An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode

被引:31
|
作者
Chauhan, Nidhi [1 ]
Narang, Jagriti [1 ]
Pundir, Meena C. S. [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biochem, Rohtak 124001, Haryana, India
关键词
Glutathione; Glutathione oxidase; Gold coated magnetic nanoparticles; Chitosan; Amperometric biosensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL DETECTION; REDUCED GLUTATHIONE; CARBON NANOTUBES; DISULFIDE LEVELS; IMMOBILIZATION; NANOCOMPOSITE; MATRIX; FABRICATION; SAMPLES;
D O I
10.1016/j.ijbiomac.2012.08.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for development of an amperometric biosensor for determination of glutathione (GSH), by immobilizing covalently a glutathione oxidase (GSHOx) onto the surface of gold coated magnetic nanoparticles (Fe@AuNPs) modified Pt electrode. Chitosan was used to introduce amino groups onto the surface of Fe@AuNPs. The morphology and covalent linkage of GSHOx led to high enzyme loading and better shelf life. The enzyme electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), Fourier transform infrared (FTIR) and electrochemical impedance spectroscopy (EIS). The electrode showed maximum response within 4s, when polarized at +0.4 V, pH 7.0 and 25 degrees C. There was a linear relationship between electrode response and glutathione concentrations in the range 5.0-4000 mu mol L-1 with a detection limit of 0.1 mu mol L-1. An amperometric method of GSH determination was developed using this biosensor. The evaluation studies showed that the method was reliable as mean analytic recoveries of 50 mu M and 100 mu M of GSH were 97.5 +/- 1.7 and 96.1 +/- 1.3 respectively and within and between CVs for glutathione determination in blood RBCs were <2.14% and <2.39% respectively. The biosensor showed 50% loss in its initial activity after its 150 uses over a period 4 months, when stored at 4 degrees C. GSH concentration in hemolysated erythrocytes as measured by the present biosensor was 2.8 mmol L-1 in apparently healthy persons. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:879 / 886
页数:8
相关论文
共 50 条
  • [1] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rachna Rawal
    Sheetal Chawla
    Tulika Dahiya
    Chandra Shekhar Pundir
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2599 - 2608
  • [2] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Dahiya, Tulika
    Pundir, Chandra Shekhar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2599 - 2608
  • [3] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 838 - 844
  • [4] An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 144 - 150
  • [5] Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode
    Chauhan, Nidhi
    Pundir, C. S.
    BIOSENSORS & BIOELECTRONICS, 2014, 61 : 1 - 8
  • [6] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    Microchimica Acta, 2012, 176 : 279 - 285
  • [7] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [8] Amperometric glucose biosensor based on gold nanorods and chitosan comodified Au electrode
    Li Yingying
    Wang Xiaoxia
    Dong Xiang
    He Zhipeng
    Zhang Haiqian
    RARE METALS, 2010, 29 (03) : 238 - 242
  • [9] Amperometric glucose biosensor based on gold nanorods and chitosan comodified Au electrode
    LI Yingyinga
    RareMetals, 2010, 29 (03) : 238 - 242
  • [10] Amperometric glucose biosensor based on gold nanorods and chitosan comodified Au electrode
    Yingying Li
    Xiaoxia Wang
    Xiang Dong
    Zhipeng He
    Haiqian Zhang
    Rare Metals, 2010, 29 : 238 - 242