Echo-time range effects on gradient-echo based myelin water fraction mapping at 3T

被引:10
|
作者
Lee, Hongpyo [1 ]
Nam, Yoonho [2 ]
Kim, Dong-Hyun [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Radiol, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
IN-VIVO; RELAXATION; FREQUENCY; BRAIN; ORIENTATION; MODEL; VISUALIZATION; ATLAS; MRI;
D O I
10.1002/mrm.27564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the effect of the range of TE on multi-echo gradient echobased myelin water fraction (MWF) mapping at 3 T. Methods: Myelin water fraction estimation was performed using 3 widely used models: magnitude multipool, magnitude 3-pool, and complex 3-pool model. Simulations were conducted using a hollow cylinder model with susceptibility anisotropy. The TE range was varied, and its effect on MWF estimation was observed. The same analysis was also performed with in vivo data from 4 healthy volunteers. Results: Different MWFs were obtained depending on the range of TE data acquired. In the simulations, the results of both magnitude models had a bias with respect to the true values: a maximum bias of up to 20% for the multipool model, and a maximum bias of up to 8% for the 3-pool model. This bias was reduced using the complex 3-pool model (maximum bias was under 2%). These effects were also found in the in vivo data. The MWF values using the complex model was most stable with respect to the TE range. Conclusion: The results of the simulation and in vivo data suggest that MWF values fitted using magnitude models are more influenced by the TE range collected for fitting than using the complex model. The complex model is helpful in mitigating bias due to dependencies over the TE range selection.
引用
收藏
页码:2799 / 2807
页数:9
相关论文
共 50 条
  • [41] Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner
    Furuyama, Jon K.
    Burns, Brian L.
    Wilson, Neil E.
    Thomas, M. Albert
    MATERIALS, 2011, 4 (10): : 1818 - 1834
  • [42] Feasibility of Myelin Water Fraction Quantification Using Multi-Component Gradient Echo Sampling of Spin Echoes
    Gagnon, Y.
    Gelman, N.
    Theberge, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [43] Assessment of the myelin water fraction in rodent spinal cord using T2-prepared ultrashort echo time MRI
    Tim Klasen
    Cornelius Faber
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 875 - 884
  • [44] Optimizing variable flip angles in magnetization-prepared gradient-echo sequences for efficient 3D-T1ρ mapping
    Zibetti, Marcelo V. W.
    De Moura, Hector L.
    Keerthivasan, Mahesh B.
    Regatte, Ravinder R.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (04) : 1465 - 1483
  • [45] Phase-based T2 mapping with gradient echo imaging
    Wang, Xiaoke
    Hernando, Diego
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 609 - 619
  • [46] A Single-Scan T2* Mapping Method Based on Two Gradient-Echo Images with Compensation for Macroscopic Field Inhomogeneity
    Meng, Yuguang
    Lei, Hao
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1388 - 1395
  • [47] Assessment of the myelin water fraction in rodent spinal cord using T2-prepared ultrashort echo time MRI
    Klasen, Tim
    Faber, Cornelius
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (06) : 875 - 884
  • [48] Assessment of ultrashort echo time (UTE) T2* mapping at 3T for the whole knee: repeatability, the effects of fat suppression, and knee position
    Wu, Zhenzhou
    Zaylor, William
    Sommer, Stefan
    Xie, Dongxing
    Zhong, Xiaodong
    Liu, Kecheng
    Kim, Jeehun
    Beveridge, Jillian E.
    Zhang, Xiaoliang
    Li, Xiaojuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 7893 - 7909
  • [49] Optimizing variable flip angles in magnetization-prepared gradient-echo sequences for efficient 3D-T1ρ mapping
    Zibetti, Marcelo V. W.
    De Moura, Hector L.
    Keerthivasan, Mahesh B.
    Regatte, Ravinder R.
    MAGNETIC RESONANCE IN MEDICINE, 2023,
  • [50] A single-point dixon technique for fat-suppressed fast 3D gradient-echo Imaging with a flexible echo time
    Ma, Jingfei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 881 - 890