Dosimetric advantages of volumetric modulated arc therapy (VMAT) with deep inspiration breath hold (DIBH) technique in Halcyon Linac for left breast cancer treatment

被引:1
|
作者
Cheung, Alex Pui-yin [1 ]
Lei, Michelle Man-i [2 ]
Lee, Sau-sing [1 ]
Hung, Wai-ki [1 ]
Chiu, Chun-wang [1 ]
Qiu, Xi-bin [2 ]
Chau, Ricky Ming-chun [1 ,2 ]
机构
[1] Tung Wah Coll, Sch Med & Hlth Sci, Hong Kong, Peoples R China
[2] Kiang Wu Hosp, Dept Oncol, Macau, Peoples R China
关键词
VMAT; Breast cancer; Halcyon; Heart dose; Deep inspiration breath hold; HEART; RADIOTHERAPY; IRRADIATION; LUNG;
D O I
10.1016/j.meddos.2022.04.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the dosimetric advantages of incorporating the deep inspiration breath hold (DIBH) technique into left breast cancer volumetric modulated arc therapy (VMAT) treatment under Halcyon Linac and to investigate the correlation between mean heart dose (MHD) and distance from the heart to target vol-umes in left breast cancer VMAT treatment. Fifteen Post-lumpectomy, left-sided breast patients treated between January 2017 and October 2020 were selected. Two plans were generated for each patient using Eclipse treatment planning system (TPS) with the prescription of 50.4 Gy to planning target volume (PTV) breast and 58.8 Gy to PTV boost in 28 fractions. For each patient, DIBH and free breathing (FB) VMAT treatment plans under Halcyon Linac were generated. Dosimetric parameters, monitor unit and beam -on time of both DIBH and FB groups were compared. Three-dimensional distances from heart surface to each target volume were measured on computed tomography images using the TPS contouring tool and their correlation with MHD was evaluated by Pearson's correlation coefficient ( r ). Comparable target coverage was shown in both groups. Mean dose to heart, left anterior descending artery, and left ven-tricle in Halcyon-DIBH-VMAT group were significantly reduced by 0.49 Gy, 1.19 Gy, and 0.57 Gy, respec-tively, compared to Halcyon-FB-VMAT ( p < 0.001). A significant lung dose reduction was also achieved in Halcyon-DIBH-VMAT group. There was also a strong negative correlation between MHD and distance from heart surface to PTV boost in both FB and DIBH group ( r = -0.741, p < 0.001), but not observed for distance from heart surface to PTV breast. Incorporating DIBH into left breast cancer VMAT treatment under Halcyon Linac demonstrated significant cardiac and lung dose reduction. It was also demonstrated that MHD had a strong negative correlation with distance from heart surface to PTV boost but relatively independent of distance from heart surface to PTV breast. Recognizing the distance from the heart surface to PTV boost as the main factor in affecting MHD could potentially facilitate clinical treatment planning workflow and decision.(c) 2022 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 50 条
  • [21] Reduction in low-dose to normal tissue with the addition of deep inspiration breath hold (DIBH) to volumetric modulated arc therapy (VMAT) in breast cancer patients with implant reconstruction receiving regional nodal irradiation
    Vishruta A. Dumane
    Kitwadee Saksornchai
    Ying Zhou
    Linda Hong
    Simon Powell
    Alice Y. Ho
    Radiation Oncology, 13
  • [22] Deep inspiration breath-hold (DIBH) radiotherapy in left-sided breast cancer
    Hepp, Rodrigo
    Ammerpohl, Mark
    Morgenstern, Christina
    Nielinger, Lisa
    Erichsen, Patricia
    Abdallah, Abdallah
    Galalae, Razvan
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (09) : 710 - 716
  • [23] Feasibility Study of Deep Inspiration Breath-Hold Based Volumetric Modulated Arc Therapy for Locally Advanced Left Sided Breast Cancer Patients
    Swamy, Shanmugam Thirumalai
    Radha, Chandrasekaran Anu
    Kathirvel, Murugesan
    Arun, Gandhi
    Subramanian, Shanmuga
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (20) : 9033 - 9038
  • [24] Heart sparing with deep inspiration breath hold (DIBH) in left breast treatment: a prospective study
    Vanoni, V.
    Mussari, S.
    Bossi, L.
    Coelli, F.
    Maino, M.
    Martignano, A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1156 - S1157
  • [25] Deep Inspiration Breath Hold (DIBH) as a standard option in left breast cancer patient (LBCP)
    Huscher, A.
    Donadoni, L.
    Taddeo, A.
    Galelli, M.
    Prochilo, T.
    Guerini, F.
    Mutti, S.
    Zaniboni, A.
    Bignardi, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S501 - S501
  • [26] Optimized Volumetric Modulated Arc Therapy (VMAT) Technique for Left Sided Breast Cancer Comprehensive Radiation Therapy Via the Halcyon Delivery System
    Goddu, S.
    Laugeman, E.
    Hilliard, J.
    Heermann, A.
    Cai, B.
    Mutic, S.
    Hugo, G.
    Zoberi, I.
    MEDICAL PHYSICS, 2019, 46 (06) : E359 - E359
  • [27] Advantages of deep inspiration breath-hold (DIBH) in left sided breast cancer using 3D-CRT
    Kalmar, A.
    Meszaros, N.
    Stelczer, G.
    Polgar, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S983 - S983
  • [28] Phase II study of deep inspiration breath hold (DIBH) and intensity modulated radiation therapy (IMRT) treatment for women with left-sided breast cancer
    Wai, E. S.
    Wells, D.
    Bendorffe, B.
    Runkel, J.
    Beckham, W.
    Popescu, C.
    McDonald, R.
    Olivotto, I. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S90 - S90
  • [29] Evaluation of abches and volumetric modulated arc therapy under deep inspiration breath-hold technique for patients with left-sided breast cancer A retrospective observational study
    Yeh, Tien-Chi
    Chi, Mau-Shin
    Chi, Kwan-Hwa
    Hsu, Chung-Hsien
    MEDICINE, 2019, 98 (39)
  • [30] PHASE II STUDY OF DEEP INSPIRATION BREATH HOLD (DIBH) AND INTENSITY MODULATED RADIATION THERAPY (IMRT) TREATMENT FOR WOMEN WITH LEFT-SIDED BREAST CANCER
    Wai, E. S.
    Wells, D.
    Bendorffe, B.
    Runkel, J.
    Beckham, W.
    Popescu, C.
    McDonald, R.
    Olivotto, I. A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S42 - S43