Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate

被引:123
|
作者
Aharwal, K. R. [2 ]
Gandhi, Bhupendra K. [1 ]
Saini, J. S. [3 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, UA, India
[2] Shri GS Inst Technol & Sci, Dept Mech Engn, Indore 452003, Madhya Pradesh, India
[3] Deharadun Inst Technol, Dehra Dun, UA, India
关键词
Artificial roughness; Relative gap position; Relative gap width; Reynolds number; Nusselt number; Friction factor; ROUGHNESS; FLOW; GAP;
D O I
10.1016/j.ijheatmasstransfer.2009.05.032
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of artificial roughness in a solar air heater duct has been proposed to be an excellent option to enhance the heat transfer from absorber plate to the air. This paper presents an experimental investigation on heat transfer and friction characteristics of solar air heater ducts with integral repeated discrete square ribs on the absorber plate. The effect of geometrical parameters, especially, the gap width and gap position has been investigated. The roughened duct has a width to height ratio (W/H) of 5.83. The relative gap position (d/W) and relative gap width (g/e) has been varied from 0.16 to 0.5 and 0.5-2.0, respectively. Experiments have been carried out for the range of Reynolds number from 3000 to 18,000 with the relative roughness pitch (P/e) range of 4-10; relative roughness height (e/D) range of 0.018-0.037; and angle of attack (a) range of 30-90 degrees. The optimum values of parameters for rib arrangement have been obtained and discussed. For Nusselt number, the maximum enhancement of the order of 2.83 times of the corresponding value of the smooth duct has been obtained, however, the friction factor has also been seen to increase by 3.60 times of that of the smooth duct. The maximum enhancement is observed at a relative gap position of 0.25 for relative gap width of 1.0, relative roughness pitch of 8.0, angle of attack of 60 degrees and relative roughness height of 0.037. Based on the experimental data, correlations for Nusselt number and friction factor have been developed as function of roughness parameters of inclined discrete square ribs and flow Reynolds number. (C) 2009 Published by Elsevier Ltd.
引用
收藏
页码:5970 / 5977
页数:8
相关论文
共 50 条
  • [21] Heat Transfer and Friction Factor Study of a Solar Air Heater Having Multiple Arcs with Gap-Shaped Roughness Element on Absorber Plate
    Pandey, Navneet Kumar
    Bajpai, V. K.
    Varun
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (11) : 4517 - 4530
  • [22] Heat Transfer and Friction Factor Study of a Solar Air Heater Having Multiple Arcs with Gap-Shaped Roughness Element on Absorber Plate
    Navneet Kumar Pandey
    V. K. Bajpai
    Arabian Journal for Science and Engineering, 2016, 41 : 4517 - 4530
  • [23] Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate
    Lanjewar, Atul
    Bhagoria, J. L.
    Sarviya, R. M.
    ENERGY, 2011, 36 (07) : 4531 - 4541
  • [24] Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate
    Momin, AME
    Saini, JS
    Solanki, SC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (16) : 3383 - 3396
  • [25] Heat transfer and friction correlations for artificially roughened solar air heater duct with discrete W-shaped ribs
    Kumar, Arvind
    Bhagoria, J. L.
    Sarviya, R. M.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (08) : 2106 - 2117
  • [26] Heat transfer and friction factor correlations for an impinging air jets solar thermal collector with arc ribs on an absorber plate
    Kumar, Raj
    Nadda, Rahul
    Kumar, Sushil
    Kumar, Khusmeet
    Afzal, Asif
    Razak, R. K. Abdul
    Sharifpur, Mohsen
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47
  • [27] Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate
    Bhagoria, JL
    Saini, JS
    Solanki, SC
    RENEWABLE ENERGY, 2002, 25 (03) : 341 - 369
  • [28] Heat Transfer and Friction Characteristics of an Artificially Roughened Solar Air Heater
    Prasad, Rakesh
    Yadav, Anil Singh
    Singh, Nishant K.
    Johari, Dilip
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 613 - 626
  • [29] Heat transfer and friction characteristics of impinging jet solar air heater
    Chauhan, Ranchan
    Thakur, N. S.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (04)
  • [30] Heat transmission and air flow friction in a solar air heater with a ribbed absorber plate: A computational study
    Alsaiari, Abdulmohsen O.
    Iqbal, Ahamed
    Abdulkhair, Hani
    Gzara, Lassaad
    Almatrafi, Eydhah
    Alzahrani, Hassan A. H.
    Madhukeshwara, N.
    Prasanna, B. M.
    Aljohani, Maha