Operation of the negative ion-based neutral beam injection system during Large Helical Device experimental campaigns

被引:3
|
作者
Oka, Y [1 ]
Kaneko, O [1 ]
Takeiri, Y [1 ]
Tsumori, K [1 ]
Osakabe, M [1 ]
Ikeda, K [1 ]
Asano, E [1 ]
Kawamoto, T [1 ]
Akiyama, R [1 ]
Hamabe, M [1 ]
机构
[1] Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
Large Helical Devices (LHD); neutral beam injection (NBI); tangential; tokamak;
D O I
10.1016/S0920-3796(01)00344-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Large Helical Device (LHD) is the only machine that relies upon negative ion-based neutral beam injection system (NBI) as the principal heating power source. Since the first injection in 1998, NBI has been used to heat over 3000 shots for 2 years. Performance has progressed step by step to reach an injection power of 4.5 MW, with beam energy up to 165 keV, and pulse lengths up to 80 s at 0.5 MW. System operating level has reached similar to 30% of the design power and similar to 65% of the H(-) design current. This tangential high-energy NBI system based on negative ions has proved to be as efficient a heating system in a helical device as in a tokamak. The ratio of injection neutral beam power to high voltage drain power (injection power efficiency) was typically about 0.3. This is a low efficiency compared to the design one. For long pulse injection beam blocking (such as observed on PLT) was encountered, but it did not limit the operation. In order to achieve the design output of 15 MW. a great R&D effort is underway on the negative ion test stand to improve the performance of 40 A 180 keV negative hydrogen ion source. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 50 条
  • [31] Neutron characterization analysis of the negative ion-based neutral beam verification facility for CFETR
    Chen, Yuqing
    Wang, Ji
    Wu, Bin
    Yang, Zhen
    Li, Jun
    Wang, Jinfang
    Liang, Lizhen
    Zhang, Hong
    Xie, Yuanlai
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [32] Design and implementation of the digital twin system for the negative ion based neutral beam injection
    Gu, Yu
    Hu, Chundong
    Zhao, Yuanzhe
    Li, Yang
    Cui, Qinglong
    Bai, Ruoxin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (08)
  • [33] Z dependence of neutral beam driven current in the large helical device and the compact helical system
    Nagaoka, Kenichi
    Watanabe, Kiyomasa
    Ida, Katsumi
    Yoshinuma, Mikiro
    Kobuchi, Takashi
    Narushima, Yoshiro
    Toi, Kazuo
    Isobe, Mitsutaka
    Shimizu, Akihiro
    Minami, Takashi
    Akiyama, Tsuyoshi
    Matsuoka, Keisuke
    Okamura, Shoichi
    Ikeda, Katsunori
    Osakabe, Masaki
    Tsumori, Katsuyoshi
    Oka, Yoshihide
    Takeiri, Yasuhiko
    Kaneko, Osamu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2006, 49 : S92 - S95
  • [34] High power beam injection using an improved negative on source for the large helical device
    Tsumori, K
    Nagaoka, K
    Osakabe, M
    Takeiri, Y
    Ikeda, K
    Kaneko, O
    Oka, Y
    Kawamoto, T
    Asano, E
    Sato, M
    Kondo, T
    Asano, S
    Suzuki, Y
    Okuyama, T
    Ichihashi, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1847 - 1850
  • [35] Development of large RF driven negative ion sources for neutral beam injection
    Kraus, W
    McNeely, P
    Franzen, P
    Entscheva, A
    Bandyopadhyay, M
    Heinemann, B
    Riedl, R
    Speth, E
    Wilhelm, R
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 491 - 495
  • [36] Status of the heavy ion beam probe system in the Large Helical Device
    Nishiura, M.
    Ido, T.
    Shimizu, A.
    Nakano, H.
    Kato, T.
    Kato, S.
    Hamada, Y.
    Shevelko, V. P.
    Janev, R. K.
    Wada, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [37] Initial long-pulse plasma heating at reduced power with negative-ion-based neutral beam injector in large helical device
    Takeiri, Y
    Noda, N
    Nakamura, Y
    Oka, Y
    Osakabe, M
    Kawahata, K
    Kaneko, O
    Tsumori, K
    Sato, M
    Mutoh, T
    Goto, M
    Ida, K
    Inagaki, S
    Kado, S
    Masuzaki, S
    Morita, S
    Nagayama, Y
    Peterson, BJ
    Sagara, A
    Sakakibara, S
    Sato, K
    Tanaka, K
    Sudo, S
    Ohyabu, N
    Motojima, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4260 - 4265
  • [38] Response of plasmas to tungsten pellet injection in neutral beam heated discharges in large helical device
    Oishi T.
    Morita S.
    Huang X.
    Liu Y.
    Goto M.
    Oishi, TeTsutarou (oishi@nifs.ac.jp), 2018, Japan Society of Plasma Science and Nuclear Fusion Research (13)
  • [39] Response of Plasmas to Tungsten Pellet Injection in Neutral Beam Heated Discharges in Large Helical Device
    Oishi, Tetsutarou
    Morita, Shigeru
    Huang, Xianli
    Liu, Yang
    Goto, Motoshi
    PLASMA AND FUSION RESEARCH, 2018, 13
  • [40] Two-dimensional beam emission spectroscopy for hydrogen isotope negative neutral beam in Large Helical Device
    Kobayashi, T.
    Yoshinuma, M.
    Ida, K.