Impedance pneumography: Noise as signal in impedance cardiography

被引:130
|
作者
Ernst, JM [1 ]
Litvack, DA [1 ]
Lozano, DL [1 ]
Cacioppo, JT [1 ]
Berntson, GG [1 ]
机构
[1] Ohio State Univ, Dept Psychol, Columbus, OH 43210 USA
关键词
impedance pneumography; respiration; respirometry; tetrapolar electrodes;
D O I
10.1017/S0048577299981003
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of "noise" in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band electrodes. We recorded the change in impedance (Delta Z), the first derivative of the change in impedance (dZ/dt), output from a strain-gauge respirometer, and criterion spirometry from eight healthy adults during rest, paced breathing, abdominal breathing, thoracic breathing, and a mental arithmetic task. Transfer function analyses revealed that a Delta Z(d) Signal (derived by integration of the dZ/dt signal) provided the best estimate of the criterion spirometric measure for all parameters (coherence, phase, and gain), accounting for almost 90% of the variance in respiratory waveform morphology. The results document thr potential utility of impedance pneumography, as derived from standard impedance cardiography signals.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [31] THE VALIDITY OF IMPEDANCE CARDIOGRAPHY
    BUELL, JC
    MCKINNEY, ME
    BECK, B
    MEYERS, D
    ELIOT, RS
    PSYCHOPHYSIOLOGY, 1983, 20 (04) : 420 - 420
  • [32] PROBLEMS OF IMPEDANCE CARDIOGRAPHY
    SAKAMOTO, K
    MUTO, K
    KANAI, H
    IIZUKA, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (06) : 697 - 709
  • [33] THORACIC IMPEDANCE CARDIOGRAPHY
    SPODICK, DH
    AMERICAN HEART JOURNAL, 1982, 104 (06) : 1392 - 1392
  • [34] A REVIEW OF IMPEDANCE CARDIOGRAPHY
    JENSEN, L
    YAKIMETS, J
    TEO, KK
    HEART & LUNG, 1995, 24 (03): : 183 - 193
  • [35] Evaluation of Respiratory Signal Record Based on Impedance Pneumography and Textile Electrodes
    Ruben Dell'Aquila, Carlos
    Eduardo Canadas, Gabriel
    Laciar, Eric
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1502 - 1509
  • [36] SIGNAL-TO-MOTION ARTIFACT RATIO VERSUS FREQUENCY FOR IMPEDANCE PNEUMOGRAPHY
    ROSELL, J
    WEBSTER, JG
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (03) : 321 - 323
  • [37] Impedance cardiography signal denoising using discrete wavelet transform
    Souhir Chabchoub
    Sofienne Mansouri
    Ridha Ben Salah
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 655 - 663
  • [38] Impedance cardiography signal denoising using discrete wavelet transform
    Chabchoub, Souhir
    Mansouri, Sofienne
    Ben Salah, Ridha
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (03) : 655 - 663
  • [39] CANCELLING THE CARDIOGENIC ARTIFACT IN IMPEDANCE PNEUMOGRAPHY
    SAHAKIAN, AV
    KUO, KH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (10) : 893 - 893
  • [40] Recycling cardiogenic artifacts in impedance pneumography
    Lu, Yao
    Wu, Hau-tieng
    Malik, John
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 51 : 162 - 170