOURNAL OF CHEMISTRY, 2010, 10 (02) : 162 - 166
  • [9] Zinc oxide-chitosan nanobiocomposite for urea sensor
    Solanki, Pratima R.
    Kaushik, Ajeet
    Ansari, Anees A.
    Sumana, G.
    Malhotra, B. D.
    APPLIED PHYSICS LETTERS, 2008, 93 (16)
  • [10] An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode
    Chauhan, Nidhi
    Narang, Jagriti
    Pundir, Meena C. S.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2012, 51 (05) : 879 - 886