Impact of the Amplatzer Atrial Septal Occluder Device on Left Ventricular Function in Pediatric Patients

被引:10
|
作者
Castaldi, Biagio [1 ]
Santoro, Giuseppe [1 ]
Di Salvo, Giovanni [1 ]
Gaio, Gianpiero [1 ]
Palladino, Maria Teresa [1 ]
D'Aiello, Fabio [1 ]
Iacono, Carola [1 ]
Pacileo, Giuseppe [1 ]
Calabro, Raffaele [1 ]
Russo, Maria Giovanna [1 ]
机构
[1] Univ Naples 2, Ospedali Colli Hosp, I-80033 Cicciano, NA, Italy
关键词
Amplatzer septal occluder; Atrial septal defect; Echocardiography; Strain rate imaging; REGIONAL MYOCARDIAL-FUNCTION; PERCUTANEOUS CLOSURE; TRANSCATHETER CLOSURE; STRAIN-RATE; DEFECT CLOSURE; FOLLOW-UP; SURGICAL CLOSURE; CHILDREN; ADULTS; EXPERIENCE;
D O I
10.1007/s00246-013-0695-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous closure currently is widely considered to be the first-choice therapeutic option in the treatment of ostium secundum atrial septal defect (ASD). The Amplatzer Septal Occluder (ASO) device is the most used prosthesis, although its influence on cardiac function still is under active investigation. This study aimed to evaluate the impact of the ASO device size on left ventricular (LV) function in pediatric patients using the speckle-tracking strain imaging technology. The study enrolled 43 nonobese pediatric patients submitted to percutaneous ASD closure with the Amplatzer Septal Occluder device and grouped them according to the size of the occluding prosthesis into three groups: a small-device group (a parts per thousand currency sign10 mm, group 1), a medium-size-device group (11-16 mm, group 2), and a large-device group (a parts per thousand yen17 mm, group 3). Echocardiographic data were compared among the groups and with the data of an age-, weight-, and gender-matched control group (50 patients). The large-device group showed a significant impairment in the strain rate value of the basal LV segments. In particular, the mean basal circumferential and radial strain rate values were lower than either normal or the values of the small- and medium-device groups. However, only the absolute device diameter reached statistical significance in the multivariate analysis. The large Amplatzer Septal Occluding device significantly impaired LV systolic function, particularly that of juxtaprosthetic segments, as shown in the strain rate analysis.
引用
收藏
页码:1645 / 1651
页数:7
相关论文
共 50 条
  • [21] Transcatheter closure of a posttraumatic ventricular septal defect with an Amplatzer occluder device
    Bauriedel, G
    Redel, DA
    Schmitz, C
    Welz, A
    Schild, HH
    Lüderitz, B
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) : 508 - 512
  • [22] Impact of right ventricular size on ECG after percutaneous closure of atrial septal defect with Amplatzer Septal Occluder
    Di Bernardo, S
    Berger, F
    Fasnacht, M
    Bauersfeld, U
    SWISS MEDICAL WEEKLY, 2005, 135 (43-44) : 647 - 651
  • [23] Closure of secundum atrial septal defects with the Amplatzer septal occluder device: Techniques and problems
    Harper, RW
    Mottram, PM
    McGaw, DJ
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (04) : 508 - 524
  • [24] Dislocation of Amplatzer Septal Occluder Device after Closure of Secundum Atrial Septal Defect
    Piatkowski, Radoslaw
    Kochanowski, Janusz
    Scislo, Piotr
    Kochman, Janusz
    Opolski, Grzegorz
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 1007.e1 - 1007.e2
  • [25] Device closure of atrial septal defects with the Amplatzer septal occluder: Safety and outcome in infants
    Diab, Karim A.
    Cao, Qi-Ling
    Bacha, Emile A.
    Hijazi, Ziyad M.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (04): : 960 - 966
  • [26] Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder
    Divekar, A
    Gaamangwe, T
    Shaikh, N
    Raabe, M
    Ducas, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) : 1213 - 1218
  • [27] Initial human experience with the Amplatzer perimembranous ventricular septal occluder device
    Bass, JL
    Kalra, GS
    Arora, R
    Masura, J
    Gavora, P
    Thanopoulos, BD
    Torres, W
    Sievert, H
    Carminati, M
    Fischer, G
    Ewert, P
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 238 - 245
  • [28] Endocardial occlusion of incompletely surgically ligated left atrial appendage using an Amplatzer septal occluder device
    Aryana, Arash
    Bailey, Sean
    O'Neill, Padraig Gearoid
    d'Avila, Andre
    HEART RHYTHM, 2014, 11 (04) : 735 - 736
  • [29] Transseptal Puncture Through Amplatzer Atrial Septal Occluder for Left Atrial Appendage Closure
    Gloekler, Steffen
    Shakir, Samera
    Meier, Bernhard
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (21) : 2222 - 2223
  • [30] Amplatzer occluder device in adult patients with secundum atrial septal deffect: a single center experience
    Carcagni, A
    Maiello, L
    Milone, F
    Marsico, F
    Zavalloni, D
    Bonemazzi, M
    Presbitero, P
    EUROPEAN HEART JOURNAL, 2002, 23 : 437 - 437