Repair of stent graft-induced retrograde type A aortic dissection using the E-vita open prosthesis

被引:26
|
作者
Gorlitzer, Michael [1 ]
Weiss, Gabriel [1 ]
Moidl, Reinhard [1 ]
Folkmann, Sandra [1 ]
Waldenberger, Ferdinand [1 ]
Czerny, Martin [2 ]
Grabenwoeger, Martin [1 ]
机构
[1] Hosp Hietzing, Dept Cardiovasc Surg, A-1130 Vienna, Austria
[2] Univ Hosp Bern, Dept Cardiovasc Surg, CH-3010 Bern, Switzerland
关键词
Retrograde type A dissection; Endovascular aortic repair; Type B dissection; DESCENDING THORACIC AORTA; B DISSECTION; ENDOVASCULAR REPAIR; PLACEMENT; EXTENSION; EXPERIENCE; SURGERY;
D O I
10.1093/ejcts/ezs041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stent graft-induced retrograde type A dissection is a life-threatening complication after endovascular treatment of acute aortic type B dissections. From August 2005 to February 2011, retrograde aortic dissection occurred in 4 of 29 patients (13.8%) undergoing thoracic endovascular aortic repair (TEVAR) for acute complicated aortic type B dissection. Three patients underwent emergent surgical conversion immediately after TEVAR. The operative strategy was a combined surgical and endovascular approach (frozen elephant trunk technique) using a specially designed hybrid prosthesis (Jotec E-vita open). All operations were performed under moderate hypothermia (25-28 degrees C) and selective bilateral antegrade cerebral perfusion. The mean duration of circulatory arrest was 56 +/- 7 min. Operative data and the outcome of surgery were analysed retrospectively. Data were analysed retrospectively in the limited number of patients. All patients survived the surgical procedure. No stroke, paraplegia, renal failure or other major complications occurred. Postoperative CT scans revealed perigraft thrombus formation and stable aortic dimensions in all patients after 6 months. In one patient, the retrograde dissection remained primarily undetected and untreated. The patient died suddenly, with no clinical signs, within 7 days after stent graft implantation. Autopsy revealed cardiac tamponade due to retrograde type A aortic dissection. Retrograde aortic dissection type A is a serious complication of thoracic endovascular repair of acute aortic type B dissection. Despite the small number of patients investigated in this study, the frozen elephant trunk technique appears to be a feasible bail-out strategy for the treatment of these acute aortic events.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 50 条
  • [31] Initial Experience With Abdominal Aneurysm Repair Using the E-vita Abdominal Stent-Graft: A Single-Center Study
    Zipfel, Burkhart
    Buz, Semih
    Duesterhoeft, Volker
    Hetzer, Roland
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (05) : 577 - 589
  • [32] Open Surgery with Frozen Elephant Trunk for the Treatment of Proximal Stent Graft-Induced New Entry in Type B Aortic Dissection: A Case Report
    Ren, Changwei
    Xu, Shangdong
    Lai, Yongqiang
    Zheng, Jun
    Sun, Lizhong
    ANNALS OF VASCULAR SURGERY, 2015, 29 (06) : 1316.e21 - 1316.e24
  • [33] Implantation sequence modification averts distal stent graft-induced new entry after endovascular repair of Stanford type B aortic dissection
    Chen, I-Ming
    Huang, Chun-Yang
    Weng, Shih-Hsien
    Lin, Ping-Yi
    Chen, Po-Lin
    Chen, Wei-Yuan
    Shih, Chun-Che
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (02) : 281 - 288
  • [34] Facilitated surgical strategy in total arch replacement and descending aorta stent grafting with the E-vita open hybrid prosthesis
    Jakob, Heinz
    ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (05) : 663 - 664
  • [35] Overall Essen's experience with the E-vita open hybrid stent graft system and evolution of the surgical technique
    Tsagakis, Konstantinos
    Dohle, Daniel
    Benedik, Jaroslav
    Lieder, Helmut
    Jakob, Heinz
    ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (05) : 612 - 620
  • [36] Retrograde Type A Aortic Dissection After Endovascular Stent Graft Placement for Treatment of Type B Dissection
    Dong, Zhi Hui
    Fu, Wei Guo
    Wang, Yu Qi
    Guo, Da Qiao
    Xu, Xin
    Ji, Yuan
    Chen, Bin
    Jiang, Jun Hao
    Yang, Jue
    Shi, Zhen Yu
    Zhu, Ting
    Shi, Yun
    CIRCULATION, 2009, 119 (05) : 735 - U133
  • [37] In Situ Laser Stent Graft Fenestration for Repairing Retrograde Type A Dissection During Thoracic Endovascular Aortic Repair
    Qin, Jinbao
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E110 - E110
  • [38] Retrograde extension of type B dissection after endovascular stent graft repair
    Urbanski, PP
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (04) : 767 - 768
  • [39] Distal Stent Graft-Induced New Entry: An Emerging Complication of Endovascular Treatment in Aortic Dissection
    Pantaleo, Antonio
    Jafrancesco, Giuliano
    Buia, Francesco
    Leone, Alessandro
    Lovato, Luigi
    Russo, Vincenzo
    Di Marco, Luca
    Di Bartolomeo, Roberto
    Pacini, Davide
    ANNALS OF THORACIC SURGERY, 2016, 102 (02): : 527 - 533
  • [40] Distal Stent Graft-Induced New Entry After TEVAR of Type B Aortic Dissection: Experience in 15 Years
    Li, Qing
    Ma, Wei-Guo
    Zheng, Jun
    Xu, Shang-Dong
    Chen, Yu
    Liu, Yong-Min
    Zhu, Jun-Ming
    Huang, Lian-Jun
    Sun, Li-Zhong
    ANNALS OF THORACIC SURGERY, 2019, 107 (03): : 718 - 724