Assessment of an ultrasonic dermal scanner for skin thickness measurements

被引:10
|
作者
Kong, Linghua [1 ]
Caspall, Jayme [1 ]
Duckworth, Mark [1 ]
Spriale, Stephen [1 ]
机构
[1] Georgia Inst Technol, Coll Architecture, Ctr Assist Technol & Environm Access, Atlanta, GA 30332 USA
关键词
ultrasound technical assessment; dermal scanning; skin thickness;
D O I
10.1016/j.medengphy.2007.10.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement precision of a 20 MHz ultrasound dermal scanning system, Episcano(R), for its use in the measurement of skin thickness. Results from measurements of relatively ideal homogeneous, uniformly thick plastic plates indicate that the scanner can accurately measure to depths of 8-34 inm from the surface of the transducer or approximately 18 mm from the surface of the latex probe-cover with a high level of precision, less than 1% of the mean thickness. The precision was determined to be dependent on the depth of the scan. Using the measured optimal gain of 45%, a sample rate of 0.0 13 mu s, and an A-scan record length of 1024 points, we determined the thickness resolution of the device is on the order of 0.003 mm for 2 mm thick layers and 0.01 mm for 5 mm thick layers. We conclude that variations greater than this value for clinical dermal thickness measurements are not due to instrument precision, but must result from the limitations of analyzing the data from real tissue. (C) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:804 / 807
页数:4
相关论文
共 50 条
  • [21] The use of split-thickness dermal grafts to resurface full thickness skin defects
    Rubis, BA
    Danikas, D
    Neumeister, M
    Williams, WG
    Suchy, H
    Milner, SM
    BURNS, 2002, 28 (08) : 752 - 759
  • [22] Skin models for dermal exposure assessment of phthalates
    Olkowska, Ewa
    Grzinic, Goran
    CHEMOSPHERE, 2022, 295
  • [23] AN ULTRASONIC SCANNER
    GREATOREX, CA
    BRITISH JOURNAL OF RADIOLOGY, 1963, 36 (424): : 303 - 303
  • [24] Ultrasonic measurement of skin thickness in patients with systemic sclerosis
    Brocks, K
    Stender, I
    Karlsmark, T
    Ullman, S
    Halberg, P
    Jacobsen, S
    ACTA DERMATO-VENEREOLOGICA, 2000, 80 (01) : 59 - 60
  • [25] AVIATION FOCUSED EDDY-CURRENT AND ULTRASONIC SCANNER ASSESSMENT
    GIESKE, JH
    MATERIALS EVALUATION, 1995, 53 (07) : 820 - 826
  • [26] ASSESSMENT OF SKIN IRRITANCY - MEASUREMENT OF SKIN FOLD THICKNESS
    WAHLBERG, JE
    CONTACT DERMATITIS, 1983, 9 (01) : 21 - 26
  • [27] Validity and reliability of a structured-light 3D scanner and an ultrasound imaging system for measurements of facial skin thickness
    Lee, Kang-Woo
    Kim, Sang-Hwan
    Gil, Young-Chun
    Hu, Kyung-Seok
    Kim, Hee-Jin
    CLINICAL ANATOMY, 2017, 30 (07) : 878 - 886
  • [28] TEMPERATURE AND CONCENTRATION EFFECTS IN ULTRASONIC MEASUREMENTS OF CORNEAL THICKNESS
    BAIRD, JJ
    DYBBS, A
    GREBER, I
    HAZONY, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 145 - 145
  • [29] ULTRASONIC VELOCITY MEASUREMENTS IN THE THICKNESS DIRECTION OF PAPER.
    Habeger, C.C.
    1600, (32):
  • [30] ULTRASONIC VELOCITY-MEASUREMENTS IN THE THICKNESS DIRECTION OF PAPER
    HABEGER, CC
    WINK, WA
    JOURNAL OF APPLIED POLYMER SCIENCE, 1986, 32 (04) : 4503 - 4540