Evaluation of the use of plasma preparation tubes for HIV viral load testing on the COBAS AmpliPrep/COBAS TaqMan HIV-1 version 2.0

被引:3
|
作者
Goedhals, Dominique [1 ]
Scott, Lesley E. [2 ]
Moretti, Serena [1 ,3 ]
Cooper, Mark A. [1 ]
Opperman, Willem J. L. [1 ]
Rossouw, Inez [1 ]
机构
[1] Univ Orange Free State, Natl Hlth Lab Serv, Dept Med Microbiol & Virol, ZA-9300 Bloemfontein, South Africa
[2] Univ Witwatersrand, Sch Pathol, Fac Hlth Sci, Dept Mol Med & Haematol, Johannesburg, South Africa
[3] Univ Orange Free State, Dept Microbial Biochem & Food Biotechnol, ZA-9300 Bloemfontein, South Africa
关键词
HIV viral load; PPT; CAP/CTM HIV-2 v2; IMMUNODEFICIENCY-VIRUS RNA; ANTIRETROVIRAL THERAPY; TYPE-1; RNA; ASSAYS; QUANTIFICATION; COLLECTION; STANDARD; SAMPLES;
D O I
10.1016/j.jviromet.2012.11.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
HIV viral load monitoring forms an essential part of the management of patients receiving antiretroviral therapy, but transport of samples without loss of RNA integrity may be problematic in resource limited settings. The use of plasma preparation tubes (PPT) which can be centrifuged to separate cellular components before transport may provide a simple and cost-effective alternative to standard EDTA samples. We investigated whether PPT generated reliable results using the COBAS (R) AmpliPrep/COBAS (R) TaqMan (R) HIV-1 test version 2.0 (CAP/CTM HIV-1 v2.0). The mean difference between EDTA and PPT prepared samples (n = 261) was acceptable (log 0.04 copies/ml, percentage similarity CV 3.53%). PPT can be used for viral load testing on the CAP/CTM HIV-1 v2.0. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:248 / 250
页数:3
相关论文
共 50 条
  • [31] Comparison of the cobas Human Immunodeficiency Virus 1 (HIV-1) Test Using the cobas 4800 System With COBAS AmpliPrep/COBAS TaqMan HIV-1 Test and Abbott RealTime HIV-1 Assay and Performance Evaluation of cobas HIV-1
    Shin, Kyung-Hwa
    Lee, Hyun-Ji
    Lee, Jin Hyeon
    Chang, Chulhun L.
    Kim, Hyung-Hoi
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 152 (05) : 558 - 562
  • [32] Total HIV-1 DNA detection and quantification in peripheral blood by COBAS®AmpliPrep/COBAS® TaqMan® HIV-1 Test, v2.0
    Surdo, Matteo
    Bertoli, Ada
    Colucci, Giuseppe
    Sarmati, Loredana
    Andreoni, Massimo
    Perno, Carlo Federico
    Ceccherini-Silberstein, Francesca
    Ciotti, Marco
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (02) : E57 - E59
  • [33] Performance evaluation of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit: Comparison with the Roche COBAS® AmpliPrep/COBAS TaqMan® HIV-1 Test Ver.2.0 for quantification of HIV-1 viral load in Indonesia
    Kosasih, Agus Susanto
    Sugiarto, Christine
    Hayuanta, Hubertus Hosti
    Juhaendi, Runingsih
    Setiawan, Lyana
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2018, 36 (02): : 120 - 125
  • [34] Workflow and cost comparison of COBAS AmpliPrep/COBAS TaqMan HIV-1 test and Abbott ReaITime HIV-1 assay
    Sloma, C. R.
    Gerads, T. M.
    Germer, J. J.
    Mitchell, P. S.
    Yao, J. D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 674 - 675
  • [35] Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China
    Xu, Sihong
    Song, Aijing
    Nie, Jianhui
    Li, Xiuhua
    Meng, Shufang
    Zhang, Chuntao
    Wang, Youchun
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (01) : 33 - 37
  • [36] Comparison of the QIAGEN artus HIV-1 QS-RGQ test with the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v2.0
    Wall, G. R.
    Perinpanathan, D.
    Clark, D. A.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 55 (01) : 62 - 66
  • [37] Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples
    Schonning, Kristian
    Johansen, Kim
    Landt, Bodil
    Benfield, Thomas
    Westh, Henrik
    JOURNAL OF CLINICAL VIROLOGY, 2017, 92 : 14 - 19
  • [38] Verification of the Roche COBAS HIV-1, HCV and HBV Tests on the COBAS 6800 System and Correlation to the COBAS Ampliprep/COBAS TaqMan System
    Sabato, M.
    Barto, L.
    Margaritini, C.
    Earles, S.
    Anaya-Bergman, C.
    Sene, M.
    Ferreira-Gonzalez, A.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (06): : 1164 - 1164
  • [39] Potential Influence of More-Sensitive HIV-1 Load Detection by the new Roche Cobas AmpliPrep/Cobas TaqMan Version 2.0 Assay on Clinical Management of HIV-Positive Pregnant Women
    de Boer, M. G. J.
    Wessels, E.
    Claas, E. C. J.
    Kroon, F. P.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) : 4301 - 4302
  • [40] Multicenter evaluation of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system for the quantification of HIV-1 plasma viral load
    Adams, Phillip
    Vancutsem, Ellen
    Nicolaizeau, Cyrielle
    Servais, Jean-Yves
    Pierard, Denis
    Francois, Jean-Hugues
    Schneider, Tanja
    Paxinos, Ellen E.
    Marins, Ed G.
    Canchola, Jesse A.
    Seguin-Devaux, Carole
    JOURNAL OF CLINICAL VIROLOGY, 2019, 114 : 43 - 49