Low-pressure treatment control of glaucoma using an electromagnetic valve in actuator with a piezoresistive pressure sensor

被引:0
|
作者
Bae, B [1 ]
Park, K [1 ]
Shannon, MA [1 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Urbana, IL 61801 USA
关键词
treatment of glaucoma; valve actuator; pressure sensor;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper concerns the control of intraocular pressure (IOP, eye pressure) for the treatment of glaucoma within a hundred pascal out of a total of a few thousand pascal by using an electromagnetic valve actuator and a pressure sensor. The proposed valve actuator is electromagnetically driven to change the area of the outlet by moving a membrane vertically, which is optimally designed to give the maximum pressure sensitivity over the applied voltage. The pressure sensor is piezoresistive type whose geometric parameters such as length and number of turns of the piezoresistor are optimally designed to give the maximum signal to noise ratio, which becomes critical in this low-pressure regime, in the case of constant voltage excitation and measurement. It is experimentally demonstrated that the pressure can be controlled below a 100 Pa resolution by using the proposed valve actuator and the pressure sensor.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 50 条
  • [21] Visual field asymmetry is unrelated to intraocular pressure asymmetry in the low-pressure glaucoma treatment study
    Greenfield, DS
    Liebmann, JM
    Ritch, R
    Krupin, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [22] Baseline intraocular pressure, visual function, and disc hemorrhage in the low-pressure glaucoma treatment study
    Liebmann, JM
    Greenfield, DS
    Piltz-Seymour, J
    Ritch, R
    Krupin, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [23] Pressure control in a low-pressure casting furnace
    Belforte, G
    Carello, M
    Ivanov, A
    PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON FLUID POWER TRANSMISSION AND CONTROL, 2005, : 345 - 348
  • [24] EXTRAOCULAR CIRCULATORY DISORDERS AND LOW-PRESSURE GLAUCOMA
    PILLUNAT, LE
    STODTMEISTER, R
    CHRIST, T
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (03) : 230 - 231
  • [25] A Wireless and Passive Low-Pressure Sensor
    Nicolay, Pascal
    Lenzhofer, Martin
    SENSORS, 2014, 14 (02) : 3065 - 3076
  • [26] Sensor tracks low-pressure carburizing
    Jacquet, P
    Bernard, G
    Lambertin, M
    ADVANCED MATERIALS & PROCESSES, 2000, : H19 - H21
  • [27] LOW-PRESSURE SENSING AND CONTROL
    COOPER, FG
    INTECH, 1992, 39 (09) : 38 - 40
  • [28] Nanocomposite-Based Microstructured Piezoresistive Pressure Sensors for Low-Pressure Measurement Range
    Mitrakos, Vasileios
    Hands, Philip J. W.
    Cummins, Gerard
    Macintyre, Lisa
    Denison, Fiona C.
    Flynn, David
    Desmulliez, Marc P. Y.
    MICROMACHINES, 2018, 9 (02):
  • [29] Differential pressure sensor using a piezoresistive cantilever
    Takahashi, Hidetoshi
    Nguyen Minh Dung
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (05)
  • [30] Correction of a piezoresistive pressure sensor using a microcontroller
    Saponjic, D.
    Zigic, A.