Prefabricated Versus Customized Abutments: A Retrospective Analysis of Loosening of Cement-Retained Fixed Implant-Supported Reconstructions

被引:14
|
作者
Korsch, Michael [1 ]
Walther, Winfried [2 ]
机构
[1] Dent Acad Continuing Profess Dev, Oral Surg, D-76135 Karlsruhe, Germany
[2] Dent Acad Continuing Profess Dev, D-76135 Karlsruhe, Germany
关键词
PERI-IMPLANTITIS; LUTING AGENTS; IN-VITRO; RESTORATIONS; RETENTION; CROWNS;
D O I
10.11607/ijp.4307
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this retrospective follow-up study was to determine whether implant-supported reconstructions on customized computer-milled abutments will loosen less frequently than those placed on prefabricated abutments. Materials and Methods: Suprastructures on prefabricated abutments (n = 312) were compared with those on customized computer-milled abutments (n = 96) over an observation period of 2 years. In all cases, the suprastructures had been cemented on the abutments with zinc oxide-eugenol cement (ZEC). Both groups were subdivided into single-crown restorations, fixed dental prostheses (FDPs) with two implants, and FDPs with more than two implants. The data were evaluated on the denture level. Results: Of the restorations on prefabricated abutments, 8% loosened, and of those on customized abutments, 3.1% loosened. The difference was not significant. Of the single crowns on prefabricated abutments, 7.7% loosened, and of those on customized abutments, 0% loosened. The difference was significant. For the FDPs with two implants (prefabricated abutments: 9.7%; customized abutments: 10.7%; not significant) and the FDPs with more than two implants (prefabricated abutments: 0%; customized abutments: 11.1%; significance not analyzed), statistical evaluation was difficult because of the small number of cases. Conclusions: Loosening of reconstructions placed on customized abutments can be reduced for single-crown restorations. When ZEC is used, customized abutments offer a valid alternative to prefabricated abutments. The small number of cases of FDPs with two implants and FDPs with more than two implants made statistical evaluation impossible.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 50 条
  • [11] USING DIGITALLY CODED HEALING ABUTMENTS AND AN INTRAORAL SCANNER TO FABRICATE IMPLANT-SUPPORTED, CEMENT-RETAINED RESTORATIONS
    Nayyar, Namrata
    Yilmaz, Burak
    McGlumphy, Edwin
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (04): : 210 - 215
  • [12] Use of prefabricated titanium abutments and customized anatomic lithium disilicate structures for cement-retained implant restorations in the esthetic zone
    Lin, Wei-Shao
    Harris, Bryan T.
    Zandinejad, Amirali
    Martin, William C.
    Morton, Dean
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03): : 181 - 185
  • [13] Fracture Strength of Implant-Supported Ceramic Crowns with Customized Zirconia Abutments: Screw Retained vs. Cement Retained
    Lima Verde Nogueira, Lorenna Bastos
    Vilarinho Soares Moura, Carmem Dolores
    Francischone, Carlos Eduardo
    Valente, Valdimar Silva
    Mendes Alencar, Suya Moura
    Moura, Walter Leal
    Soares Martins, Gregorio Antonio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (01): : 49 - 53
  • [14] Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation
    Shrivastav, Monica
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02): : 154 - 160
  • [15] The Effect of Different Surface Treatments on Cement-Retained Implant-Supported Restorations
    Kurt, Murat
    Kulunk, Tolga
    Ural, Cagri
    Kulunk, Safak
    Danisman, Sengul
    Savas, Soner
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (01) : 44 - 51
  • [16] A new prosthodontic technique for fabricating cement-retained implant-supported prostheses
    Wat, PYP
    Pow, EHN
    Chow, TW
    QUINTESSENCE INTERNATIONAL, 2000, 31 (03): : 187 - 190
  • [17] Multicenter retrospective study of cement-retained implant-supported anterior partial prostheses: Success and restoration evaluation
    Khraisat, Ameen
    Jebreen, Sami E.
    Baqain, Zaid H.
    Smadi, Leena
    Bakaeen, Lara
    Abu-Hammad, Osama
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (04) : 705 - 708
  • [18] An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses
    Pietrabissa, R
    Gionso, L
    Quaglini, V
    Di Martino, E
    Simion, M
    CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) : 448 - 457
  • [19] EFFECT OF AXIAL WALL MODIFICATION ON THE RETENTION OF CEMENT-RETAINED, IMPLANT-SUPPORTED CROWNS
    Tan, Kian M.
    Masri, Radi
    Driscoll, Carl F.
    Limkangwalmongkol, Penwadee
    Romberg, Elaine
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (02): : 80 - 85
  • [20] AN IN VITRO ASSESSMENT OF CIRCUMFERENTIAL GROOVES ON THE RETENTION OF CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS
    Lewinstein, Israel
    Block, Liat
    Lehr, Zachi
    Ormianer, Zeev
    Matalon, Shlomo
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (06): : 367 - 372