Comparison of breath-hold 2D phase-contrast with non breath-hold cine phase-contrast MRA in the assessment of azygos venous blood flow in portal hypertension

被引:20
|
作者
Ng, WH [1 ]
Chan, YL
Sung, JY
Lee, YT
Lee, SF
Chung, SSC
机构
[1] Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Shatin, Hong Kong, Peoples R China
[2] Prince Wales Hosp, Dept Med & Therapeut, Shatin, Hong Kong, Peoples R China
[3] Prince Wales Hosp, Dept Surg, Shatin, Hong Kong, Peoples R China
关键词
MRA; azygos venous flow; cirrhosis varices;
D O I
10.1007/s10334-003-0026-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Azygos venous blood flow as an index of blood flow through the gastroesophageal collaterals and varices is of value in the prediction of gastrointestinal bleeding. Measurement of azygos venous blood flow has been achieved by non breath-hold (NBH) cine phase-contrast magnetic resonance imaging. The objective of this study was to compare the faster breath-hold (BH) phase-contrast technique with the standard (NBH) cine phase-contrast technique in the measurement of azygos blood flow. Thirty-two cirrhotic patients with esophageal varices were examined by magnetic resonance imaging using a BH technique and a NBH cine phase-contrast technique to measure the flow velocity, flow volume and calibre of the azygos vein at the mid-right atrial level. The flow values were obtained on the velocity image of the phase-contrast study. Values obtained from the two methods were evaluated statistically for the strength and significance of correlation by the Pearson test. Measurement by the BH method performed at full-inspiration as well as end-expiration was also obtained in 15 healthy volunteers. The breath-hold phase-contrast method has significant but weak correlation with non BH cine phase-contrast method in the measurement of azygos venous blood flow volume (r = 0.55 p<0.01) and flow velocity (r = 0.43, p = 0.01). However, the calibre of the azygos vein gave a strong correlation in these two methods (0.82). In the subgroup of patients whose azygos blood flow velocity was greater than 7.4 cm/s, the correlation of azygos blood flow volume is strong (r = 0.80, p<0.01). The azygos vein calibre remains highly correlated between the BH and NBH method, in both high flow velocity (r = 0.73) and low flow velocity (r = 0.83) groups. Breath-hold sequence leads to higher values for flow velocity and flow volume in the cirrhotic patients and also the control group. In patients with portal hypertension, BH 2D phase-contrast (PC) magnetic resonance angiography (MRA) could give a comparable estimation of the calibre of the azygos vein as the NBH 2D cine PC MRA but not for azygos flow volume. In patients with high azygos flow velocity, the strong correlation in flow volume between the BH and NBH method suggests that the BH method may be a time-saving alternative to the NBH method.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [41] Phase-contrast MRI volume flow – a comparison of breath held and navigator based acquisitions
    Charlotta Andersson
    Johan Kihlberg
    Tino Ebbers
    Lena Lindström
    Carl-Johan Carlhäll
    Jan E. Engvall
    BMC Medical Imaging, 16
  • [42] MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP
    D. J. Lomas
    P. W. P. Bearcroft
    A. E. Gimson
    European Radiology, 1999, 9 : 1411 - 1417
  • [43] Measuring blood flow by nontriggered 2D phase-contrast MR angiography
    Bakker, CJG
    Hartkamp, MJ
    Mali, WPTM
    MAGNETIC RESONANCE IMAGING, 1996, 14 (06) : 609 - 614
  • [44] 4D and Multi-phase Breath-hold CT Imaging with Synchronized Intravenous Contrast Injection for Liver Tumor Delineation
    Suh, Yelin
    Beddar, Sam
    Wen, Zhifei
    Das, Prajnan
    Delclos, Marc E.
    Krishnan, Sunil
    Minsky, Bruce
    Crane, Christopher
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [45] VOLUMETRIC FLOW-RATES IN THE PORTAL VENOUS SYSTEM - MEASUREMENT WITH CINE PHASE-CONTRAST MR IMAGING
    BURKART, DJ
    JOHNSON, CD
    MORTON, MJ
    WOLF, RL
    EHMAN, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1113 - 1118
  • [46] Investigating the Limitations of Single Breath-Hold Renal Artery Blood Flow Measurements Using Spiral Phase Contrast MR With R-R Interval Averaging
    Steeden, Jennifer A.
    Muthurangu, Vivek
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 1143 - 1149
  • [47] FLOW MEASUREMENTS - CINE VERSUS 2D VERSUS FASTCARD PHASE-CONTRAST MR-IMAGING
    HARA, AK
    BURKART, DJ
    FELMLEE, JP
    JOHNSON, CD
    EHMAN, RL
    RADIOLOGY, 1995, 197 : 248 - 248
  • [48] MR FLOW MEASUREMENT WITH 2D PHASE-CONTRAST IMAGING - ASSESSMENT OF IMAGING PARAMETERS
    DARKAZANLI, A
    AKATA, S
    GMITRO, AF
    UNGER, EC
    YOSHINO, MT
    RADIOLOGY, 1992, 185 : 272 - 273
  • [49] The effects of flip angle and gadolinium contrast agent on single breath-hold compressed sensing cardiac magnetic resonance cine for biventricular global strain assessment
    Wang, Fuyan
    Pu, Cailing
    Ma, Siying
    Zhou, Junjie
    Jiang, Yangyang
    Yu, Feidan
    Zhang, Shuheng
    Wu, Yan
    Zhang, Lingjie
    He, Chengbin
    Hu, Hongjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [50] Single breath-hold non-contrast thoracic mra using highly-accelerated parallel imaging with a 32-element coil array
    Jian Xu
    Kellyanne Mcgorty
    Ruth Lim
    Mary Bruno
    Monvadi Srichai
    Daniel Kim
    Daniel K Sodickson