A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy

被引:32
|
作者
Kim, Jinkoo [1 ]
Kumar, Sanath [1 ]
Liu, Chang [1 ]
Zhong, Hualiang [1 ]
Pradhan, Deepak [1 ]
Shah, Mira [1 ]
Cattaneo, Richard [1 ]
Yechieli, Raphael [1 ]
Robbins, Jared R. [1 ]
Elshaikh, Mohamed A. [1 ]
Chetty, Indrin J. [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 22期
关键词
LOCALIZATION; ACCURACY; TIME; TARGET; ONLINE; CT;
D O I
10.1088/0031-9155/58/22/8077
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deformable image registration (DIR) is an integral component for adaptive radiation therapy. However, accurate registration between daily cone-beam computed tomography (CBCT) and treatment planning CT is challenging, due to significant daily variations in rectal and bladder fillings as well as the increased noise levels in CBCT images. Another significant challenge is the lack of 'ground-truth' registrations in the clinical setting, which is necessary for quantitative evaluation of various registration algorithms. The aim of this study is to establish benchmark registrations of clinical patient data. Three pairs of CT/CBCT datasets were chosen for this institutional review board approved retrospective study. On each image, in order to reduce the contouring uncertainty, ten independent sets of organs were manually delineated by five physicians. The mean contour set for each image was derived from the ten contours. A set of distinctive points (round natural calcifications and three implanted prostate fiducial markers) were also manually identified. The mean contours and point features were then incorporated as constraints into a B-spline based DIR algorithm. Further, a rigidity penalty was imposed on the femurs and pelvic bones to preserve their rigidity. A piecewise-rigid registration approach was adapted to account for the differences in femur pose and the sliding motion between bones. For each registration, the magnitude of the spatial Jacobian (|JAC|) was calculated to quantify the tissue compression and expansion. Deformation grids and finite-element-model-based unbalanced energy maps were also reviewed visually to evaluate the physical soundness of the resultant deformations. Organ DICE indices (indicating the degree of overlap between registered organs) and residual misalignments of the fiducial landmarks were quantified. Manual organ delineation on CBCT images varied significantly among physicians with overall mean DICE index of only 0.7 among redundant contours. Seminal vesicle contours were found to have the lowest correlation amongst physicians (DICE = 0.5). After DIR, the organ surfaces between CBCT and planning CT were in good alignment with mean DICE indices of 0.9 for prostate, rectum, and bladder, and 0.8 for seminal vesicles. The Jacobian magnitudes |JAC| in the prostate, rectum, and seminal vesicles were in the range of 0.4-1.5, indicating mild compression/expansion. The bladder volume differences were larger between CBCT and CT images with mean |JAC| values of 2.2, 0.7, and 1.0 for three respective patients. Bone deformation was negligible (|JAC| = similar to 1.0). The difference between corresponding landmark points between CBCT and CT was less than 1.0 mm after DIR. We have presented a novel method of establishing benchmark DIR accuracy between CT and CBCT images in the pelvic region. The method incorporates manually delineated organ surfaces and landmark points as well as pixel similarity in the optimization, while ensuring bone rigidity and avoiding excessive deformation in soft tissue organs. Redundant contouring is necessary to reduce the overall registration uncertainty.
引用
收藏
页码:8077 / 8097
页数:21
相关论文
共 50 条
  • [31] IMAGE-GUIDED RADIOTHERAPY (IGRT) BY CONE-BEAM CT (CBCT) IN PROSTATE CANCER PATIENTS: DAILY OR WEEKLY VERIFICATION?
    Ferrer Gonzalez, F.
    Ballivy, O.
    Sancho, I.
    Boladeras Inglada, A. M.
    Leon, P. R.
    Gutierrez, C.
    Martinez, E.
    Gonzalez Imhoff, M. N.
    Prat, X.
    Pera, J.
    Guedea, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S404 - S405
  • [32] An Investigation of Gradient-Based Deformable Registration of CT and CBCT Image
    Ma, C.
    Yin, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E632 - E632
  • [33] Evaluation of Nine Similarity Metrics for Intensity-Based CT-To-CBCT Prostate Registrations
    Kim, J.
    Hammoud, R.
    Chetty, I.
    Pradhan, D.
    Movsas, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] IMAGE IMPROVEMENT OF 4D CT USING DEFORMABLE REGISTRATIONS OF THE RESPIRATION PHASES
    Brink, C.
    Nielsen, T. B.
    Persson, G.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S440 - S440
  • [35] Assessment of the use of synthetic CT produced by deformable image registration of planning CT and CBCT in adaptive radiotherapy treatments of head and neck cancers
    Sanju
    Mukherji, Ashutosh
    Nanda, Sambit S.
    Dokania, Shubham
    Kataria, Alka
    Kumar, Narender
    Saini, Vinay
    Barman, Sanjay
    Epili, Dandpani R.
    Choubey, Ajay
    Patil, Ninad H.
    Krishnan, Ajay
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 131
  • [36] Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images
    Alshammari, Shorug S.
    Yaddanapudi, Sridhar
    Ivancic, Rok
    Anderle, Kristjan
    Li, Jonathan G.
    Furutani, Keith M.
    Beltran, Chris J.
    Lu, Bo
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 32
  • [37] Deformable Image Registration in the Radiotherapy of Breast Cancer
    Duma, M. N.
    Pargmann, L.
    Volkel-Beltran, S.
    Boehm, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S101 - S101
  • [38] Deformable image registration for breast cancer radiotherapy
    Duma, M. N.
    Pargmann, L.
    Boehm, M.
    Wittig, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1043 - S1044
  • [39] Evaluation of the geometric and dosimetric accuracies of deformable image registration of targets and critical organs in prostate CBCT-guided adaptive radiotherapy
    Jassim, Hussam Hameed
    Nedaie, Hassan Ali
    Banaee, Nooshin
    Geraily, Ghazale
    Kazemian, Ali
    Makrani, Danial Seifi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (11):
  • [40] Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning
    Hamdan, Iyas
    Bert, Julien
    Le Rest, Catherine Cheze
    Tasu, Jean Pierre
    Boussion, Nicolas
    Valeri, Antoine
    Dardenne, Guillaume
    Visvikis, Dimitris
    MEDICAL PHYSICS, 2017, 44 (12) : 6447 - 6455