MASS TRANSFER GAS-LIQUID IN COLUMN OF AERATION

被引:0
|
作者
Salla, Marcio Ricardo [1 ]
Schulz, Harry Edmar [2 ]
机构
[1] UFU Uberlandia, BR-38400902 Uberlandia, MG, Brazil
[2] USP, Sao Carlos, SP, Brazil
关键词
Aeration; diffuser; non-intrusive velocimetry; laser equipment; mass transfer gas-liquid;
D O I
10.1590/S1413-41522008000200009
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The present work is a study of the mass transfer gas-liquid from air bubbles into water, generated by a diffuser of air, in a column of aeration, changing the air flow from 400 L/h to 2000 L/h, the level of water from 0.50 m to 1.80 m, whose taxes of superficial application of air had varied of 3.1 L/m(2). s to 15.4 L/m(2). s. Several hydrodynamics characteristics were measured, such as the velocity range of the air bubbles and their diameter, fundamental to check the mass transfer coefficient that are in literature, by using a laser equipment for non-intrusive velocimetry. After of the study of the mass transfer, it was concluded that the air flow between 400 L/h and 800 L/h and the level of water of 1.80 m was the most efficient of mass transfer, guaranteeing for these measure, into of the column in study, most quantity of dissolved oxygen.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [2] Gas-liquid mass transfer in microbubble column reactors
    Xie, B. Q.
    Liu, W.
    Zhang, C. H.
    Chen, Y.
    Ma, W. Y.
    Zhang, J. S.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 202
  • [3] VOLUMETRIC GAS-LIQUID MASS-TRANSFER COEFFICIENTS IN A RECTANGULAR BUBBLE COLUMN WITH A RUBBER AERATION PAD
    MEDIC, L
    CEHOVIN, A
    KOLOINI, T
    PAVKO, A
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1989, 41 (03): : B51 - B54
  • [4] A Novel Surface Aeration Configuration for Improving Gas-Liquid Mass Transfer
    禹耕之
    毛在砂
    王蓉
    ChineseJournalofChemicalEngineering, 2002, (01) : 45 - 50
  • [5] A novel surface aeration configuration for improving gas-liquid mass transfer
    Yu, GZ
    Mao, ZS
    Wang, R
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2002, 10 (01) : 39 - 44
  • [6] GAS-LIQUID MASS-TRANSFER IN THE BUBBLE COLUMN WITH VISCOELASTIC LIQUID
    SUH, IS
    SCHUMPE, A
    DECKWER, WD
    KULICKE, WM
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (02): : 506 - 512
  • [7] GAS-LIQUID MASS-TRANSFER IN A SLURRY BUBBLE COLUMN
    SCHUMPE, A
    SAXENA, AK
    FANG, LK
    CHEMICAL ENGINEERING SCIENCE, 1987, 42 (07) : 1787 - 1796
  • [8] GAS-LIQUID MASS-TRANSFER IN A VIBRATING DISK COLUMN
    MIYANAMI, K
    TOJO, K
    MINAMI, I
    YANO, T
    CHEMICAL ENGINEERING SCIENCE, 1978, 33 (05) : 601 - 608
  • [9] Gas-liquid mass transfer enhancement in a surface aeration stirred slurry reactors
    Ruthiya, KC
    Kuster, BFM
    Schouten, JC
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 632 - 639
  • [10] MODELING OF THE GAS-LIQUID MASS-TRANSFER BY THE AERATION WITH LOW SOLUBLE GASES
    KUDREWIZKI, F
    CHEMISCHE TECHNIK, 1980, 32 (11): : 579 - 581