Operation of the negative ion-based neutral beam injection system during Large Helical Device experimental campaigns

被引:3
|
作者
Oka, Y [1 ]
Kaneko, O [1 ]
Takeiri, Y [1 ]
Tsumori, K [1 ]
Osakabe, M [1 ]
Ikeda, K [1 ]
Asano, E [1 ]
Kawamoto, T [1 ]
Akiyama, R [1 ]
Hamabe, M [1 ]
机构
[1] Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
Large Helical Devices (LHD); neutral beam injection (NBI); tangential; tokamak;
D O I
10.1016/S0920-3796(01)00344-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Large Helical Device (LHD) is the only machine that relies upon negative ion-based neutral beam injection system (NBI) as the principal heating power source. Since the first injection in 1998, NBI has been used to heat over 3000 shots for 2 years. Performance has progressed step by step to reach an injection power of 4.5 MW, with beam energy up to 165 keV, and pulse lengths up to 80 s at 0.5 MW. System operating level has reached similar to 30% of the design power and similar to 65% of the H(-) design current. This tangential high-energy NBI system based on negative ions has proved to be as efficient a heating system in a helical device as in a tokamak. The ratio of injection neutral beam power to high voltage drain power (injection power efficiency) was typically about 0.3. This is a low efficiency compared to the design one. For long pulse injection beam blocking (such as observed on PLT) was encountered, but it did not limit the operation. In order to achieve the design output of 15 MW. a great R&D effort is underway on the negative ion test stand to improve the performance of 40 A 180 keV negative hydrogen ion source. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 50 条
  • [1] Engineering prospects of negative-ion-based neutral beam injection system from high power operation for the large helical device
    Kaneko, O
    Takeiri, Y
    Tsumori, K
    Oka, Y
    Osakabe, M
    Ikeda, K
    Nagaoka, K
    Kawamoto, T
    Asano, E
    Sato, M
    NUCLEAR FUSION, 2003, 43 (08) : 692 - 699
  • [2] Conceptional design of photoneutralization test system for negative ion-based neutral beam injection
    Hong, Hui-hui
    Liang, Li-zhen
    Xie, Yuan-lai
    Wang, Qian-xu
    Pan, Zhuo
    Jiang, Yao
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (01)
  • [3] Development of negative ion based neutral beam injector for the large helical device
    Kaneko, O
    Takeiri, Y
    Tsumori, K
    Oka, Y
    Osakabe, M
    Akiyama, R
    Kawamoto, T
    Asano, E
    Kuroda, T
    FUSION ENERGY 1996, VOL 3, 1997, : 539 - 545
  • [4] Extension of high power deuterium operation of negative ion based neutral beam injector in the large helical device
    Ikeda, K.
    Tsumori, K.
    Nagaoka, K.
    Nakano, H.
    Kisaki, M.
    Fujiwara, Y.
    Kamio, S.
    Haba, Y.
    Masaki, S.
    Osakabe, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):
  • [5] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y
    Osakabe, M
    Tsumori, K
    Oka, Y
    Kaneko, O
    Asano, E
    Kawamoto, T
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 977 - 979
  • [6] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y.
    Osakabe, M.
    Tsumori, K.
    Oka, Y.
    Kaneko, O.
    Asano, E.
    Kawamoto, T.
    Akiyama, R.
    Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [7] Auto-Recording System for Long-Pulse Negative Ion-Based Neutral Beam Injection Experimental Data
    Li, Y.
    Hu, C. D.
    Zhao, Y. Z.
    Song, S. H.
    Xie, Y. H.
    Gu, Y.
    Wang, Z.
    Ban, T.
    Cui, Q. L.
    FUSION SCIENCE AND TECHNOLOGY, 2024, 80 (06) : 772 - 780
  • [8] High-ion temperature experiments with negative-ion-based neutral beam injection heating in Large Helical Device
    Takeiri, Y
    Morita, S
    Tsumori, K
    Ikeda, K
    Oka, Y
    Osakabe, M
    Nagaoka, K
    Goto, M
    Miyazawa, J
    Masuzaki, S
    Ashikawa, N
    Yokoyama, M
    Murakami, S
    Narihara, K
    Yamada, R
    Kubo, S
    Shimozuma, T
    Inagaki, S
    Tanaka, K
    Peterson, BJ
    Ida, K
    Kaneko, O
    Komori, A
    NUCLEAR FUSION, 2005, 45 (07) : 565 - 573
  • [9] Thermal analysis and optimization of the calorimeter verification prototype of a negative ion-based neutral beam injection system
    Tang, Ning
    Hu, Chun-dong
    Xie, Yuan-lai
    Tao, Ling
    Zhang, Si
    Liu, Xiao-Xue
    Wang, Ming-Xiang
    Lang, Jia-Qi
    FUSION ENGINEERING AND DESIGN, 2022, 176
  • [10] Improvement of a large negative ion source for the Large Helical Device neutral beam injector
    Takeiri, Y
    Ikeda, K
    Hamabe, M
    Osakabe, M
    Kaneko, O
    Oka, Y
    Tsumori, K
    Asano, E
    Kawamoto, T
    Sato, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 1087 - 1089