Low-pressure treatment control of glaucoma using an electromagnetic valve in actuator with a piezoresistive pressure sensor

被引:0
|
作者
Bae, B [1 ]
Park, K [1 ]
Shannon, MA [1 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Urbana, IL 61801 USA
关键词
treatment of glaucoma; valve actuator; pressure sensor;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper concerns the control of intraocular pressure (IOP, eye pressure) for the treatment of glaucoma within a hundred pascal out of a total of a few thousand pascal by using an electromagnetic valve actuator and a pressure sensor. The proposed valve actuator is electromagnetically driven to change the area of the outlet by moving a membrane vertically, which is optimally designed to give the maximum pressure sensitivity over the applied voltage. The pressure sensor is piezoresistive type whose geometric parameters such as length and number of turns of the piezoresistor are optimally designed to give the maximum signal to noise ratio, which becomes critical in this low-pressure regime, in the case of constant voltage excitation and measurement. It is experimentally demonstrated that the pressure can be controlled below a 100 Pa resolution by using the proposed valve actuator and the pressure sensor.
引用
收藏
页码:126 / 129
页数:4
相关论文
共 50 条
  • [1] The warm-up and offset stability of a low-pressure piezoresistive ceramic pressure sensor
    Zarnik, Marina Santo
    Belavic, Darko
    Macek, Srecko
    SENSORS AND ACTUATORS A-PHYSICAL, 2010, 158 (02) : 198 - 206
  • [2] The Low-Pressure Glaucoma Treatment Study (LoGTS)
    Krupin, T
    Liebmann, JM
    Greenfield, DS
    Rosenberg, LF
    Ritch, R
    Yang, JW
    OPHTHALMOLOGY, 2005, 112 (03) : 376 - 385
  • [3] A SQUARE-DIAPHRAGM PIEZORESISTIVE PRESSURE SENSOR WITH A RECTANGULAR CENTRAL BOSS FOR LOW-PRESSURE RANGES
    SANDMAIER, H
    KUHL, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (10) : 1754 - 1759
  • [4] Mechanical Structural Design of a Piezoresistive Pressure Sensor for Low-Pressure Measurement: A Computational Analysis by Increases in the Sensor Sensitivity
    Anh Vang Tran
    Zhang, Xianmin
    Zhu, Benliang
    SENSORS, 2018, 18 (07)
  • [5] Infographic: Low-Pressure Glaucoma Treatment Study (LoGTS)
    Yen N. Mau
    Christin Henein
    Rashmi G. Mathew
    Eye, 2021, 35 : 2670 - 2670
  • [6] IInfographic: Low-Pressure Glaucoma Treatment Study (LoGTS)
    Mau, Yen N.
    Henein, Christin
    Mathew, Rashmi G.
    EYE, 2021, 35 (10) : 2670 - 2670
  • [7] Visual field and intraocular pressure asymmetry in the low-pressure glaucoma treatment study
    Greenfield, David S.
    Liebmann, Jeffrey M.
    Ritch, Robert
    Krupin, Theodore
    OPHTHALMOLOGY, 2007, 114 (03) : 460 - 465
  • [8] Development and characterization of a novel nanocomposite-polymer based piezoresistive pressure sensor for low-pressure application
    Chauhan, Shivanku
    Ranjan, Prabhat
    Ansari, Mohd. Zahid
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (09) : 3955 - 3963
  • [9] PIEZORESISTIVE LOW-PRESSURE SENSOR WITH HIGH-SENSITIVITY AND HIGH-ACCURACY
    SANDMAIER, H
    KUHL, K
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 21 (1-3) : 142 - 145
  • [10] Low-pressure measurement using an ultrasonic sensor
    Ishikawa, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (4A): : 2173 - 2174