Calibration of the CMS electromagnetic calorimeter with LHC collision data

被引:0
|
作者
Obertino, M. M. [1 ,2 ]
机构
[1] Univ Piemonte Orientale, Novara, Italy
[2] Ist Nazl Fis Nucl, I-10125 Turin, Italy
基金
英国科学技术设施理事会;
关键词
Electromagnetic calorimeter; Calibration; CMS;
D O I
10.1016/j.nima.2012.11.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CMS ECAL is a high resolution electromagnetic calorimeter which relies upon precision calibration in order to achieve and maintain its design performance. Variations in light collected from the lead tungstate crystals, due to intrinsic differences in crystals/photodetectors, as well as variations with time due to radiation damage for example, need to be taken into account. Sophisticated and effective methods of inter-crystal and absolute calibration have been devised, using collision data from the 2011 LHC run and a dedicated light injection system. For inter-calibration, low mass particle (pi(0) and eta) decays to two photons are exploited, as well as the azimuthal symmetry of the average energy deposition at a given pseudorapidity. The light injection system monitors the channel response in real-time and enables the re-calibration of the measured energies over time. This is cross-checked by the comparison of E/p measurements of electrons from W decays (where the momentum is measured in the CMS tracker) with/without these re-calibrations applied. Absolute calibration has been performed using Z decays into electron-positron pairs. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 101
页数:3
相关论文
共 50 条
  • [31] Final calibration results of CMS electromagnetic calorimeter photodetectors
    Depasse, P.
    El Mamouni, H.
    Fay, J.
    Gascon-Shotkin, S.
    Ille, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 242 - 245
  • [32] Commissioning, Performance and Calibration of Crystals of the CMS Electromagnetic Calorimeter
    Yang, Yong
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,
  • [34] Calibration and Performance of the ATLAS Level-1 Calorimeter Trigger with LHC Collision Data
    Wessels, Martin
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1841 - 1848
  • [35] The CMS crystal calorimeter for the LHC
    Zach, F
    HIGH ENERGY PHYSICS, VOLS I AND II, 2001, : 1254 - 1256
  • [36] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. -L.
    Gras, P.
    Mandjavidze, L.
    Busson, P.
    Paganini, P.
    2007 15TH IEEE-NPSS REAL-TIME CONFERENCE, VOLS 1 AND 2, 2007, : 571 - +
  • [37] The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
    Obertino, M. M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [38] The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC
    Gras, Philippe
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [39] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. L.
    Gras, P.
    Mandjavidze, I.
    Busson, P.
    Paganini, P.
    JOURNAL OF INSTRUMENTATION, 2008, 3 (02)
  • [40] Data quality monitoring for the CMS electromagnetic calorimeter
    Cossutti, F.
    Della Ricca, G.
    Franzoni, G.
    Ghezzi, A.
    Gobbo, B.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 177 : 289 - 290