Stump classification was correlated with retear in the suture-bridge and double-row repair techniques for arthroscopic rotator cuff repair

被引:5
|
作者
Takeuchi, Naohide [1 ]
Kozono, Naoya [1 ]
Nishii, Akihiro [2 ]
Matsuura, Koumei [3 ]
Ishitani, Eiichi [4 ]
Onizuka, Toshihiro [5 ]
Zaitsu, Yoshihisa [6 ]
Okada, Takamitsu [7 ]
Mizuki, Yasuhiro [8 ]
Kimura, Takehiro [9 ]
Yuge, Hidehiko [6 ]
Uchimura, Taiki [8 ]
Iura, Kunio [10 ]
Mori, Tatsuya [5 ]
Ueda, Koki [8 ]
Miake, Go [5 ]
Senju, Takahiro [8 ]
Takagishi, Kenji [11 ]
Nakashima, Yasuharu [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[2] Kitakyushu Municipal Med Ctr, Dept Orthopaed Surg, Kitakyushu, Fukuoka 8020077, Japan
[3] Saiseikai Yahata Gen Hosp, Dept Orthopaed Surg, Kitakyushu, Fukuoka 8050050, Japan
[4] Fukuoka Shion Hosp, Dept Orthopaed Surg, Fukuoka 8380101, Japan
[5] Kyushu Rosai Hosp, Dept Orthopaed Surg, Kitakyushu, Fukuoka 8000296, Japan
[6] Mizoguchi Orthopaed Hosp, Dept Orthopaed Surg, Fukuoka, Fukuoka 8100001, Japan
[7] Nakabaru Hosp, Dept Orthopaed Surg, Fukuoka 8112233, Japan
[8] Sasebo Kyosai Hosp, Dept Orthopaed Surg, Fukuoka 8570879, Japan
[9] Morooka Orthopaed Hosp, Dept Orthopaed Surg, Fukuoka 8111201, Japan
[10] Fukuoka Orthopaed Hosp, Dept Orthopaed Surg, Fukuoka, Fukuoka 8150063, Japan
[11] Sada Hosp, Dept Orthopaed Surg, Fukuoka, Fukuoka 8100004, Japan
关键词
Arthroscopic rotator cuff tear; Stump classification; Retear; Risk factor;
D O I
10.1007/s00167-020-06415-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The Stump classification is significantly correlated with a retear after arthroscopic rotator cuff repair. However, no study has evaluated whether or not the stump classification is correlated with retear in the suture-bridge or double-row repair techniques. The aim of this study was to evaluate the relationship between a retear and the stump classification in the suture-bridge and double-row repair techniques. Methods Among 389 patients who underwent arthroscopic repairs of full-thickness rotator cuff tears using suture-bridge or double-row repair techniques, 326 patients (median age 67.0 years; range 25-85) were included. There were 51 small, 172 medium, 83 large, and 20 massive tears. Two hundred forty patients were treated with the suture-bridge technique, and 86 patients were treated with the double-row technique. The following variables were analyzed: age, sex, the Cofield classification, anteroposterior and mediolateral tear size on preoperative MRI, global fatty degeneration index, and the stump classification. Cuff integrity was evaluated on magnetic resonance imaging at 6 months after surgery. The patients were divided into the intact and retear groups and the relationship between the variables and retear was evaluated by multivariate logistic regression analysis. Results The overall retear rate was 10.1%. In the multivariate logistic regression analysis, the independent predictors of a retear were the stump classification type 3 (Odds ratio: 4.71, p = 0.0246), global fatty degeneration index (Odds ratio: 3.87, p = 0.0030), and anteroposterior tear size (Odds ratio: 1.07, p = 0.0077) in the suture bridge technique. In the double-row technique, the independent predictors of retear were stump classification type 3 (Odds ratio: 7.82, p = 0.0348), and age (Odds ratio: 1.22, p = 0.0163). Conclusion The stump classification was significantly correlated with retear in the suture-bridge and double-row repair technique. Stump classification type 3 was indicated to be an important risk factor for predicting retear.
引用
收藏
页码:2587 / 2594
页数:8
相关论文
共 50 条
  • [21] Suture-bridge vs. Independent Double-row Techniques in Rotator Cuff Tears
    Ladermann, Alexandre
    Chiu, Joe
    SWISS MEDICAL WEEKLY, 2023, 153 : 59S - 60S
  • [22] Functional and Structural Outcomes of Single-Row Versus Double-Row Versus Combined Double-Row and Suture-Bridge Repair for Rotator Cuff Tears
    Mihata, Teruhisa
    Watanabe, Chisato
    Fukunishi, Kunimoto
    Ohue, Mutsumi
    Tsujimura, Tomoyuki
    Fujiwara, Kenta
    Kinoshita, Mitsuo
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10): : 2091 - 2098
  • [23] Arthroscopic single-row versus double-row suture anchor rotator cuff repair
    Mazzocca, AD
    Millett, PJ
    Guanche, CA
    Santangelo, SA
    Arciero, RA
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (12): : 1861 - 1868
  • [24] Magnetic resonance imaging for relationship between the severity of perianchor fluid collection and rotator cuff integrity after arthroscopic double-row suture-bridge rotator cuff repair
    Rhee, Sung Min
    Kim, Dong Hyun
    Kim, Myung Seo
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (05)
  • [25] Double-row Labral Repair: Knotless Suture-bridge Technique
    Jiang, Kevin N.
    Byram, Ian R.
    Hsu, Stephanie H.
    Ahmad, Christopher S.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2012, 13 (03): : 107 - 110
  • [26] Biomechanical comparison between single-row with triple-loaded suture anchor and suture-bridge double-row rotator cuff repair
    He, He-Bei
    Hu, Yong
    Li, Chuan
    Li, Cheng-Guo
    Wang, Min-Cong
    Zhu, Hui-Feng
    Yan, Zhi-Wen
    Pan, Cheng-Long
    Wang, Tao
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01) : 629
  • [27] Arthroscopic double-row repair of full-thickness rotator cuff tears using a suture bridge technique
    Bales, Chris
    Anderson, Kyle
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2007, 15 (03) : 144 - 149
  • [28] Biomechanical comparison between single-row with triple-loaded suture anchor and suture-bridge double-row rotator cuff repair
    He-Bei He
    Yong Hu
    Chuan Li
    Cheng-Guo Li
    Min-Cong Wang
    Hui-Feng Zhu
    Zhi-Wen Yan
    Cheng-Long Pan
    Tao Wang
    BMC Musculoskeletal Disorders, 21
  • [29] Arthroscopic Double-Row Rotator Cuff Repair With Biceps Augmentation
    Mundakkal, Arun
    Panakkal, Jiss Joseph
    Nair, Ayyappan V.
    Ahammad, Siyad
    Meleppuram, Jimmy Joseph
    Khan, Prince Shanavas
    ARTHROSCOPY TECHNIQUES, 2024, 13 (02):
  • [30] Incidence of Retear With Double-Row Versus Single-Row Rotator Cuff Repair
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    ORTHOPEDICS, 2014, 37 (11) : E1006 - E1013