Agreement and Reproducibility of Apparent Diffusion Coefficient Measurements of Dual-b-Value and Multi-b-Value Diffusion-Weighted Magnetic Resonance Imaging at 1.5 Tesla in Phantom and in Soft Tissues of the Abdomen

被引:38
|
作者
Corona-Villalobos, Celia Pamela [1 ]
Pan, Li [1 ,2 ]
Halappa, Vivek Gowdra [1 ]
Bonekamp, Susanne [1 ]
Lorenz, Christine H. [1 ,2 ]
Eng, John [1 ]
Kamel, Ihab R. [1 ]
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Siemens Corp Res, Ctr Appl Med Imaging, Baltimore, MD USA
关键词
diffusion-weighted imaging; apparent diffusion coefficient; phantom; abdominal imaging; TREATMENT RESPONSE; BREATH-HOLD; MRI; CANCER; LIVER; ONCOLOGY; THERAPY; LESIONS; CELLULARITY; CARCINOMA;
D O I
10.1097/RCT.0b013e3182720e07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the coefficient of variation (CV) and long-term reproducibility of apparent diffusion coefficient (ADC) in a simple fluid-filled phantom and abdominal organs simultaneously. Materials and Methods: Retrospective institutional review board-approved and Health Insurance Portability and Accountability Act-compliant study sequentially selected 100 patients who underwent clinically indicated abdominal magnetic resonance imaging. A subset of 58 patients had repeat scans within 2 to 5 months after the initial magnetic resonance imaging. Two diffusion-weighted imaging techniques (b-values 0Y750 mm(2)/s) were performed to compare the ADC values. Mean ADC values were calculated for 10 locations and the reference phantom. The CV and Bland-Altman plots were calculated for the phantom and soft tissues at each session and location. Results: There were no significant differences in the mean ADC values between repeated acquisitions. However, ADC values were statistically higher using dual-b-value than multi-b-value diffusion-weighted imaging. The CV for the phantom was 8.6 versus 10.8 for dual-b-value and multi-b-value, respectively. The CVs for the soft tissues had a wider range compared with that of the phantom (liver, 12.6 vs 9.0; spleen, 11.7 vs 11.2; gallbladder, 11.0 vs 13.6; head of pancreas, 14.6 vs 14.7; body of pancreas, 13.4 vs 13.0; tail of pancreas, 14.8 vs 16.3; right kidney, 9.1 vs 9.6; left kidney, 9.3 vs 9.3; right paraspinal muscle, 7.9 vs 7.5; left paraspinal muscle, 7.3 vs 7.3, respectively). Conclusions: A change in ADC less than 11% falls into the range of measurement variability. Paraspinal muscle could potentially be used as an internal reference parameter.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [31] Variability of radiomic features extracted from multi-b-value diffusion-weighted images in hepatocellular carcinoma
    Zhang, Jing
    Qiu, Qingtao
    Duan, Jinghao
    Gong, Guanzhong
    Jiang, Qingjun
    Sun, Gang
    Yin, Yong
    TRANSLATIONAL CANCER RESEARCH, 2019, 8 (01) : 130 - 140
  • [32] Differential Diagnosis of Benign and Malignant Breast Tumors Using Apparent Diffusion Coefficient Value Measured Through Diffusion-Weighted Magnetic Resonance Imaging
    Qu, Rong-Feng
    Guo, Dong-Rui
    Chang, Zhe-Xing
    Meng, Jie
    Sun, Yan
    Hao, Shu-Hong
    Shi, Guang
    Sun, Jian
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 513 - 522
  • [33] Magnetic Resonance Imaging of Peritoneal Carcinomatosis: Evaluation of High b-Value Computed Diffusion-Weighted Imaging
    Ablefoni, Maxime
    Leonhardi, Jakob
    Ehrengut, Constantin
    Mehdorn, Matthias
    Sucher, Robert
    Gockel, Ines
    Denecke, Timm
    Meyer, Hans-Jonas
    CURRENT ONCOLOGY, 2022, 29 (07) : 4593 - 4603
  • [34] Diagnostic Efficiency of Multi-b-Value Intravoxel Incoherent Motion Diffusion Weighted Imaging for Pulmonary Masses
    Zeng, Chun-Guang
    Zong, Deng-Wei
    Guo, Chen-Yang
    Li, Hai-Liang
    Cheng, Hong-Tao
    Liu, Jian
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (08) : 1677 - 1681
  • [35] The diagnostic value of diffusion-weighted magnetic resonance imaging in characterization of musculoskeletal soft tissue tumors
    Romeih, Marwa
    Raafat, Tarek
    Khalaf, Mohamed
    Sallam, Kareem
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (02): : 400 - 407
  • [36] A Modified Tri-Exponential Model for Multi-b-value Diffusion-Weighted Imaging: A Method to Detect the Strictly Diffusion-Limited Compartment in Brain
    Zeng, Qiang
    Shi, Feina
    Zhang, Jianmin
    Ling, Chenhan
    Dong, Fei
    Jiang, Biao
    FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [37] Diffusion-weighted magnetic resonance imaging: the influence of different b-gradient factors on the apparent diffusion coefficient for normal fibroglandular tissue of the breast
    Dorrius, M.
    Kappert, P.
    Sijens, P. E.
    Jansen-van der Weide, M. C.
    Oudkerk, M.
    EJC SUPPLEMENTS, 2008, 6 (07): : 64 - 64
  • [38] Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint
    Tang, Xin
    Gao, Juan
    Aburas, Ahmed
    Wu, Dan
    Chen, Zhuo
    Chen, Hao
    Hu, Chenxi
    MAGNETIC RESONANCE IMAGING, 2024, 110 : 138 - 148
  • [39] Potential of diffusion-weighted imaging in magnetic resonance enterography to identify neoplasms in the ileocecal region: Use of ultra-high b-value diffusion-weighted imaging
    Yu, Hao
    Feng, Cui
    Wang, Zi
    Li, Jianjun
    Wang, Yanchun
    Hu, Xuemei
    Li, Zhen
    Shen, Yaqi
    Hu, Daoyu
    ONCOLOGY LETTERS, 2019, 18 (02) : 1451 - 1457
  • [40] Diffusion-Weighted Magnetic Resonance Imaging for Characterization of Focal Liver Masses: Impact of Parallel Imaging (SENSE) and b Value
    Erturk, Sukru Mehmet
    Ichikawa, Tomoaki
    Sano, Katsuhiro
    Motosugi, Utarou
    Sou, Hironobu
    Araki, Tsutomu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (06) : 865 - 871