Accurate On-line Estimation of Delivered Dialysis Dose by Dialysis Adequacy Monitor (DIAMON)

被引:0
|
作者
Fridolin, I. [1 ]
Jerotskaja, J. [1 ]
Lauri, K. [1 ]
Scherbakov, A. [1 ]
Luman, M. [2 ]
机构
[1] Tallinn Univ Technol, Dept Biomed Engn Technomed, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] North Estonian Regional Hosp, Dept Dialysis & Nephrol, EE-13419 Tallinn, Estonia
关键词
hemodialysis; dialysis dose; dialysis quality; dialysis monitoring; absorbance;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to compare equilibrated urea Kt/V (eKt/V) from the slope of the logarithmic on-line UV-absorbance measurements measured by the Dialysis Adequacy Monitor (DIAMON), by eKt/N obtained from a new algorithm that can be implemented into the DIAMON prototype. As the reference the urea eKt/V was utilized obtained from the blood samples according to the rate adjustment method. The mean value of equilibrated Kt/V obtained with UV-absorbance (eKt/Va) was 1.06 +/- 0.21, using the new algorithm (eKt/Vn) was 1.09 +/- 0.18, and eKt/N from blood-urea (eKt/Vb) 1.09 +/- 0.20 (N = 21). The mean values of eKt/N were not statistically different comparing different methods. However, both the systematic and the random error were diminished by the new algorithm. The systematic error was decreased from 2.19% to 0.312%, and the random error was decreased from 14.37% to 7.30% using the new algorithm. In summary, the DIAMON prototype can accurately and on-line estimate the dialysis dose.
引用
收藏
页码:350 / +
页数:2
相关论文
共 50 条
  • [1] Dialysis dose and nutrition assessment by optical on-line dialysis adequacy monitor
    Luman, M.
    Jerotskaja, J.
    Lauri, K.
    Fridolin, I.
    CLINICAL NEPHROLOGY, 2009, 72 (04) : 303 - 311
  • [2] Accurate estimation of delivered dialysis dose by on-line ultra violet absorbance in the spent dialysate
    Fridolin, Ivo
    Uhlin, Fredrik
    Lindberg, Lars-Goran
    Magnusson, Martin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 424 - 424
  • [3] Multicenter clinical validation of an on-line monitor of dialysis adequacy
    Depner, TA
    Keshaviah, PR
    Ebben, JP
    Emerson, PF
    Collins, AJ
    Jindal, KK
    Nissenson, AR
    Lazarus, JM
    Pu, K
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (03): : 464 - 471
  • [4] On-line clearance: Advanced methodology to monitor adequacy of dialysis at no cost
    Gotch, FA
    HEMODIALYSIS TECHNOLOGY, 2002, 137 : 268 - 271
  • [5] Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate
    Uhlin, F
    Fridolin, I
    Lindberg, LG
    Magnusson, M
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2003, 41 (05) : 1026 - 1036
  • [6] On-line assessment of delivered dialysis dose - Technical note
    Di Filippo, S
    Andrulli, S
    Manzoni, C
    Corti, M
    Locatelli, F
    KIDNEY INTERNATIONAL, 1998, 54 (01) : 263 - 267
  • [7] Conductivity: on-line monitoring of dialysis adequacy
    Del Vecchio, L
    Di Filippo, S
    Andrulli, S
    Manzoni, C
    Corti, M
    Barbisoni, F
    Locatelli, F
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (09): : 521 - 525
  • [8] Time spent on dialysis: The paramount consideration in dialysis adequacy? A new application for the BioStat 1000 on-line urea monitor
    Basham, LM
    Agar, JWM
    DIALYSIS & TRANSPLANTATION, 1997, 26 (11) : 739 - &
  • [9] Dialysis Dose and Adequacy
    不详
    INDIAN JOURNAL OF NEPHROLOGY, 2020, 30 : 44 - 45
  • [10] Dialysis dose as a determinant of adequacy
    Daugirdas, JT
    Greene, T
    SEMINARS IN NEPHROLOGY, 2005, 25 (02) : 76 - 80