An on-line multi-parameter analyzing optical biosensor for real-time and non-invasive monitoring of plant stress responses in vivo

被引:3
|
作者
Zhang LingRui
Xing Da [1 ]
Wen Feng
机构
[1] S China Normal Univ, MOE Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
来源
CHINESE SCIENCE BULLETIN | 2009年 / 54卷 / 21期
基金
中国国家自然科学基金;
关键词
heat stress; heat shock protein 101; reactive oxygen species; delayed fluorescence; net photosynthesis rate; PHOTOSYNTHETIC ELECTRON-TRANSPORT; DELAYED FLUORESCENCE; QUANTUM YIELD; HEAT-SHOCK; OXYGEN; TEMPERATURE;
D O I
10.1007/s11434-009-0157-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Photosynthetic dysfunction and reactive oxygen species (ROS) production are the common features of plant stress responses. Based on quantitative measurement of ROS production and delayed fluorescence (DF) emission, which is an excellent marker for evaluating photosynthesis, an on-line multiparameter analyzing optical biosensor for detecting plant stress responses was developed. Performances of the proposed biosensor were tested in the wild type (WT) Arabidopsis and heat shock protein (Hsp) 101 T-DNA knockout mutant (hsp101) plants with different thermotolerance. Results demonstrated that DF intensity correlates with net photosynthesis rate (Pn) in response to elevated temperature in both the WT Arabidopsis and hsp101 mutant plants. The light response characteristics and the recovery dynamics of the DF intensity were also in line with those of Pin in both the WT Arabidopsis and hsp101 mutant plants after heat stress (HS, 40 degrees C for 30 min), respectively. In all experiments discussed above, the hsp101 plant showed the worse photosynthetic performance than the WT plant. Moreover, after HS, more ROS production in the hsp101 mutant than in WT Arabidopsis, which was found to be mainly localized at chloroplasts, could be directly detected by using the proposed biosensor. In addition, the hsp101 mutant showed severer chloroplasts alterations than the WT plant within the first 1 h of recovery following HS. Nevertheless, pre-infiltration with catalase (CAT) reduced ROS production and prevented the declines of the DF intensity. Therefore, HS-caused declines of photosynthetic performance might be due to oxidative damage to photosynthetic organelle. To sum up, we conclude that Hsp101 plays an important role in preventing oxidative stress, and the proposed optical biosensor might be a powerful tool to determine plant stress responses and identify plant resistant difference.
引用
收藏
页码:4009 / 4016
页数:8
相关论文
共 50 条
  • [41] Monitoring plasmid DNA induction strategies using multi-parameter flow cytometry and real-time PCR
    Silva, F.
    Lourenco, O.
    Maia, C.
    Queiroz, J. A.
    Domingues, F. C.
    JOURNAL OF BIOTECHNOLOGY, 2010, 150 : S530 - S531
  • [42] Non-Invasive and Real-Time Monitoring of the Breast Cancer Metastasis Degree via Metabolomics
    Zhu, Wanfang
    Qian, Wenxin
    Liao, Wenting
    Huang, Xiaoxian
    Xu, Jiawen
    Qu, Wei
    Xue, Jingwei
    Feng, Feng
    Liu, Wenyuan
    Liu, Fulei
    Han, Lingfei
    CANCERS, 2022, 14 (22)
  • [43] Nanobiosensing Platforms for Real-Time and Non-Invasive Monitoring of Stem Cell Pluripotency and Differentiation
    Suhito, Intan Rosalina
    Angeline, Novi
    Choo, Sung-Sik
    Woo, Ho Young
    Paik, Taejong
    Lee, Taek
    Kim, Tae-Hyung
    SENSORS, 2018, 18 (09)
  • [44] Non-invasive Vital Signs Monitoring System with Real-Time Caution and Emergency Alerts
    Cabanillas-Carbonell, Michael A.
    Zapata-Paulini, Joselyn E.
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [45] Non-invasive real-time genomic monitoring of the critically endangered kākāpō
    Urban, Lara
    Miller, Allison K.
    Eason, Daryl
    Vercoe, Deidre
    Shaffer, Megan
    Wilkinson, Shaun P.
    Jeunen, Gert-Jan
    Gemmell, Neil J.
    Digby, Andrew
    ELIFE, 2023, 12
  • [46] Non-invasive real-time monitoring of cell concentration and viability using Doppler ultrasound
    Akbari, Samin
    Anderson, Phillip
    Zang, Han
    Ganjian, Amin
    Balke, Robert
    Kwon, Taehong
    Pollard, David
    SLAS TECHNOLOGY, 2022, 27 (06): : 368 - 375
  • [47] Pulse Spectroscopy System for Non-Invasive Real-Time Monitoring of the Heart Beat Volume
    Andruschenko, S.
    Timm, U.
    Hinz, M.
    Koball, S.
    Kraitl, J.
    Lewis, E.
    Ewald, H.
    2010 IEEE SENSORS, 2010, : 1863 - 1868
  • [48] Real-Time Breath Rate Monitor based Health Security System using Non-invasive Biosensor
    Bose, Sumanta
    Prabu, K.
    Kumar, D. Sriram
    2012 THIRD INTERNATIONAL CONFERENCE ON COMPUTING COMMUNICATION & NETWORKING TECHNOLOGIES (ICCCNT), 2012,
  • [49] A PILOT STUDY OF A NON-INVASIVE REAL-TIME OPTICAL BACKSCATTER PROBE IN LIVER TRANSPLANTATION
    Richards, James
    Fedotovs, Arturs
    Butler, Andrew
    Watson, Christopher
    Robertson, Paul
    TRANSPLANT INTERNATIONAL, 2021, 34 : 328 - 328
  • [50] Clinical impact of multi-parameter continuous non-invasive monitoring in hospital wards: a systematic review and meta-analysis
    Sun, Lin
    Joshi, Meera
    Khan, Sadia N.
    Ashrafian, Hutan
    Darzi, Ara
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 2020, 113 (06) : 217 - 224