The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques

被引:35
|
作者
Lenz, Mark [1 ]
Windolf, Markus [1 ]
Mueckley, Thomas [2 ]
Hofmann, Gunther O. [2 ]
Wagner, Michael [3 ]
Richards, Robert G. [1 ]
Schwieger, Karsten [1 ]
Gueorguiev, Boyko [1 ]
机构
[1] AO Res Inst Davos, CH-7270 Davos, Switzerland
[2] Univ Jena, Dept Traumatol Hand & Reconstruct Surg, D-07740 Jena, Germany
[3] Wilhelminenspital Stadt Wien, Dept Traumatol, A-1160 Vienna, Austria
关键词
FEMORAL-SHAFT FRACTURES; TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; TIP; STABILIZATION; REPLACEMENT; IMPLANT; STEM;
D O I
10.1007/s00264-012-1574-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mechanical properties of a locking attachment plate construct (LAP-LCP), allowing bicortical screw placement laterally to the prosthesis stem, are compared to a cerclage-LCP construct. Eight right synthetic femora with implanted uncemented hip endoprosthesis were cut distally and fixed with LCP, monocortical locking screws and either LAP (n = 4) or cerclage (n = 4). Cyclic testing was performed with monotonically increasing sinusoidal load until failure. Relative movements at the plate-femur interface were registered by motion tracking. Statistical differences were detected by unpaired t-test and general linear model repeated measures. Stiffness of the LAP-LCP was significantly higher at the beginning (875.4 N/mm +/- 29.8) and after 5000 cycles (1213.0 N/mm +/- 101.1) compared to the cerclage-LCP (644.96 N/mm +/- 50.1 and 851.9 N/mm +/- 81.9), with p = 0.013. Relative movements for AP-bending (B) and axial translation (T) of the LAP-LCP at the beginning (0.07A degrees A +/- 0.02, 0.20 mm +/- 0.08), after 500 cycles (0.16A degrees A +/- 0.10, 0.26 mm +/- 0.07) and after 5000 cycles (0.26A degrees A +/- 0.11, 0.31 mm +/- 0.07) differed significantly from the cerclage-LCP (beg.: 0.26A degrees A +/- 0.04, 0.28 mm +/- 0.05; 500 cyc: 0.47A degrees A +/- 0.03, 0.53 mm +/- 0.07; 5000 cyc.: 0.63A degrees A +/- 0.18, 0.79 mm +/- 0.13), with B: p = 0.02, T: p = 0.04. Relative movements for medial bending were not significantly different between the two constructs. Cycles to failure (criterion 1 mm axial translation) differed significantly between LAP-LCP (19,519 +/- 1,758) and cerclage-LCP (11,265 +/- 2,472), with p = 0.035. Biomechanically, the LAP-LCP construct improves proximal fixation of periprosthetic fractures compared to the cerclage-LCP construct.
引用
收藏
页码:1915 / 1921
页数:7
相关论文
共 50 条
  • [41] Osteosynthesis Of Proximal Periprosthetic Femur Fractures With A Polyaxial Locking Plate System: Results Of A Prospective Multicenter Study
    Kesterke, Nicolas
    Nuber, Monika
    Vaquero, Javier
    Chana, Francisco
    Mayr, Edgar
    Erhardt, Johannes
    SWISS MEDICAL WEEKLY, 2014, 144 : 43S - 43S
  • [42] Comparison of different fixation techniques for periprosthetic fractures: a biomechanical study of a new implant
    Mehmet Nuri Konya
    Ugur Yuzuguldu
    Recep Altin
    Ugur Fidan
    International Orthopaedics, 2021, 45 : 1817 - 1826
  • [43] Comparison of different fixation techniques for periprosthetic fractures: a biomechanical study of a new implant
    Konya, Mehmet Nuri
    Yuzuguldu, Ugur
    Altin, Recep
    Fidan, Ugur
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1817 - 1826
  • [44] BASICERVICAL FRACTURES OF THE PROXIMAL FEMUR - A BIOMECHANICAL STUDY OF 3 INTERNAL-FIXATION TECHNIQUES
    BLAIR, B
    KOVAL, KJ
    KUMMER, F
    ZUCKERMAN, JD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (306) : 256 - 263
  • [45] A biomechanical comparison of multidirectional nail and locking plate fixation in unstable olecranon fractures
    Argintar, Evan
    Martin, Benjamin D.
    Singer, Andrea
    Hsieh, Adam H.
    Edwards, Scott
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (10) : 1398 - 1405
  • [46] Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fractures
    Min Bom Kim
    Jae-Woo Cho
    Young Ho Lee
    Won-Yong Shon
    Jung Wee Park
    Jinil Kim
    Jong-Keon Oh
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1193 - 1200
  • [47] Commentary: Locking plate fixation with and without inferomedial screws for proximal humeral fractures: a biomechanical study
    Leung, Frankie
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (02) : 140 - 140
  • [48] Biomechanical Evaluation of Locking Plate Fixation of Proximal Humeral Fractures Augmented With Calcium Phosphate Cement
    Gradl, Gertraud
    Knobe, Matthias
    Stoffel, Marcus
    Prescher, Andreas
    Dirrichs, Timm
    Pape, Hans-Christoph
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (07) : 399 - 404
  • [49] Principles of Locking Plate Fixation of Proximal Humerus Fractures
    Omid, Reza
    Trasolini, Nicholas A.
    Stone, Michael A.
    Namdari, Surena
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (11) : E523 - E535
  • [50] Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fractures
    Kim, Min Bom
    Cho, Jae-Woo
    Lee, Young Ho
    Shon, Won-Yong
    Park, Jung Wee
    Kim, Jinil
    Oh, Jong-Keon
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (09) : 1193 - 1200