Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study

被引:13
|
作者
Ikeda, Kazuhiko [1 ,6 ]
Minakawa, Keiji [1 ]
Muroi, Kazuo [2 ,6 ]
Fujiwara, Shin-ichiro [3 ]
Yamada-Fujiwara, Minami [4 ]
Fujimori, Yoshihiro [5 ,6 ]
Tanosaki, Ryuji [6 ]
Ohto, Hitoshi [1 ,6 ]
机构
[1] Fukushima Med Univ, Dept Blood Transfus & Transplantat Immunol, 1 Hikariga Oka, Fukushima, Fukushima 9601295, Japan
[2] Jichi Med Univ Hosp, Div Cell Transplantat & Transfus, Dept Med, Shimotsuke, Tochigi, Japan
[3] Jichi Med Univ Hosp, Div Hematol, Dept Med, Shimotsuke, Tochigi, Japan
[4] Tohoku Univ Hosp, Div Blood Transfus & Cell Therapy, Sendai, Miyagi, Japan
[5] Hyogo Coll Med, Dept Transfus Med & Cellular Therapy, Nishinomiya, Hyogo, Japan
[6] Japan Soc Transfus Med & Cell Therapy, Cell Therapy Comm, Tokyo, Japan
关键词
PROGENITOR CELLS; HEMATOPOIETIC STEM; SEPARATORS; FLOW; TRANSPLANTATION; PROGRAMS; SPECTRA; SYSTEMS; COUNTS;
D O I
10.1111/trf.13777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Improving apheresis technology may lead to an efficient and safe peripheral blood stem cell (PBSC) collection. Recently, the Spectra Optia (Optia, Terumo BCT) was introduced as an automated apheresis instrument, but comparisons with other instruments have been few. This is the first randomized multicenter and crossover comparison of the Optia with the automated program of the established apheresis instrument, the Spectra (Spectra-Auto, Terumo BCT). STUDY DESIGN AND METHODS: A total of 233 apheresis procedures performed in 46 autologous patients and 108 allogeneic donors were investigated. Apheresis performed in the first day for all subjects using the Spectra-Auto (n = 79) and the Optia (n = 75) were evaluated as first-day analysis. Seventy-nine subjects, who required another session on the second day, underwent apheresis using the other instrument than the first-day instrument and were compared with each other in a paired crossover analysis. RESULTS: The two instruments processed similar volumes with comparable run times and volumes of acid-citrate-dextrose used. The volumes of collected products were greater in the Optia. Yields of mononuclear cells and CD34+ cells were not different, but collection efficiencies were higher in the Optia (p = 0.008 in CE1 of crossover analysis). Spectra-Auto-collected products contained more contaminating red blood cells (RBCs), whereas there was a trend of more contaminating platelets (PLTs) in the Optia-collected products. Slight reductions were noted in the RBC or PLT counts of subjects who underwent apheresis with the Spectra-Auto or the Optia, respectively. CONCLUSION: The Optia is safe and more efficient in the PBSC collection compared with the Spectra-Auto.
引用
收藏
页码:2839 / 2847
页数:9
相关论文
共 50 条
  • [41] A prospective randomized trial comparing donor morbidity between filgrastim stimulated bone marrow and peripheral blood stem cell collection
    Baker, D
    Kennedy, G
    Western, R
    Durrant, S
    Morton, J
    BONE MARROW TRANSPLANTATION, 2003, 31 : S168 - S169
  • [42] Comparison of spectra optia and amicus cell separators for autologous peripheral blood stem cell collection
    Chung, Yousun
    Kong, Jung Hee
    Hu, Youmi
    Lee, Se-Na
    Shim, Hyoeun
    Eom, Hyeon-Seok
    Kong, Sun-Young
    JOURNAL OF CLINICAL APHERESIS, 2021, 36 (01) : 28 - 33
  • [43] Pharmacokinetic and pharmacodynamic study of lenograstim for hematopoietic stem cell mobilization: a prospective randomized study for optimal apheresis
    Kang, Jihoon
    Hong, Jung Yong
    Yoon, Dok Hyun
    Kim, Jeong Eun
    Kim, Kyu-pyo
    Kim, Shin
    Lee, Kyoung Min
    Park, Jung Sun
    Lee, Ji Sung
    Suh, Cheolwon
    TRANSFUSION, 2019, 59 (05) : 1781 - 1788
  • [44] Peripheral blood stem cell apheresis in normal donors: The neglected side
    Anderlini, P
    Przepiorka, D
    Champlin, R
    Korbling, M
    BLOOD, 1996, 88 (09) : 3663 - 3664
  • [45] Use of totally implantable catheters for peripheral blood stem cell apheresis
    L Carausu
    G Clapisson
    I Philip
    H Sebban
    P Marec-Bérard
    Bone Marrow Transplantation, 2007, 40 : 417 - 422
  • [46] Use of totally implantable catheters for peripheral blood stem cell apheresis
    Carausu, L.
    Clapisson, G.
    Philip, I.
    Sebban, H.
    Marec-Berard, P.
    BONE MARROW TRANSPLANTATION, 2007, 40 (05) : 417 - 422
  • [47] Use of totally implantable catheter for peripheral blood stem cell apheresis
    Carausu, L.
    Clapisson, G.
    Philip, I.
    Sebban, H.
    Marec-Berard, P.
    BONE MARROW TRANSPLANTATION, 2007, 39 : S131 - S131
  • [48] Peripheral blood progenitor cell apheresis increases circulating stem cells
    Chang, NB
    Pei, L
    Xu, XD
    Wei, HP
    Gu, XC
    Liu, H
    BLOOD, 2005, 106 (11) : 399B - 399B
  • [49] The influence of extracorporeal peripheral blood stem cell apheresis on platelet antigens
    Gutensohn, K
    Hummel, K
    Goepfert, C
    Riggert, J
    Cassens, U
    Kuehnl, P
    TRANSFUSIONSMEDIZIN 1996/97, 1997, 34 : 153 - 156
  • [50] Hypokalemia: A complication of peripheral blood stem cell (PBSC) apheresis.
    Ali, SM
    Bongiovani, M
    Ehmann, WC
    Gerhard, G
    Mierski, J
    Rybka, WB
    BLOOD, 1998, 92 (10) : 296B - 296B