Cargo compartment fire has become the major security threat for cruising aircraft, the depressurization measurement could effectively suppress the cargo compartment fire through the reduction of the air pressure and oxygen concentration. The objective of this work is to study fire behavior characteristics in half confined chamber and high altitude laboratory at identical low atmospheric pressure, and explore the controlling effects of air exhaust condition, oxygen concentration. N-heptane pool fire experiments were conducted separately in Langfang low pressure chamber (altitude 50m) and Kangding airport laboratory (altitude 4290m) at 60 kPa air pressure, both assembled ISO-9705, but their gas supplying condition is different. Mass burning rate, gas composition, flame temperature, and radiant heat flux had been measured as the principal characteristic parameters for analysis. This paper reveals the variation characteristics of the fire behavior under different oxygen concentration but identical low atmospheric pressure. The gas composition of the chamber is controlled by the liquid fire and air intake quantity, the oxygen concentration of the chamber decreases with decreasing gas intake quantity. The mass burning rate increases and the mass burning time decreases with the increase of the oxygen concentration. The higher air intake quantity or the higher oxygen concentration could increase cargo compartment fire radiation intensity, and exacerbate the fire further propagation. However, under the low oxygen concentration condition, the liquid fire still have a higher flame temperature above a certain height. The depressurization measurement could increase the flame height and flame temperature may be caused the cabin fire-resistant liners layer is easier to burn through. The more reasonable adjustment of the cargo compartment air exhaust quantity and air pressure is very meaningful for the comprehensive fire suppression of cruising commercial airplanes.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Kinetics Behavior Research on Oxygen Pressure Acid Leaching of Synthesized Sphalerite with Low Concentration Iron
    Gu, Yan
    Zhang, Ting-an
    Lv, Guo-zhi
    Liu, Yan
    Mu, Wang-zhong
    Dou, Zhi-he
    2011 AASRI CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INDUSTRY APPLICATION (AASRI-AIIA 2011), VOL 4, 2011, : 276 - 282
  • [22] The effect of pressure and oxygen concentration on the combustion of PMMA
    Zarzecki, Mariusz
    Quintiere, James G.
    Lyon, Richard E.
    Rossmann, Tobias
    Diez, Francisco J.
    COMBUSTION AND FLAME, 2013, 160 (08) : 1519 - 1530
  • [23] Kinetics Behavior Research on Oxygen Pressure Acid Leaching of Synthesized Sphalerite with Low Concentration Iron
    Gu, Yan
    Zhang, Ting-an
    Lv, Guo-zhi
    Liu, Yan
    Mu, Wang-zhong
    Dou, Zhi-he
    2011 INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND NEURAL COMPUTING (FSNC 2011), VOL VII, 2011, : 265 - 271
  • [24] Experimental study on liquid fire behavior at different effective ceiling heights in a full-size simulated cargo compartment
    Tao, Zhenxiang
    Yang, Rui
    Li, Cong
    Yao, Yina
    Zhu, Pei
    Zhang, Hui
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 133 (03) : 1617 - 1626
  • [25] CONCENTRATION OF OXYGEN ATOMS IN ATMOSPHERIC PRESSURE AIR GLOW DISCHARGE
    Petrov, A. E.
    Titov, V. A.
    Smirnov, S. A.
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA I KHIMICHESKAYA TEKHNOLOGIYA, 2013, 56 (02): : 80 - +
  • [26] Experimental study on liquid fire behavior at different effective ceiling heights in a full-size simulated cargo compartment
    Zhenxiang Tao
    Rui Yang
    Cong Li
    Yina Yao
    Pei Zhu
    Hui Zhang
    Journal of Thermal Analysis and Calorimetry, 2018, 133 : 1617 - 1626
  • [27] Experimental analysis of low air pressure influences on fire plumes
    Zhou, Zhihui
    Wei, Yao
    Li, Haihang
    Yuen, Richard
    Jian, Wang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 70 : 578 - 585
  • [28] Experimental analysis of low air pressure influences on the fire detection
    Yang, S. L.
    Lu, S.
    Wang, J.
    Liu, C. C.
    Yuen, K. K.
    HYDRAULIC ENGINEERING III, 2015, : 203 - 207
  • [29] Effect of oxygen concentration on pinewood pyrolysis behavior
    Wang, Yun
    Chen, Liang
    Su, Yi
    Wu, Wenguang
    Luo, Yonghao
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2011, 31 (26): : 117 - 123
  • [30] Effect of Obstacles and Horizontal Wind on the Fire Behavior inside Engine Compartment of Motorcoach
    Huang, Dongmei
    Wang, Xinqun
    Guo, Chenning
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS SCIENCE AND ENVIRONMENTAL ENGINEERING, 2016, 52 : 144 - 148