Robotic Vertebral Puncture System for Percutaneous Vertebroplasty

被引:7
|
作者
Onogi, Shinya [1 ]
Nakajima, Yoshikazu [2 ]
Koyama, Tsuyoshi [3 ]
Tamura, Yuichi [4 ]
Kobayashi, Etsuko [5 ]
Sakuma, Ichiro [5 ]
Sugano, Nobuhiko [6 ]
Yonenobu, Kazuo [3 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, Koganei, Tokyo 1838538, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Bioengn, Tokyo 1138654, Japan
[3] Osaka Minami Hosp, Osaka 5400006, Japan
[4] Toyonaka City Hosp, Osaka 5608565, Japan
[5] Univ Tokyo, Grad Sch Engn, Dept Precis Engn, Tokyo 1138654, Japan
[6] Osaka Univ, Grad Sch Med, Dept Organ Regulat Med, Suita, Osaka 5650871, Japan
关键词
Surgical robotics; Minimally invasive surgery; X-ray-translucent mechanism; Passive failsafe mechanism; HIP-REPLACEMENT;
D O I
10.5405/jmbe.954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A robotic system with an X-ray-translucent end-effector and a passive failsafe mechanism is proposed for percutaneous vertebroplasty (PVP). The proposed system consists of a puncture robot with five degrees of freedom, a workstation for the navigation system, and an optical tracking device. The end-effector of the robot is partially X-ray translucent to allow the needle insertion process to be monitored by an X-ray fluoroscope. The robot has a passive failsafe mechanism for safety purposes. A needle assembly is attached to the robot by four asymmetric contacting parts supported by four springs. To evaluate the puncture accuracy of the system, puncture tests were conducted on 50 pedicles of five polyurethane phantoms simulating human lumbar vertebrae from L1 to L5. Pre-operative computed tomography (CT) volumes were acquired for the respective phantoms and segmented. Surgical plans were made for the respective pedicles by a surgeon. After the system was placed at the experimental table's side and the phantom was fixed on the table, robot calibration and phantom registration were performed. During the experiments, no needles were found to be protruding from the pedicles. The positioning accuracy measured by the optical tracking device was 0.64 mm root-mean-square (RMS) and 1.09 degrees RMS (error range = 0.1-0.98 mm, 0.96-1.36 degrees). After the tests, postoperative CT volumes of the respective phantoms were acquired and the puncture trajectories were analyzed. The puncture errors between the planned and actual trajectories were 1.66 mm RMs and 1.62 degrees RMS (error range = 0.13-4.21 mm, 0.36-2.73 degrees). The results demonstrate the feasibility of safe and accurate punctures with the proposed system.
引用
收藏
页码:491 / 496
页数:6
相关论文
共 50 条
  • [1] Accuracy of vertebral puncture in percutaneous vertebroplasty
    Noguchi, Tomoyuki
    Yamashita, Koji
    Shida, Yoshitaka
    Okafuji, Takashi
    Kamei, Ryotaro
    Maehara, Junki
    Tajima, Tsuyoshi
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (04) : 419 - 429
  • [2] Accuracy of vertebral puncture in percutaneous vertebroplasty
    Tomoyuki Noguchi
    Koji Yamashita
    Yoshitaka Shida
    Takashi Okafuji
    Ryotaro Kamei
    Junki Maehara
    Tsuyoshi Tajima
    Japanese Journal of Radiology, 2022, 40 : 419 - 429
  • [3] Precise puncture combined with simplified percutaneous vertebroplasty to treat osteoporotic vertebral compression fractures: a comparative analysis with conventional percutaneous vertebroplasty
    Pang, Jutao
    Liu, Bin
    Chen, Hong
    Zhang, Wei
    Sun, Jianhua
    Zhang, Xinhu
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (12): : 14195 - 14202
  • [4] Vertebral Osteonecrosis and Percutaneous Vertebroplasty
    Rossello, Lluis
    Palliso, Francesc
    Ferrer, Jesus
    Docampo, Elisa
    Calvet, Joan
    Benito, Pere
    Serra, Joan
    REUMATOLOGIA CLINICA, 2008, 4 (04): : 162 - 165
  • [5] Optimizing percutaneous vertebroplasty: extra-facet puncture for osteoporotic vertebral compression fractures
    Zheng, Huo-Liang
    Li, Bo
    Jiang, Qin-Yu
    Jiang, Lei-Sheng
    Zheng, Xin-Feng
    Jiang, Sheng-Dan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [6] Optimizing percutaneous vertebroplasty: extra-facet puncture for osteoporotic vertebral compression fractures
    Huo-Liang Zheng
    Bo Li
    Qin-Yu Jiang
    Lei-Sheng Jiang
    Xin-Feng Zheng
    Sheng-Dan Jiang
    Journal of Orthopaedic Surgery and Research, 18
  • [7] Percutaneous vertebroplasty for vertebral compression fracture
    Kawanishi, Masahiro
    Itoh, Yutaka
    Satoh, Daisuke
    Matsuda, Nahoko
    Kamo, Masatsugu
    Handa, Hajime
    NEUROLOGICAL SURGERY, 2006, 34 (08): : 793 - 799
  • [8] PERCUTANEOUS VERTEBROPLASTY FOR OSTEOPOROTIC VERTEBRAL FRACTURES
    Bautista Del Valle, Juan
    Miguel Galich, Facundo
    Adrian Borensztein, Matias
    Gustavo Petracchi, Matias
    ACTUALIZACIONES EN OSTEOLOGIA, 2022, 18 (01) : 29 - 39
  • [9] Percutaneous vertebroplasty for thoracic vertebral metastases
    李健
    黄海
    潘永谦
    张平
    杨波
    莫世奋
    中国矫形外科杂志, 2011, 19 (11) : 912 - 917
  • [10] Percutaneous vertebroplasty for single osteoporotic vertebral body compression fractureResults of unilateral 3-D percutaneous puncture technique
    Hong-De Li
    Chuan-Jun Xu
    Hong Wang
    Wen Liu
    Xi-Jing Jiang
    Xi-Qi Zhu
    Indian Journal of Orthopaedics, 2015, 49 : 245 - 250