Accurate On-line Estimation of Delivered Dialysis Dose by Dialysis Adequacy Monitor (DIAMON)

被引:0
|
作者
Fridolin, I. [1 ]
Jerotskaja, J. [1 ]
Lauri, K. [1 ]
Scherbakov, A. [1 ]
Luman, M. [2 ]
机构
[1] Tallinn Univ Technol, Dept Biomed Engn Technomed, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] North Estonian Regional Hosp, Dept Dialysis & Nephrol, EE-13419 Tallinn, Estonia
关键词
hemodialysis; dialysis dose; dialysis quality; dialysis monitoring; absorbance;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to compare equilibrated urea Kt/V (eKt/V) from the slope of the logarithmic on-line UV-absorbance measurements measured by the Dialysis Adequacy Monitor (DIAMON), by eKt/N obtained from a new algorithm that can be implemented into the DIAMON prototype. As the reference the urea eKt/V was utilized obtained from the blood samples according to the rate adjustment method. The mean value of equilibrated Kt/V obtained with UV-absorbance (eKt/Va) was 1.06 +/- 0.21, using the new algorithm (eKt/Vn) was 1.09 +/- 0.18, and eKt/N from blood-urea (eKt/Vb) 1.09 +/- 0.20 (N = 21). The mean values of eKt/N were not statistically different comparing different methods. However, both the systematic and the random error were diminished by the new algorithm. The systematic error was decreased from 2.19% to 0.312%, and the random error was decreased from 14.37% to 7.30% using the new algorithm. In summary, the DIAMON prototype can accurately and on-line estimate the dialysis dose.
引用
收藏
页码:350 / +
页数:2
相关论文
共 50 条
  • [21] Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification
    Bosticardo, G.M.
    Avalle, U.
    Giacchino, F.
    Molino, A.
    Alloatti, S.
    1600, J.B. Lippincott Co, Hagerstown, MD, United States (40):
  • [22] Producing On-Line Ultrapure Dialysis Fluid
    von Albertini, Beat
    ON-LINE HEMODIAFILTRATION: THE JOURNEY AND THE VISION, 2011, 175 : 46 - 56
  • [23] Adequacy of delivered dialysis doses in the HEMO study: An interim report.
    Eknoyan, G
    Agodoa, L
    Beck, G
    Daugirdas, J
    Greene, T
    Kusek, J
    Levin, N
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A1296 - A1296
  • [24] Adequacy of dialysis; Accurate prediction based on simple equations.
    Hussain, AS
    Manis, T
    Carvounis, CP
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A1328 - A1328
  • [25] The Tesio dialysis catheter: A prospective analysis of radiologic placement, mechanical performance, and adequacy of delivered dialysis in the chronic setting
    Perini, S
    LaBerge, JM
    Pearl, J
    Santiestiban, H
    Kerlan, RK
    Wilson, MW
    RADIOLOGY, 1998, 209P : 454 - 455
  • [26] Peritoneal fluid agitation and dialysis dose estimation in automatic peritoneal dialysis
    Esteve, V.
    Ponz, E.
    Marquina, D.
    Blasco, C.
    Ocana, J. C. Martinez
    Mane, N.
    Garcia, M.
    NEFROLOGIA, 2006, 26 (02): : 267 - 269
  • [27] Determination of the dose of dialysis with integrated modules in the same monitor
    Torregrosa, E.
    Hernandez-Jaras, J.
    Garcia-Perez, H.
    Pons-Prades, R.
    Calvo-Gordo, C.
    Rius-Peris, A.
    Sanchez-Canel, J. J.
    Pin-Godos, M.
    NEFROLOGIA, 2006, 26 (02): : 246 - 252
  • [28] On-line hemodiafiltration in a small dialysis facility.
    Finch, CD
    Finch, JC
    Graves, BE
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A0744 - A0744
  • [29] On-line hemodiaifiltration: The most effective dialysis modality
    Vaslaki, L.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (08): : 700 - 700
  • [30] Using the Intelligent System to Improve the Delivered Adequacy of Dialysis by Preventing Intradialytic Complications
    Karimi, Mohammad
    Dideban, Daryoosh
    Heidari, Hadi
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022