Design optimization of a 2D prompt-gamma measurement system for proton dose verification

被引:8
|
作者
Lee, Han Rim [1 ]
Park, Jong Hoon [1 ]
Kim, Chan Hyeong [1 ]
Min, Chul Hee [2 ,3 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
基金
新加坡国家研究基金会;
关键词
Proton therapy; Prompt-gamma; Range verification; Monte Carlo; MCNPX; MONTE-CARLO; RANGE VERIFICATION; THERAPY;
D O I
10.3938/jkps.61.239
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To verify in-vivo proton dose distribution, a 2-dimensional (2D) prompt-gamma measurement system, comprised of a multi-hole collimation system, a 2D array of CsI(Tl) scintillators, and a position-sensitive photomultiplier tube (PS-PMT), is under development. In the present study, to determine the optimal dimension of the measurement system, we employed a series of Monte Carlo simulations with the MCNPX code. To effectively measure the high-energy prompt gammas while minimizing background gammas, we determined the collimator hole size, collimator thickness, and scintillator length to be 0.4 x 0.4 cm(2), 15 cm, and 5 cm, respectively. Thereafter, the performance of the optimized measurement system was estimated for monoenergetic proton pencil beams. The peak locations of the prompt-gamma distributions for 80- and 150-MeV proton beams were clearly distinguished, and the correlation between the beam range and the peak location was confirmed by using the measurement system. For a 200-MeV proton beam, however, the peak location could not be determined due to the dominance of background gammas and the lateral dispersion of the proton beam at the end of the beam range. Based on these simulation results, a prototype 2D prompt-gamma measurement system currently is under construction and, upon completion, will be tested with therapeutic proton beams.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [21] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    J. Balibrea-Correa
    J. Lerendegui-Marco
    I. Ladarescu
    C. Guerrero
    T. Rodríguez-González
    M. C. Jiménez-Ramos
    B. Fernández-Martínez
    C. Domingo-Pardo
    The European Physical Journal Plus, 137
  • [22] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    Balibrea-Correa, J.
    Lerendegui-Marco, J.
    Ladarescu, I
    Guerrero, C.
    Rodriguez-Gonzalez, T.
    Jimenez-Ramos, M. C.
    Fernandez-Martinez, B.
    Domingo-Pardo, C.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (11):
  • [23] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [24] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [25] A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy
    Draeger, E.
    Chen, H.
    Mackin, D.
    Peterson, S.
    Avery, S.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [26] Development of a new prompt gamma ray detection system for full 3D proton range verification
    Costanza, P.
    Mackay, R. I.
    Kirkby, K. J.
    Taylor, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S957 - S958
  • [27] Prompt gamma-ray imaging with a nuclear emulsion for in vivo dose verification in proton therapy
    Toshito, Toshiyuki
    Kimura, Mitsuhiro
    Ogino, Hiroyuki
    Shibamoto, Yuta
    Nakamura, Mitsuhiro
    Sato, Osamu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [28] Prompt-gamma neutron activation analysis system design: Effects of D-T versus D-D neutron generator source selection
    Shypailo, R. J.
    Ellis, K. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 71 - 77
  • [29] Prompt-gamma neutron activation analysis system design: Effects of D-T versus D-D neutron generator source selection
    R. J. Shypailo
    K. J. Ellis
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 71 - 77
  • [30] Translation of a prompt gamma based proton range verification system to first clinical application
    Richter, C.
    Pausch, G.
    Barczyk, S.
    Priegnitz, M.
    Golnik, C.
    Bombelli, L.
    Enghardt, W.
    Fiedler, F.
    Fiorini, C.
    Hotoiu, L.
    Janssens, G.
    Keitz, I.
    Mein, S.
    Perali, I.
    Prieels, D.
    Smeets, J.
    Thiele, J.
    Vander Stappen, F.
    Werner, T.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S214 - S214