Robotic Vertebral Puncture System for Percutaneous Vertebroplasty

被引:7
|
作者
Onogi, Shinya [1 ]
Nakajima, Yoshikazu [2 ]
Koyama, Tsuyoshi [3 ]
Tamura, Yuichi [4 ]
Kobayashi, Etsuko [5 ]
Sakuma, Ichiro [5 ]
Sugano, Nobuhiko [6 ]
Yonenobu, Kazuo [3 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, Koganei, Tokyo 1838538, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Bioengn, Tokyo 1138654, Japan
[3] Osaka Minami Hosp, Osaka 5400006, Japan
[4] Toyonaka City Hosp, Osaka 5608565, Japan
[5] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Tokyo 1138654, Japan
[6] Osaka Univ, Grad Sch Med, Dept Organ Regulat Med, Suita, Osaka 5650871, Japan
关键词
Surgical robotics; Minimally invasive surgery; X-ray-translucent mechanism; Passive failsafe mechanism; HIP-REPLACEMENT;
D O I
10.5405/jmbe.954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A robotic system with an X-ray-translucent end-effector and a passive failsafe mechanism is proposed for percutaneous vertebroplasty (PVP). The proposed system consists of a puncture robot with five degrees of freedom, a workstation for the navigation system, and an optical tracking device. The end-effector of the robot is partially X-ray translucent to allow the needle insertion process to be monitored by an X-ray fluoroscope. The robot has a passive failsafe mechanism for safety purposes. A needle assembly is attached to the robot by four asymmetric contacting parts supported by four springs. To evaluate the puncture accuracy of the system, puncture tests were conducted on 50 pedicles of five polyurethane phantoms simulating human lumbar vertebrae from L1 to L5. Pre-operative computed tomography (CT) volumes were acquired for the respective phantoms and segmented. Surgical plans were made for the respective pedicles by a surgeon. After the system was placed at the experimental table's side and the phantom was fixed on the table, robot calibration and phantom registration were performed. During the experiments, no needles were found to be protruding from the pedicles. The positioning accuracy measured by the optical tracking device was 0.64 mm root-mean-square (RMS) and 1.09 degrees RMS (error range = 0.1-0.98 mm, 0.96-1.36 degrees). After the tests, postoperative CT volumes of the respective phantoms were acquired and the puncture trajectories were analyzed. The puncture errors between the planned and actual trajectories were 1.66 mm RMs and 1.62 degrees RMS (error range = 0.13-4.21 mm, 0.36-2.73 degrees). The results demonstrate the feasibility of safe and accurate punctures with the proposed system.
引用
收藏
页码:491 / 496
页数:6
相关论文
共 50 条
  • [31] Is percutaneous vertebral augmentation (vertebroplasty) effective treatment for painful vertebral fractures?
    Watts, NB
    AMERICAN JOURNAL OF MEDICINE, 2003, 114 (04): : 326 - 328
  • [32] Comparison of targeted percutaneous vertebroplasty and traditional percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures in the elderly
    Lingli Yuan
    Jianzhong Bai
    Chunhui Geng
    Guansheng Han
    Wendi Xu
    Zhongchuan Zhang
    Hong Luo
    Xunbing Zhu
    Journal of Orthopaedic Surgery and Research, 15
  • [33] Comparison of targeted percutaneous vertebroplasty and traditional percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures in the elderly
    Yuan, Lingli
    Bai, Jianzhong
    Geng, Chunhui
    Han, Guansheng
    Xu, Wendi
    Zhang, Zhongchuan
    Luo, Hong
    Zhu, Xunbing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [34] Percutaneous vertebroplasty: a novel treatment for acute vertebral fractures
    Diamond, TH
    Clark, WA
    MEDICAL JOURNAL OF AUSTRALIA, 2001, 174 (08) : 398 - 400
  • [35] Conversion to hypertrophic vertebral pseudarthrosis following percutaneous vertebroplasty
    Satoshi Kawaguchi
    Keiko Horigome
    Hideki Yajima
    Takashi Oda
    Yuichiro Kii
    Mitsunori Yoshimoto
    Tsuneo Takebayashi
    Toshihiko Yamashita
    European Spine Journal, 2010, 19 : 901 - 906
  • [36] Conversion to hypertrophic vertebral pseudarthrosis following percutaneous vertebroplasty
    Kawaguchi, Satoshi
    Horigome, Keiko
    Yajima, Hideki
    Oda, Takashi
    Kii, Yuichiro
    Yoshimoto, Mitsunori
    Takebayashi, Tsuneo
    Yamashita, Toshihiko
    EUROPEAN SPINE JOURNAL, 2010, 19 (06) : 901 - 906
  • [37] The reactions of PMMA in vertebral body after percutaneous vertebroplasty
    Li, Chun-Hai
    Zhang, Shuo-Ling
    Ding, Yue
    Ye, Wei
    Zhu, Wei-rong
    Lou, Zhen-kai
    BONE, 2010, 47 : S427 - S427
  • [38] Percutaneous Cement Vertebroplasty in the Treatment of Symptomatic Vertebral Hemangiomas
    Hao, Jie
    Hu, ZhenMing
    PAIN PHYSICIAN, 2012, 15 (01) : 43 - 49
  • [39] Percutaneous vertebroplasty: option of treatment for osteoporotic vertebral fracture
    Figueiredo, N
    Amaral, JC
    Serra, AD
    Nogueira, AM
    Garcia, VCS
    Weissheimer, FL
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2003, 61 (3A) : 625 - 630
  • [40] Percutaneous vertebroplasty: New treatment for vertebral compression fractures
    Predey, TA
    Sewall, LE
    Smith, SJ
    AMERICAN FAMILY PHYSICIAN, 2002, 66 (04) : 611 - 615