Comparison of Geant4 Version 9.3 Simulations with Experimental Results from a Prototype Proton CT Scanner

被引:0
|
作者
Milhoretto, Edney [1 ]
Schelin, Hugo R. [1 ,2 ]
Evseev, Ivan [1 ]
Paschuk, Sergei A. [1 ]
Setti, Joao A. [1 ,3 ]
Junior, Sebastiao R. [1 ]
Silva, Fabricio L. [1 ]
Lourenso, Jose C. [1 ]
Denyak, Valeriy [2 ]
de Assis, Joaquim
Yevseyeva, Olga [3 ]
Lopes, Ricardo [4 ]
Hurley, Ford [5 ]
Schulte, Reinhard [5 ]
机构
[1] Fed Univ Technol Parana UTFPR, BR-80230901 Curitiba, Parana, Brazil
[2] Pele Pequeno Principe Res Inst IPPP, BR-80250060 Curitiba, Parana, Brazil
[3] State Univ Rio de Janeiro UERJ, BR-28630050 Nova Friburgo, RJ, Brazil
[4] Univ Fed Rio de Janeiro, BR-21941914 Rio De Janeiro, RJ, Brazil
[5] Loma Linda Univ, Med Ctr, Loma Linda, CA USA
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
TOMOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Charged particle interactions with matter have been continuously studied by simulations based on the Monte Carlo method. In particular, the Geant4 toolkit allows to develop and test new technologies by computer simulations. A proton computed tomography (pCT) prototype has been developed at the Loma Linda University Medical Center (LLUMC), California, in collaboration with Northern Illinois University and the UC Santa Cruz. In order to evaluate the performance of the Geant4 version 9.3 configured to simulate this prototype, two polyethylene phantoms (PEA D) with 150 mm diameter and acrylic core were constructed. Each phantom was imaged with 10 projections by rotating the phantom in steps of 36, using a 200 MeV proton cone beam. The characteristics of the prototype and phantoms were modeled in Geant4. A comparison of the experimental data and simulated projections were performed and will be presented.
引用
收藏
页码:1000 / 1002
页数:3
相关论文
共 50 条
  • [21] HARP–CDP hadroproduction data: comparison with FLUKA and GEANT4 simulations
    A. Bolshakova
    I. Boyko
    G. Chelkov
    D. Dedovitch
    A. Elagin
    D. Emelyanov
    M. Gostkin
    A. Guskov
    Z. Kroumchtein
    Yu. Nefedov
    K. Nikolaev
    A. Zhemchugov
    F. Dydak
    J. Wotschack
    A. De Min
    V. Ammosov
    V. Gapienko
    V. Koreshev
    A. Semak
    Yu. Sviridov
    E. Usenko
    V. Zaets
    The European Physical Journal C, 2010, 70 : 543 - 553
  • [22] GEANT4 simulation in proton medical imaging: A transport models comparison
    Silva, R. C. L.
    Denyak, V.
    Hoff, G.
    Paschuk, S. A.
    Schelin, H. R.
    Setti, J. A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [23] Ray Tracing Simulations In Scintillators: a Comparison Between SLitrani and Geant4
    Pizzichemi, Marco
    Auffray, Etiennette
    Chipaux, Remi
    Cucciati, Giacomo
    Di Vara, Nicolas
    Ghezzi, Alessio
    Iaconelli, Riccardo
    Lecoq, Paul
    Lucchini, Marco Toliman
    Knapitsch, Arno
    Paganoni, Marco
    Pauwels, Kristof
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1712 - 1716
  • [24] Towards a response function for the COSI anticoincidence system: preliminary results from Geant4 simulations
    Ciabattoni, Alex
    Fioretti, Valentina
    Tomsick, John
    Zoghlauer, Andreas
    Jean, Pierre
    Franco, Daniel Alvarez
    von Ballmoos, Peter
    Bulgarelli, Andrea
    Vignali, Cristian
    Parmiggiani, Nicole
    Panebianco, Gabriele
    Castaldini, Luca
    SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093
  • [25] Comparison of experimental proton-induced fluorescence spectra for a selection of thin high-Z samples with Geant4 Monte Carlo simulations
    Incerti, S.
    Barberet, Ph.
    Deves, G.
    Michelet, C.
    Francis, Z.
    Ivantchenko, V.
    Mantero, A.
    El Bitar, Z.
    Bernal, M. A.
    Tran, H. N.
    Karamitros, M.
    Seznec, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 358 : 210 - 222
  • [26] Results from ATLAS Tile Calorimeter: a comparison between data and Geant4 simulation
    Dotti, A
    Lupi, A
    Roda, C
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 106 - 109
  • [27] Comparison of GEANT4 simulations with testbeam data and GEANT3 for the ATLAS liquid argon calorimeter
    Benchekroun, D
    Karapetian, G
    Mazini, R
    Kiryunin, A
    Salihagic, D
    Kish, J
    Strizenec, P
    Kordas, K
    Parrour, G
    Leltchouk, M
    Negroni, S
    Seligman, W
    Simion, S
    Loch, P
    Soukharev, A
    PROCEEDINGS OF CHEP 2001, 2001, : 350 - 353
  • [28] A DIGITAL HEAD PHANTOM FOR SIMULATIONS OF AN EXPERIMENTAL PROTON CT SCANNER
    Selchau, A.
    Choe, M.
    Gonzales, D.
    Giacometti, V
    Schulte, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (01) : 215 - 216
  • [29] Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE
    Grevillot, Loic
    Frisson, Thibault
    Zahra, Nabil
    Bertrand, Damien
    Stichelbaut, Frederic
    Freud, Nicolas
    Sarrut, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (20): : 3295 - 3305
  • [30] GEANT4 Simulations of 92Mo as a Range Verification Marker for Proton Radiotherapy
    Kasanda, E.
    Burbadge, C.
    Muecher, D.
    Hoehr, C.
    Bildstein, V.
    Turko, J.
    Mampaso, B. Olaizola
    MEDICAL PHYSICS, 2019, 46 (06) : E291 - E291