Gradient Calibration for the RCBHT Cantilever Snap Verification System.

被引:0
|
作者
Rojas, J. [1 ]
Harada, K. [1 ]
Onda, H. [1 ]
Yamanobe, N. [1 ]
Yoshida, E. [1 ]
Nagata, K. [1 ]
Kawai, Y. [1 ]
机构
[1] AIST, Intelligent Sys Res Inst, Tsukuba, Ibaraki 3058568, Japan
关键词
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
In this work a gradient calibration method was presented as part of the Relative-Change-Based-Hierarchical Taxonomy (RCBHT) cantilever-snap verification system and the Pivot Approach control strategy for the automation of cantilever-snaps. As part of a relative-change based force signal interpretation scheme, an effective gradient calibration process is needed to increase the RCBHT's system robustness. Prior to this work, all gradient classification schemes were derived on an intuitive trial and error basis. Statistical measures were used to derive contact and constant gradient thresholds in contextually sensitive ways. The method requires training assemblies to identify a minimum contact gradient which serves as a marker for all other gradient thresholds. Experimental procedures verified that our calibration method was effective. Assemblies with supervised successful outcomes were used in experimentation. The RCBHT assessed out assemblies as successful using the calibration method. Even two snaps that where classified falsely as unsuccessful when using a previously non-calibrated version of the RCBHT.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Geometric Calibration and Verification of a GammaPod Breast SBRT System
    Yu, C.
    Niu, Y.
    Mutaf, Y.
    Maton, P.
    Hoban, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3435 - 3435
  • [32] PET system activity concentration calibration and verification regimen
    Ruter, Royce
    Kemp, Brad
    Peller, Patrick
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [33] The uBVI photometric system.: I.: Motivation, implementation, and calibration
    Bond, HE
    ASTRONOMICAL JOURNAL, 2005, 129 (06): : 2914 - 2923
  • [34] Verification and calibration of natural gas flow measuring system
    Lei, Li
    Zhao, Pujun
    Liu, Wei
    Tianranqi Gongye/Natural Gas Industry, 2002, 22 (04): : 73 - 75
  • [35] Calibration of continuous flow-through mucosal perfusion system.
    VanderBijl, P
    Squier, CA
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1208 - 1208
  • [36] SULFUR DIOXIDE DEPOSITION VELOCITY BY A CONCENTRATION GRADIENT MEASUREMENT SYSTEM.
    Davis, C.S.
    Wright, R.G.
    1600, (90):
  • [37] Gradient Nonlinearity Calibration and Correction for Head-Only Asymmetric Gradient System
    Tao, S.
    Trzasko, J.
    Shu, Y.
    Weavers, P.
    Huston, J., III
    Lee, S.
    Mathieu, J.
    Foo, T.
    Bernstein, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3737 - 3737
  • [38] Linear calibration method of magnetic gradient tensor system
    Yin Gang
    Zhang Yingtang
    Fan Hongbo
    Zhang Guang
    Ren Guoquan
    MEASUREMENT, 2014, 56 : 8 - 18
  • [39] Nonlinear calibration method of magnetic gradient tensor system
    Yin G.
    Zhang L.
    Xie Y.
    Wei Z.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2018, 39 (04): : 35 - 43
  • [40] APPROACH TO HIERARCHICAL AND MODULAR PROGRAM CONSTRUCTION AND VERIFICATION - THE iota PROGRAMMING SYSTEM.
    Nakajima, Reiji