Value of positron emission tomography for lung cancer staging

被引:14
|
作者
Albes, JM
Dohmen, BM
Schott, U
Schülen, E
Wehrmann, M
Ziemer, G
机构
[1] Univ Tubingen, Div Thorac Cardiac & Vasc Surg, D-72074 Tubingen, Germany
[2] Univ Tubingen, Div Nucl Med, D-72074 Tubingen, Germany
[3] Univ Tubingen, Div Diagnost Radiol, D-72074 Tubingen, Germany
[4] Univ Tubingen, Dept Internal Med, D-72074 Tubingen, Germany
[5] Univ Tubingen, Dept Pathol, D-72074 Tubingen, Germany
来源
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY | 2002年 / 28卷 / 01期
关键词
2 '-[F-18]fluoro-2 '-deoxyglucose; positron emission tomography; computed tomography; non-small-cell lung cancer; staging;
D O I
10.1053/ejso.2001.1144
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: The therapeutic strategy in non-small-cell lung cancer (NSCLC) requires exact staging of tumour invasion (T) as well as differentiation between ipsi- and contralateral lymph node invasion (N1/2 vs N3). [F-18]FDG-positron emission tomography (FDG-PET) has been shown to detect invaded N with high accuracy while correct determination of T appears to be unclear. The purpose of this prospective study was to evaluate benefit and necessity of (18)FDG-PET as an additive to conventional staging modalities. Methods: Forty patients with suspected non-small-cell lung cancer (NSCLC) were staged by means of computed tomography (CT), bronchoscopy, mediastinoscopy and bone scintigraphy. Additionally, attenuation corrected FDG-PET of the thorax was performed pre-operatively for analysis of T and N topography. After surgical resection with radical lymphadenectomy T and N staging results of CT and PET were compared with the pathological diagnoses. Specificity, sensitivity, positive predictive value and accuracy of CT and PET were calculated. Results: Twenty three squamous cell carcinomas, 14 adenocarcinomas, and three non-malignant tumours were found. Accuracy of CT-T was 0.75 and of PET-T 0.78; accuracy of CT-N was 0.78 and of PET-N 0.80. By combination of CT-T and PET-T accuracy was 0.88. Combination of CT-N and PET-N yielded an accuracy of 0.90. In two out of three cases, PET correctly determined TO. In two cases non-malignant inflammatory lymph nodes were falsely staged as malignant by PET. Conclusions: Adequate pre-operative T- and N-staging is possible with both CT and FDG-PET. Accuracy can be improved by combination of CT and FDG-PET. FDG-PET is superior to CT in order to differentiate between malignant and benign tumours. However, acute inflammation can mimic malignant lymph node invasion. FDG-PET is justified as a supporting staging measure in cases presenting unclear differentiation between N2 and N3 after conventional staging and is helpful in cases with unclear cell type of the primary tumour. (C) 2001 Harcourt Publishers Ltd.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [11] Positron Emission Tomography in Staging Early Lung Cancer A Randomized Trial
    Maziak, Donna E.
    Darling, Gail E.
    Inculet, Richard I.
    Gulenchyn, Karen Y.
    Driedger, Albert A.
    Ung, Yee C.
    Miller, John D.
    Gu, Chu-Shu
    Cline, Kathryn J.
    Evans, William K.
    Levine, Mark N.
    ANNALS OF INTERNAL MEDICINE, 2009, 151 (04) : 221 - W48
  • [12] Fluorodeoxyglucose-positron emission tomography in the detection and staging of lung cancer
    Sazon, DAD
    Santiago, SM
    Hoo, GWS
    Khonsary, A
    Brown, C
    Mandelkern, M
    Blahd, W
    Williams, AJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (01) : 417 - 421
  • [13] Indications for positron emission tomography and bone gammagraphy in staging lung cancer
    Cabrera-Rodriguez, Joaquin
    Garcia-Bernardo, Lucia
    Quiros-Rivero, Juan
    ARCHIVOS DE BRONCONEUMOLOGIA, 2012, 48 (08): : 300 - 300
  • [14] Staging of the mediastinum: Value of positron emission tomography imaging in non-small cell lung cancer
    Bury, T
    Paulus, P
    Dowlati, A
    Corhay, JL
    Weber, T
    Ghaye, B
    Schoffers, J
    Limet, R
    Albert, A
    Rigo, P
    Radermecker, M
    EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (12) : 2560 - 2564
  • [15] The Impact Of Positron Emission Tomography On The Staging And Outcome Of Small Cell Lung Cancer
    Li, S. -H.
    Kao, K. -C.
    Ho, K. -C.
    Lee, C. -S.
    Hsu, P. -C.
    Li, L. -F.
    Huang, C. -C.
    Liu, C. -Y.
    Chen, N. -H.
    Yang, C. -T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [16] Positron emission tomography (PET) and combined imaging modalities for staging lung cancer
    Scott, WJ
    SURGICAL CLINICS OF NORTH AMERICA, 2002, 82 (03) : 477 - +
  • [17] Positron emission tomography in the diagnosis and staging of lung cancer: a systematic, quantitative review
    Fischer, BMB
    Mortensen, J
    Hojgaard, L
    LANCET ONCOLOGY, 2001, 2 (11): : 659 - 666
  • [18] Indications for positron emission tomography and bone gammagraphy in staging lung cancer Reply
    De Cos Escuin, Julio Sanchez
    Hernandez Hernandez, Jesus
    Jimenez Lopez, Marcelo F.
    Padrones Sanchez, Susana
    Rosell Gratacos, Antoni
    Rami Porta, Ramon
    ARCHIVOS DE BRONCONEUMOLOGIA, 2012, 48 (08): : 301 - 301
  • [19] Positron Emission Tomography/Computed Tomography in Lung Cancer Staging, Prognosis, and Assessment of Therapeutic Response
    Truong, Mylene T.
    Viswanathan, Chitra
    Erasmus, Jeremy J.
    JOURNAL OF THORACIC IMAGING, 2011, 26 (02) : 132 - 146
  • [20] Is there a role for positron emission tomography/computed tomography in the staging of small-cell lung cancer?
    Truong, Mylene T.
    Marom, Edith M.
    CLINICAL LUNG CANCER, 2008, 9 (01) : 8 - 8