Neutral Grounding via Low Resistance Step Voltage Calculation and Simulation

被引:0
|
作者
Ci, Yanan [1 ]
Niu, Shengsuo [1 ]
Liang, Zhirui [1 ]
机构
[1] North China Elect Power Univ, Baoding, Peoples R China
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the neutral point grounding via low resistance short circuit fault current single-phase ground short circuit fault were calculated and analyzed. The ground current will cause large step voltage, thus threatening the safety of pedestrians. In this paper, this step voltage uneven soil model of theoretical calculations and the use of finite element software to simulate the step voltage. Studying area neutral resistance grounding influence into the soil depth, soil resistivity, capacitance and other factors on the step voltage, step voltage underground cables for single- phase ground fault simulation. And it puts forward the measure of reducing step voltage, the step voltage to minimize the harm of human body.
引用
收藏
页码:65 / 69
页数:5
相关论文
共 50 条
  • [1] Step Voltage Calculation Above the Horizontal Grounding Electrode
    Doric, Vicko
    Poljak, Dragan
    Hrboka, Ljubomir
    2024 9TH INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES, SPLITECH 2024, 2024,
  • [2] Neutral Grounding in Middle Voltage Power Systems: Simulation model
    Ravlic, S.
    Marusic, A.
    Havelka, J.
    2015 8TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2015, : 1124 - 1130
  • [3] APPLYING HIGH RESISTANCE NEUTRAL GROUNDING IN MEDIUM VOLTAGE SYSTEMS
    Kingrey, Lawrence J.
    Painter, Ralph
    Locker, Anthony S.
    2010 RECORD OF CONFERENCE PAPERS INDUSTRY APPLICATIONS SOCIETY 57TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE PCIC, 2010,
  • [4] Simulation and test of step voltage caused by single-phase grounding fault of 10 kV system earthed with low resistance
    College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
    不详
    不详
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2013, 6 (21-26):
  • [5] A NEW FORMULA FOR CALCULATION OF THE MAXIMUM STEP VOLTAGE IN A SUBSTATION GROUNDING GRID
    CHEN, CX
    XIE, GR
    ELECTRIC POWER SYSTEMS RESEARCH, 1988, 14 (01) : 41 - 49
  • [6] CALCULATION OF GROUNDING RESISTANCE
    CHEN, CX
    ELECTRIC POWER SYSTEMS RESEARCH, 1984, 7 (01) : 29 - 37
  • [7] Voltage Sag Assessment in Distribution System with Neutral Grounding Resistance by Methods of Fault Position and Monte Carlo Simulation
    Posree, Rittipad
    Sirisumrannukul, Somporn
    2021 5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2021), 2021, : 26 - 31
  • [8] High Resistance Neutral Grounding
    Brusso, Barry
    Rifaat, Rasheek
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2012, 18 (01) : 10 - U5
  • [9] Simulation Research on Neutral Grounding Modes of Marine High Voltage Power System
    Wang Haoliang
    Zhang Chunlai
    Li Meng
    Lu Kun
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING 2015 (ICMMCCE 2015), 2015, 39 : 933 - 937
  • [10] Assessment of Voltage Sag and Temporary Overvoltage for Neutral Grounding Resistance in Distribution System
    Rittong, B.
    Sirisumrannukul, S.
    2019 IEEE PES GTD GRAND INTERNATIONAL CONFERENCE AND EXPOSITION ASIA (GTD ASIA), 2019, : 796 - 801