Immediate loading of modular transitional implants: A histologic and histomorphometric study in dogs

被引:0
|
作者
Zubery, Y
Bichacho, N
Moses, O
Tal, H [1 ]
机构
[1] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Periodontol, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Prosthet Dent, IL-69978 Tel Aviv, Israel
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Modular Transitional implants (MTI) are made from pure titanium and are used to support fixed provisional restorations during the osseointegration of definitive implants. This study histologically examined We jaw response to loaded MTls in We dog mandible. Three implants were inserted transmucosally into each side of We mandible in 3 dogs. Stability was examined using a Perlotest. Anterior and posterior implants were splinted using a cemented acrylic resin tired partial denture to allow immediate loading. The middle implant remained unloaded and was used as a control. Dogs were sacrificed 11 to 72 weeks after implantation, and tissue blocks containing the implants were removed. Histologic examination showed that 70 of the 18 implants had good bone-to-implant contact, with the percentage of bone contacting We threaded portion of the implant varying from 30% to 65%. There was no statistical difference (P > 0.1) in percentage of bone-to-metal contact between loaded and unloaded implants. Six implants were entirely surrounded by connective tissue with or without inflammation; two implants were lost during the study The success rate did not differ between loaded and unloaded implants. in the successful implants trabecular bone made good contact with We implant, forming supporting struts. There was bone remodeling in some bone-to-metal contact areas, if is believed that success was mainly influenced by the initial bone density at the implant site and by the uncontrolled load that We animals applied to We implants during the early healing stage.
引用
收藏
页码:343 / 353
页数:11
相关论文
共 50 条
  • [11] Histologic and histomorphometric evaluation of new zirconia-based ceramic dental implants: A preclinical study in dogs
    Chacun, Doriane
    Lafon, Arnaud
    Courtois, Nicolas
    Reveron, Helen
    Chevalier, Jerome
    Margossian, Patrice
    Alves, Antoine
    Gritsch, Kerstin
    Grosgogeat, Brigitte
    DENTAL MATERIALS, 2021, 37 (09) : 1377 - 1389
  • [12] Osseointegration of Osseotite® and machined titanium implants in autogenous bone graft.: A histologic and histomorphometric study in dogs
    Veis, AA
    Trisi, P
    Papadimitriou, S
    Tsirlis, AT
    Parissis, NA
    Desiris, AK
    Lazzara, RJ
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (01) : 54 - 61
  • [13] The Effects of Different Loading Times on the Bone Response Around Dental Implants: A Histomorphometric Study in Dogs
    Jayme, Sergio Jorge
    de Oliveira, Rafael Ramos
    Muglia, Valdir Antonio
    Novaes, Arthur Belem, Jr.
    Ribeiro, Ricardo Faria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 473 - 481
  • [14] Immediate loading of orthodontic mini-implants: a histomorphometric evaluation of tissue reaction
    Luzi, Cesare
    Verna, Carlalberta
    Melsen, Birte
    EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (01) : 21 - 29
  • [15] Influence of implant microstructure on the osseointegration of immediate implants placed in periodontally infected sites - A histomorphometric study in dogs
    Novaes, AB
    Papalexiou, V
    Grisi, MFM
    Souza, SSLS
    Taba, M
    Kajiwara, JK
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (01) : 34 - 43
  • [16] Immediate placement of implants into periodontally infected sites in dogs: A histomorphometric study of bone-implant contact
    Novaes, AB
    Marcaccini, AM
    Souza, SLS
    Taba, M
    Grisi, MFM
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 391 - 398
  • [17] Immediate placement and loading of dental implants: A human histologic case report
    Guida, Luigi
    Iezzi, Giovanna
    Annunziata, Marco
    Salierno, Antonio
    Iuorio, Giovanni
    Costigliola, Giorgio
    Piattelli, Adriano
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (03) : 575 - 581
  • [18] Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading:: An experimental study with Macaca fascicularis
    Romanos, GE
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (01) : 44 - 51
  • [19] Immediate loading of implants with various coatings in beagle dogs.
    Sirota, CA
    Fiorellini, J
    Corso, M
    Weber, HP
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 3059 - 3059
  • [20] Use of 3 transitional implants as stabilization aid for predictable immediate loading of implants in the edentulous mandible
    Wu, Aaron Yu-Jen
    Chee, Winston
    QUINTESSENCE INTERNATIONAL, 2006, 37 (08): : 627 - 631