MASS TRANSFER GAS-LIQUID IN COLUMN OF AERATION

被引:0
|
作者
Salla, Marcio Ricardo [1 ]
Schulz, Harry Edmar [2 ]
机构
[1] UFU Uberlandia, BR-38400902 Uberlandia, MG, Brazil
[2] USP, Sao Carlos, SP, Brazil
关键词
Aeration; diffuser; non-intrusive velocimetry; laser equipment; mass transfer gas-liquid;
D O I
10.1590/S1413-41522008000200009
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The present work is a study of the mass transfer gas-liquid from air bubbles into water, generated by a diffuser of air, in a column of aeration, changing the air flow from 400 L/h to 2000 L/h, the level of water from 0.50 m to 1.80 m, whose taxes of superficial application of air had varied of 3.1 L/m(2). s to 15.4 L/m(2). s. Several hydrodynamics characteristics were measured, such as the velocity range of the air bubbles and their diameter, fundamental to check the mass transfer coefficient that are in literature, by using a laser equipment for non-intrusive velocimetry. After of the study of the mass transfer, it was concluded that the air flow between 400 L/h and 800 L/h and the level of water of 1.80 m was the most efficient of mass transfer, guaranteeing for these measure, into of the column in study, most quantity of dissolved oxygen.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [21] Gas-liquid mass transfer approach applied to the modeling of flotation in a bubble column
    Chahed, Jamel
    M'Rabet, Kamel
    CHEMICAL ENGINEERING & TECHNOLOGY, 2008, 31 (09) : 1296 - 1303
  • [22] Effect of some solid properties on gas-liquid mass transfer in a bubble column
    Mena, P.
    Ferreira, A.
    Teixeira, J. A.
    Rocha, F.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2011, 50 (02) : 181 - 188
  • [23] Transient state techniques for mass transfer characterization of a gas-liquid packed column
    Perrin, S
    Chaudourne, S
    Jallut, C
    Lieto, J
    CHEMICAL ENGINEERING SCIENCE, 2002, 57 (16) : 3335 - 3345
  • [24] GAS-LIQUID MASS-TRANSFER IN A BUBBLE COLUMN WITH SUSPENDED NONWETTABLE SOLIDS
    SCHUMPE, A
    SAXENA, AK
    NIGAM, KDP
    AICHE JOURNAL, 1987, 33 (11) : 1916 - 1920
  • [25] GAS-LIQUID MASS-TRANSFER IN A BUBBLE COLUMN WITH SUSPENDED-SOLIDS
    NIGAM, KDP
    SCHUMPE, A
    AICHE JOURNAL, 1987, 33 (02) : 328 - 330
  • [26] Mass transfer in gas-liquid contactors
    Gaddis, ES
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1999, 38 (4-6) : 503 - 510
  • [27] Mass transfer in gas-liquid contactors
    Gaddis, E.S.
    Chemical Engineering and Processing, 1999, 38 (4-6): : 503 - 510
  • [28] Gas-liquid mass transfer in a slurry bubble column operated at gas hydrate forming conditions
    Hashemi, Shahrzad
    Macchi, Arturo
    Servio, Phillip
    CHEMICAL ENGINEERING SCIENCE, 2009, 64 (16) : 3709 - 3716
  • [29] Gas-Liquid Mass Transfer Characteristics with Microbubble Aeration - I. Standard Stirred Tank
    Li, Xiangyang
    Li, Pingping
    Zu, Liangzhu
    Yang, Chao
    CHEMICAL ENGINEERING & TECHNOLOGY, 2016, 39 (05) : 945 - 952
  • [30] Gas-liquid mass transfer using surface-aeration in stirred vessels, with dual impellers
    Lines, PC
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A3): : 342 - 347