Automated serial ECG comparison improves computerized interpretation of 12-lead ECG

被引:5
|
作者
Gregg, Richard E. [1 ]
Deluca, Daniel C. [2 ]
Chien, Cheng-hao Simon [1 ]
Helfenbein, Eric D. [1 ]
Ariet, Mario [2 ]
机构
[1] Philips Healthcare, Adv Algorithm Res Ctr, Andover, MA 01810 USA
[2] Univ Florida, Dept Med, Gainesville, FL USA
关键词
12-lead ECG analysis; Automated serial ECG comparison; PROGRAM;
D O I
10.1016/j.jelectrocard.2012.07.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Interpretation of a patient's 12-lead ECG frequently involves comparison to a previously recorded ECG. Automated serial ECG comparison can be helpful not only to note significant ECG changes but also to improve the single-ECG interpretation. Corrections from the previous ECG are carried forward by the serial comparison algorithm when measurements do not change significantly. Methods: A sample of patients from three hospitals was collected with two or more 12-lead ECGs from each patient. There were 233 serial comparisons from 143 patients. 41% of patients had two ECGs and 59% of patients had more than two ECGs. ECGs were taken from a difficult population as measured by ECG abnormalities, 197/233 abnormal, 11/233 borderline, 14/233 otherwise-normal and 11/233 normal. ECGs were processed with the Philips DXL algorithm and then in time order for each patient with the Philips serial comparison algorithm. To measure accuracy of interpretation and serial change, an expert cardiologist corrected the ECGs in stages. The first ECG was corrected and used as the reference for the second ECG. The second ECG was then corrected and used as the reference for the third ECG and so on. At each stage, the serial comparison algorithm compared an unedited ECG to an earlier edited ECG. Interpretation accuracy was measured by comparing the algorithm to the cardiologist on a statement by statement basis. The effect of serial comparison was measured by the sum of interpretive statement mismatches between the algorithm and cardiologist. Statement mismatches were measured in two ways, (1) exact match and (2) match within the same diagnostic category. Results: The cardiologist used 910 statements over 233 ECGs for an average number of 3.9 statements per ECG and a mode of 4 statements. When automated serial comparison was used, the total number of exact statement mismatches decreased by 29% and the total same-category statement mismatches decreased by 47%. Conclusion: Automated serial comparison improves interpretation accuracy in addition to its main role of noting differences between ECGs. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:561 / 565
页数:5
相关论文
共 50 条
  • [31] An intelligent framework for the classification of the 12-lead ECG
    Nugent, CD
    Webb, JAC
    Black, ND
    Wright, GTH
    McIntyre, M
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 1999, 16 (03) : 205 - 222
  • [32] The 12-lead ECG in patients with Mahaim fibers
    Sternick, EB
    Gerken, LM
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2006, 11 (01) : 63 - 83
  • [33] The 12-lead ECG: a continuous reference for the cardiologist
    Boriani, Giuseppe
    Vitolo, Marco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (07) : 459 - 463
  • [34] Prehospital 12-lead ECG diagnostic programs
    Urban, MJ
    Edmondson, DA
    Aufderheide, TP
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2002, 20 (04) : 825 - +
  • [35] A Portable 12-Lead ECG Acquisition System
    Sun, Cheng
    Liao, Jingsheng
    Wang, Gang
    Li, Baopu
    Meng, Max Q-H
    2013 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2013, : 368 - 373
  • [36] Prehospital 12-lead ECG: Efficacy or effectiveness?
    Swor, Robert
    Hegerberg, Stacey
    McHugh-McNally, Ann
    Goldstein, Mark
    McEachin, Christine C.
    PREHOSPITAL EMERGENCY CARE, 2006, 10 (03) : 374 - 377
  • [37] Shark Fin Sign on a 12-Lead ECG
    Macherey-Meyer, Sascha
    Terporten, Johannes
    Adler, Christoph
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2024, 121 (20):
  • [38] A New 12-Lead ECG Prognostic Score
    Soofi, Muhammad
    Jain, Nikhil A.
    Myers, Jonathan
    Froelicher, V. F.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (06) : 554 - 560
  • [39] A novel method for 12-lead ECG reconstruction
    EPMoghaddam, Dorsa
    Banta, Anton
    Post, Allison
    Razavi, Mehdi
    Aazhang, Behnaam
    FIFTY-SEVENTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, IEEECONF, 2023, : 1054 - 1058
  • [40] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Wang, Lu-di
    Zhou, Wei
    Xing, Ying
    Liu, Na
    Movahedipour, Mahmood
    Zhou, Xiao-guang
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (03) : 405 - 413