Design optimization of a 2D prompt-gamma measurement system for proton dose verification

被引:8
|
作者
Lee, Han Rim [1 ]
Park, Jong Hoon [1 ]
Kim, Chan Hyeong [1 ]
Min, Chul Hee [2 ,3 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
基金
新加坡国家研究基金会;
关键词
Proton therapy; Prompt-gamma; Range verification; Monte Carlo; MCNPX; MONTE-CARLO; RANGE VERIFICATION; THERAPY;
D O I
10.3938/jkps.61.239
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To verify in-vivo proton dose distribution, a 2-dimensional (2D) prompt-gamma measurement system, comprised of a multi-hole collimation system, a 2D array of CsI(Tl) scintillators, and a position-sensitive photomultiplier tube (PS-PMT), is under development. In the present study, to determine the optimal dimension of the measurement system, we employed a series of Monte Carlo simulations with the MCNPX code. To effectively measure the high-energy prompt gammas while minimizing background gammas, we determined the collimator hole size, collimator thickness, and scintillator length to be 0.4 x 0.4 cm(2), 15 cm, and 5 cm, respectively. Thereafter, the performance of the optimized measurement system was estimated for monoenergetic proton pencil beams. The peak locations of the prompt-gamma distributions for 80- and 150-MeV proton beams were clearly distinguished, and the correlation between the beam range and the peak location was confirmed by using the measurement system. For a 200-MeV proton beam, however, the peak location could not be determined due to the dominance of background gammas and the lateral dispersion of the proton beam at the end of the beam range. Based on these simulation results, a prototype 2D prompt-gamma measurement system currently is under construction and, upon completion, will be tested with therapeutic proton beams.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [1] Design optimization of a 2D prompt-gamma measurement system for proton dose verification
    Han Rim Lee
    Jong Hoon Park
    Chan Hyeong Kim
    Chul Hee Min
    Journal of the Korean Physical Society, 2012, 61 : 239 - 242
  • [2] Two-dimensional measurement of the prompt-gamma distribution for proton dose distribution monitoring
    Han Rim Lee
    Jong Hoon Park
    Han Sung Kim
    Chan Hyeong Kim
    Seonghoon Kim
    Journal of the Korean Physical Society, 2013, 63 : 1385 - 1389
  • [3] Two-dimensional measurement of the prompt-gamma distribution for proton dose distribution monitoring
    Lee, Han Rim
    Park, Jong Hoon
    Kim, Han Sung
    Kim, Chan Hyeong
    Kim, Seonghoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1385 - 1389
  • [4] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [5] EXPERIMENTAL VERIFICATION OF KEY CROSS SECTIONS FOR PROMPT-GAMMA IMAGING IN PROTON THERAPY
    Wronska, A.
    Ahmed, A. Anees
    Andres, A.
    Bednarczyk, P.
    Besuglow, J.
    Gazdowicz, G.
    Herweg, K.
    Hetzel, R.
    Kasper, J.
    Kelleter, L.
    Konefal, A.
    Kulessa, P.
    Laihem, K.
    Leidner, J.
    Magiera, A.
    Rusiecka, K.
    Stachura, D.
    Stahl, A.
    Zieblinski, M.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1631 - 1637
  • [6] A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy
    Ready, I.
    Pak, R.
    Mihailescu, L.
    Vetter, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3678 - 3678
  • [7] Evaluation of strategies for dose reconstruction from prompt-gamma radiation in proton therapy
    Foglia, B.
    Gianoli, C.
    Masuda, T.
    Bortfeld, T.
    Verburg, J.
    Parodi, K.
    Pinto, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1540 - S1542
  • [8] Deep Learning-Based Prompt-Gamma Imaging for Range Verification in Proton Radiotherapy
    Jiang, Z.
    Polf, J.
    Ren, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E210 - E210
  • [9] Range verification in proton therapy: Can prompt-gamma imaging identify the source of deviation?
    Khamfongkhruea, C.
    Janssens, G.
    Petzoldt, J.
    Smeets, J.
    Pausch, G.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S296 - S297
  • [10] Optimisation of a Prompt-Gamma Slit Imaging System for Particle Beam Range Verification
    Vella, A.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S122 - S122