Improved effective damping equation for equivalent linear analysis of seismic-isolated bridges

被引:4
|
作者
Dicleli, M [1 ]
Buddaram, S
机构
[1] Middle E Tech Univ, Dept Engn Sci, TR-06531 Ankara, Turkey
[2] Bradley Univ, Dept Civil Engn & Construct, Peoria, IL 61625 USA
关键词
D O I
10.1193/1.2150187
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, an improved effective damping (ED) equation is proposed to obtain more reasonable estimates of the actual nonlinear response of seismic-isolated bridges (SIB) using equivalent linear (EL) analysis procedure. For this purpose, first the EL analysis results using AASHTO's ED equation is evaluated using harmonic and seismic ground motions. The effect of several parameters such as substructure stiffness, isolator properties, and the intensity and frequency characteristics of the ground motion are considered in the evaluation. Next, the effect of the superstructure mass on the ED ratio is studied. It is found that the accuracy of the EL analysis results is affected by the frequency characteristics and intensity of the ground motion. It is also demonstrated that AASHTO's ED equation should incorporate the effective period of the SIB and isolator properties for a more accurate estimation of the seismic response quantities. A new ED equation that includes such parameters is formulated and found to improve the accuracy of the EL analysis.
引用
收藏
页码:29 / 46
页数:18
相关论文
共 50 条
  • [31] Cost-benefit analysis of seismic-isolated structures with viscous damper based on loss estimation
    Banazadeh, Mehdi
    Gholhaki, Majid
    Sani, Hossein Parvini
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2017, 13 (08) : 1045 - 1055
  • [32] Damping Value for Seismic Response Analysis of Long-span Bridges
    Yu, Ling-Ling
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 1522 - 1525
  • [33] An improved equivalent linear model of seismic isolation system with bilinear behavior
    Liu, Tao
    Zordan, Tobia
    Briseghella, Bruno
    Zhang, Qilin
    ENGINEERING STRUCTURES, 2014, 61 : 113 - 126
  • [34] Seismic response analysis of bridges isolated with friction pendulum bearings
    Wang, Yen-Po
    Chung, Lap-Loi
    Liao, Wei-Hsin
    Earthquake Engineering and Structural Dynamics, 1998, 27 (10): : 1069 - 1093
  • [35] Seismic response analysis of bridges isolated with friction pendulum bearings
    Wang, YP
    Chung, LL
    Liao, WH
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (10): : 1069 - 1093
  • [36] Simplified analysis on seismic response of seismically isolated highway bridges
    Li, Chuang
    Ye, Aijun
    Yu, Maofeng
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2014, 35 (11): : 1339 - 1344
  • [37] Seismic Analysis of Urban Elevated Continuous Bridges Installed Different Damping Devices
    Ma, Lijun
    Xu, Jianming
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 983 - 986
  • [38] Uncertain seismic response and robustness analysis of isolated continuous girder bridges
    Long, Xiaohong
    Li, Zonglin
    Gu, Xiaopeng
    Chen, Xingwang
    Ma, Yongtao
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (15) : 2733 - 2749
  • [39] Improved equivalent viscous damping model for base-isolated structures with lead rubber bearings
    Zordan, Tobia
    Liu, Tao
    Briseghella, Bruno
    Zhang, Qilin
    ENGINEERING STRUCTURES, 2014, 75 : 340 - 352
  • [40] Calculation of effective additional damping ratio of energy dissipation structure based on linear equivalent method
    Wang, Qi
    Gan, Gang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2012, 33 (11): : 46 - 52